ConformLoad
ConformLoad represent loads that follow a daily load change pattern where the pattern can be used to scale the load with a system load.
URI: cim:ConformLoad
Type: Class
classDiagram
class ConformLoad
click ConformLoad href "../ConformLoad"
EnergyConsumer <|-- ConformLoad
click EnergyConsumer href "../EnergyConsumer"
ConformLoad : Equipment.aggregate
ConformLoad : ConductingEquipment.BaseVoltage
ConformLoad --> BaseVoltage : ConductingEquipment.BaseVoltage
click BaseVoltage href "../BaseVoltage"
ConformLoad : IdentifiedObject.description
ConformLoad : IdentifiedObject.energyIdentCodeEic
ConformLoad : Equipment.EquipmentContainer
ConformLoad --> EquipmentContainer : Equipment.EquipmentContainer
click EquipmentContainer href "../EquipmentContainer"
ConformLoad : ConformLoad.LoadGroup
ConformLoad --> ConformLoadGroup : ConformLoad.LoadGroup
click ConformLoadGroup href "../ConformLoadGroup"
ConformLoad : EnergyConsumer.LoadResponse
ConformLoad --> LoadResponseCharacteristic : EnergyConsumer.LoadResponse
click LoadResponseCharacteristic href "../LoadResponseCharacteristic"
ConformLoad : IdentifiedObject.mRID
ConformLoad : IdentifiedObject.name
ConformLoad : Equipment.normallyInService
ConformLoad : Equipment.OperationalLimitSet
ConformLoad --> OperationalLimitSet : Equipment.OperationalLimitSet
click OperationalLimitSet href "../OperationalLimitSet"
ConformLoad : EnergyConsumer.pfixed
ConformLoad --> ActivePower : EnergyConsumer.pfixed
click ActivePower href "../ActivePower"
ConformLoad : EnergyConsumer.pfixedPct
ConformLoad --> PerCent : EnergyConsumer.pfixedPct
click PerCent href "../PerCent"
ConformLoad : EnergyConsumer.qfixed
ConformLoad --> ReactivePower : EnergyConsumer.qfixed
click ReactivePower href "../ReactivePower"
ConformLoad : EnergyConsumer.qfixedPct
ConformLoad --> PerCent : EnergyConsumer.qfixedPct
click PerCent href "../PerCent"
ConformLoad : IdentifiedObject.shortName
ConformLoad : ConductingEquipment.Terminals
ConformLoad --> Terminal : ConductingEquipment.Terminals
click Terminal href "../Terminal"
Inheritance
Attributes
Name | URI | Cardinality and Range | Description | Inheritance |
---|---|---|---|---|
LoadGroup | cim:ConformLoad.LoadGroup | 1 ConformLoadGroup |
Group of this ConformLoad | direct |
pfixed | cim:EnergyConsumer.pfixed | 0..1 ActivePower |
Active power of the load that is a fixed quantity and does not vary as load g... | EnergyConsumer |
pfixedPct | cim:EnergyConsumer.pfixedPct | 0..1 PerCent |
Fixed active power as a percentage of load group fixed active power | EnergyConsumer |
qfixed | cim:EnergyConsumer.qfixed | 0..1 ReactivePower |
Reactive power of the load that is a fixed quantity and does not vary as load... | EnergyConsumer |
qfixedPct | cim:EnergyConsumer.qfixedPct | 0..1 PerCent |
Fixed reactive power as a percentage of load group fixed reactive power | EnergyConsumer |
LoadResponse | cim:EnergyConsumer.LoadResponse | 0..1 LoadResponseCharacteristic |
The load response characteristic of this load | EnergyConsumer |
BaseVoltage | cim:ConductingEquipment.BaseVoltage | 0..1 BaseVoltage |
Base voltage of this conducting equipment | ConductingEquipment |
Terminals | cim:ConductingEquipment.Terminals | * Terminal |
Conducting equipment have terminals that may be connected to other conducting... | ConductingEquipment |
aggregate | cim:Equipment.aggregate | 0..1 boolean |
The aggregate flag provides an alternative way of representing an aggregated ... | Equipment |
normallyInService | cim:Equipment.normallyInService | 0..1 boolean |
Specifies the availability of the equipment under normal operating conditions | Equipment |
EquipmentContainer | cim:Equipment.EquipmentContainer | 0..1 EquipmentContainer |
Container of this equipment | Equipment |
OperationalLimitSet | cim:Equipment.OperationalLimitSet | * OperationalLimitSet |
The operational limit sets associated with this equipment | Equipment |
description | cim:IdentifiedObject.description | 0..1 string |
The description is a free human readable text describing or naming the object | IdentifiedObject |
energyIdentCodeEic | eu:IdentifiedObject.energyIdentCodeEic | 0..1 string |
The attribute is used for an exchange of the EIC code (Energy identification ... | IdentifiedObject |
mRID | cim:IdentifiedObject.mRID | 1 string |
Master resource identifier issued by a model authority | IdentifiedObject |
name | cim:IdentifiedObject.name | 1 string |
The name is any free human readable and possibly non unique text naming the o... | IdentifiedObject |
shortName | eu:IdentifiedObject.shortName | 0..1 string |
The attribute is used for an exchange of a human readable short name with len... | IdentifiedObject |
Usages
used by | used in | type | used |
---|---|---|---|
ConformLoadGroup | EnergyConsumers | range | ConformLoad |
Identifier and Mapping Information
Schema Source
- from schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
Mappings
Mapping Type | Mapped Value |
---|---|
self | cim:ConformLoad |
native | this:ConformLoad |