Core Equipment Vocabulary
This vocabulary is describing the core equipment profile from IEC 61970-600-2.
URI: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
Name: CoreEquipmentProfile
Classes
Class | Description |
---|---|
ActivePower | Product of RMS value of the voltage and the RMS value of the in-phase compone... |
ActivePowerPerCurrentFlow | Active power variation with current flow |
ActivePowerPerFrequency | Active power variation with frequency |
AngleDegrees | Measurement of angle in degrees |
ApparentPower | Product of the RMS value of the voltage and the RMS value of the current |
Capacitance | Capacitive part of reactance (imaginary part of impedance), at rated frequenc... |
Conductance | Factor by which voltage must be multiplied to give corresponding power lost f... |
CurrentFlow | Electrical current with sign convention: positive flow is out of the conducti... |
CurveData | Multi-purpose data points for defining a curve |
Frequency | Cycles per second |
IdentifiedObject | This is a root class to provide common identification for all classes needing... |
ACDCTerminal | An electrical connection point (AC or DC) to a piece of conducting equipment |
DCBaseTerminal | An electrical connection point at a piece of DC conducting equipment |
ACDCConverterDCTerminal | A DC electrical connection point at the AC/DC converter |
DCTerminal | An electrical connection point to generic DC conducting equipment |
Terminal | An AC electrical connection point to a piece of conducting equipment |
BaseVoltage | Defines a system base voltage which is referenced |
BasicIntervalSchedule | Schedule of values at points in time |
RegularIntervalSchedule | The schedule has time points where the time between them is constant |
SeasonDayTypeSchedule | A time schedule covering a 24 hour period, with curve data for a specific typ... |
ConformLoadSchedule | A curve of load versus time (X-axis) showing the active power values (Y1-axi... |
NonConformLoadSchedule | An active power (Y1-axis) and reactive power (Y2-axis) schedule (curves) vers... |
RegulationSchedule | A pre-established pattern over time for a controlled variable, e |
SwitchSchedule | A schedule of switch positions |
TapSchedule | A pre-established pattern over time for a tap step |
BusNameMarker | Used to apply user standard names to TopologicalNodes |
ConnectivityNode | Connectivity nodes are points where terminals of AC conducting equipment are ... |
ControlAreaGeneratingUnit | A control area generating unit |
Curve | A multi-purpose curve or functional relationship between an independent varia... |
GrossToNetActivePowerCurve | Relationship between the generating unit's gross active power output on the X... |
ReactiveCapabilityCurve | Reactive power rating envelope versus the synchronous machine's active power,... |
VsCapabilityCurve | The P-Q capability curve for a voltage source converter, with P on X-axis and... |
DayType | Group of similar days |
DCNode | DC nodes are points where terminals of DC conducting equipment are connected ... |
EnergyArea | Describes an area having energy production or consumption |
LoadArea | The class is the root or first level in a hierarchical structure for grouping... |
SubLoadArea | The class is the second level in a hierarchical structure for grouping of loa... |
EnergySchedulingType | Used to define the type of generation for scheduling purposes |
FossilFuel | The fossil fuel consumed by the non-nuclear thermal generating unit |
GeographicalRegion | A geographical region of a power system network model |
LoadGroup | The class is the third level in a hierarchical structure for grouping of load... |
ConformLoadGroup | A group of loads conforming to an allocation pattern |
NonConformLoadGroup | Loads that do not follow a daily and seasonal load variation pattern |
LoadResponseCharacteristic | Models the characteristic response of the load demand due to changes in syste... |
OperationalLimit | A value and normal value associated with a specific kind of limit |
ActivePowerLimit | Limit on active power flow |
ApparentPowerLimit | Apparent power limit |
CurrentLimit | Operational limit on current |
VoltageLimit | Operational limit applied to voltage |
OperationalLimitSet | A set of limits associated with equipment |
OperationalLimitType | The operational meaning of a category of limits |
PhaseTapChangerTable | Describes a tabular curve for how the phase angle difference and impedance va... |
PowerSystemResource | A power system resource (PSR) can be an item of equipment such as a switch, a... |
BoundaryPoint | Designates a connection point at which one or more model authority sets shall... |
CAESPlant | Compressed air energy storage plant |
CogenerationPlant | A set of thermal generating units for the production of electrical energy and... |
CombinedCyclePlant | A set of combustion turbines and steam turbines where the exhaust heat from t... |
ConnectivityNodeContainer | A base class for all objects that may contain connectivity nodes or topologic... |
EquipmentContainer | A modelling construct to provide a root class for containing equipment |
Bay | A collection of power system resources (within a given substation) including ... |
DCEquipmentContainer | A modelling construct to provide a root class for containment of DC as well a... |
DCConverterUnit | Indivisible operative unit comprising all equipment between the point of comm... |
DCLine | Overhead lines and/or cables connecting two or more HVDC substations |
Line | Contains equipment beyond a substation belonging to a power transmission line |
Substation | A collection of equipment for purposes other than generation or utilization, ... |
VoltageLevel | A collection of equipment at one common system voltage forming a switchgear |
EquivalentNetwork | A class that groups electrical equivalents, including internal nodes, of a ne... |
ControlArea | A control area is a grouping of generating units and/or loads and a cutset of... |
Equipment | The parts of a power system that are physical devices, electronic or mechanic... |
AuxiliaryEquipment | AuxiliaryEquipment describe equipment that is not performing any primary func... |
FaultIndicator | A FaultIndicator is typically only an indicator (which may or may not be remo... |
Sensor | This class describe devices that transform a measured quantity into signals t... |
CurrentTransformer | Instrument transformer used to measure electrical qualities of the circuit th... |
PostLineSensor | A sensor used mainly in overhead distribution networks as the source of both ... |
PotentialTransformer | Instrument transformer (also known as Voltage Transformer) used to measure el... |
SurgeArrester | Shunt device, installed on the network, usually in the proximity of electrica... |
WaveTrap | Line traps are devices that impede high frequency power line carrier signals ... |
ConductingEquipment | The parts of the AC power system that are designed to carry current or that a... |
ACDCConverter | A unit with valves for three phases, together with unit control equipment, es... |
CsConverter | DC side of the current source converter (CSC) |
VsConverter | DC side of the voltage source converter (VSC) |
Clamp | A Clamp is a galvanic connection at a line segment where other equipment is c... |
Conductor | Combination of conducting material with consistent electrical characteristics... |
ACLineSegment | A wire or combination of wires, with consistent electrical characteristics, b... |
Connector | A conductor, or group of conductors, with negligible impedance, that serve to... |
BusbarSection | A conductor, or group of conductors, with negligible impedance, that serve to... |
Junction | A point where one or more conducting equipments are connected with zero resis... |
EarthFaultCompensator | A conducting equipment used to represent a connection to ground which is typi... |
GroundingImpedance | A fixed impedance device used for grounding |
PetersenCoil | A variable impedance device normally used to offset line charging during sing... |
EnergyConnection | A connection of energy generation or consumption on the power system model |
EnergyConsumer | Generic user of energy - a point of consumption on the power system model |
ConformLoad | ConformLoad represent loads that follow a daily load change pattern where the... |
NonConformLoad | NonConformLoad represents loads that do not follow a daily load change patter... |
StationSupply | Station supply with load derived from the station output |
EnergySource | A generic equivalent for an energy supplier on a transmission or distribution... |
RegulatingCondEq | A type of conducting equipment that can regulate a quantity (i |
ExternalNetworkInjection | This class represents the external network and it is used for IEC 60909 calcu... |
PowerElectronicsConnection | A connection to the AC network for energy production or consumption that uses... |
RotatingMachine | A rotating machine which may be used as a generator or motor |
AsynchronousMachine | A rotating machine whose shaft rotates asynchronously with the electrical fie... |
SynchronousMachine | An electromechanical device that operates with shaft rotating synchronously w... |
ShuntCompensator | A shunt capacitor or reactor or switchable bank of shunt capacitors or reacto... |
LinearShuntCompensator | A linear shunt compensator has banks or sections with equal admittance values |
NonlinearShuntCompensator | A non linear shunt compensator has bank or section admittance values that dif... |
StaticVarCompensator | A facility for providing variable and controllable shunt reactive power |
EquivalentEquipment | The class represents equivalent objects that are the result of a network redu... |
EquivalentBranch | The class represents equivalent branches |
EquivalentInjection | This class represents equivalent injections (generation or load) |
EquivalentShunt | The class represents equivalent shunts |
Ground | A point where the system is grounded used for connecting conducting equipment... |
PowerTransformer | An electrical device consisting of two or more coupled windings, with or wit... |
SeriesCompensator | A Series Compensator is a series capacitor or reactor or an AC transmission l... |
Switch | A generic device designed to close, or open, or both, one or more electric ci... |
Cut | A cut separates a line segment into two parts |
Disconnector | A manually operated or motor operated mechanical switching device used for ch... |
Fuse | An overcurrent protective device with a circuit opening fusible part that is ... |
GroundDisconnector | A manually operated or motor operated mechanical switching device used for is... |
Jumper | A short section of conductor with negligible impedance which can be manually ... |
ProtectedSwitch | A ProtectedSwitch is a switching device that can be operated by ProtectionEqu... |
Breaker | A mechanical switching device capable of making, carrying, and breaking curre... |
DisconnectingCircuitBreaker | A circuit breaking device including disconnecting function, eliminating the n... |
LoadBreakSwitch | A mechanical switching device capable of making, carrying, and breaking curre... |
DCConductingEquipment | The parts of the DC power system that are designed to carry current or that a... |
DCBusbar | A busbar within a DC system |
DCChopper | Low resistance equipment used in the internal DC circuit to balance voltages |
DCGround | A ground within a DC system |
DCLineSegment | A wire or combination of wires not insulated from one another, with consisten... |
DCSeriesDevice | A series device within the DC system, typically a reactor used for filtering ... |
DCShunt | A shunt device within the DC system, typically used for filtering |
DCSwitch | A switch within the DC system |
DCBreaker | A breaker within a DC system |
DCDisconnector | A disconnector within a DC system |
GeneratingUnit | A single or set of synchronous machines for converting mechanical power into ... |
HydroGeneratingUnit | A generating unit whose prime mover is a hydraulic turbine (e |
NuclearGeneratingUnit | A nuclear generating unit |
SolarGeneratingUnit | A solar thermal generating unit, connected to the grid by means of a rotating... |
ThermalGeneratingUnit | A generating unit whose prime mover could be a steam turbine, combustion turb... |
WindGeneratingUnit | A wind driven generating unit, connected to the grid by means of a rotating m... |
HydroPump | A synchronous motor-driven pump, typically associated with a pumped storage p... |
PowerElectronicsUnit | A generating unit or battery or aggregation that connects to the AC network u... |
BatteryUnit | An electrochemical energy storage device |
PhotoVoltaicUnit | A photovoltaic device or an aggregation of such devices |
PowerElectronicsWindUnit | A wind generating unit that connects to the AC network with power electronics... |
HydroPowerPlant | A hydro power station which can generate or pump |
RegulatingControl | Specifies a set of equipment that works together to control a power system qu... |
TapChangerControl | Describes behaviour specific to tap changers, e |
SolarPowerPlant | Solar power plant |
TapChanger | Mechanism for changing transformer winding tap positions |
PhaseTapChanger | A transformer phase shifting tap model that controls the phase angle differen... |
PhaseTapChangerLinear | Describes a tap changer with a linear relation between the tap step and the p... |
PhaseTapChangerNonLinear | The non-linear phase tap changer describes the non-linear behaviour of a phas... |
PhaseTapChangerAsymmetrical | Describes the tap model for an asymmetrical phase shifting transformer in whi... |
PhaseTapChangerSymmetrical | Describes a symmetrical phase shifting transformer tap model in which the vol... |
PhaseTapChangerTabular | Describes a tap changer with a table defining the relation between the tap st... |
RatioTapChanger | A tap changer that changes the voltage ratio impacting the voltage magnitude ... |
WindPowerPlant | Wind power plant |
RatioTapChangerTable | Describes a curve for how the voltage magnitude and impedance varies with the... |
ReportingGroup | A reporting group is used for various ad-hoc groupings used for reporting |
Season | A specified time period of the year |
SubGeographicalRegion | A subset of a geographical region of a power system network model |
TieFlow | Defines the structure (in terms of location and direction) of the net interch... |
TransformerEnd | A conducting connection point of a power transformer |
PowerTransformerEnd | A PowerTransformerEnd is associated with each Terminal of a PowerTransformer |
Inductance | Inductive part of reactance (imaginary part of impedance), at rated frequency |
Length | Unit of length |
Money | Amount of money |
NonlinearShuntCompensatorPoint | A non linear shunt compensator bank or section admittance value |
PerCent | Percentage on a defined base |
Reactance | Reactance (imaginary part of impedance), at rated frequency |
ReactivePower | Product of RMS value of the voltage and the RMS value of the quadrature compo... |
RealEnergy | Real electrical energy |
RegularTimePoint | Time point for a schedule where the time between the consecutive points is co... |
Resistance | Resistance (real part of impedance) |
RotationSpeed | Number of revolutions per second |
Seconds | Time, in seconds |
Susceptance | Imaginary part of admittance |
TapChangerTablePoint | Describes each tap step in the tabular curve |
PhaseTapChangerTablePoint | Describes each tap step in the phase tap changer tabular curve |
RatioTapChangerTablePoint | Describes each tap step in the ratio tap changer tabular curve |
Voltage | Electrical voltage, can be both AC and DC |
VoltagePerReactivePower | Voltage variation with reactive power |