EarthFaultCompensator
A conducting equipment used to represent a connection to ground which is typically used to compensate earth faults. An earth fault compensator device modelled with a single terminal implies a second terminal solidly connected to ground. If two terminals are modelled, the ground is not assumed and normal connection rules apply.
URI: cim:EarthFaultCompensator
Type: Class
classDiagram
class EarthFaultCompensator
click EarthFaultCompensator href "../EarthFaultCompensator"
ConductingEquipment <|-- EarthFaultCompensator
click ConductingEquipment href "../ConductingEquipment"
EarthFaultCompensator <|-- GroundingImpedance
click GroundingImpedance href "../GroundingImpedance"
EarthFaultCompensator <|-- PetersenCoil
click PetersenCoil href "../PetersenCoil"
EarthFaultCompensator : Equipment.aggregate
EarthFaultCompensator : ConductingEquipment.BaseVoltage
EarthFaultCompensator --> BaseVoltage : ConductingEquipment.BaseVoltage
click BaseVoltage href "../BaseVoltage"
EarthFaultCompensator : IdentifiedObject.description
EarthFaultCompensator : IdentifiedObject.energyIdentCodeEic
EarthFaultCompensator : Equipment.EquipmentContainer
EarthFaultCompensator --> EquipmentContainer : Equipment.EquipmentContainer
click EquipmentContainer href "../EquipmentContainer"
EarthFaultCompensator : IdentifiedObject.mRID
EarthFaultCompensator : IdentifiedObject.name
EarthFaultCompensator : Equipment.normallyInService
EarthFaultCompensator : Equipment.OperationalLimitSet
EarthFaultCompensator --> OperationalLimitSet : Equipment.OperationalLimitSet
click OperationalLimitSet href "../OperationalLimitSet"
EarthFaultCompensator : IdentifiedObject.shortName
EarthFaultCompensator : ConductingEquipment.Terminals
EarthFaultCompensator --> Terminal : ConductingEquipment.Terminals
click Terminal href "../Terminal"
Inheritance
- IdentifiedObject
- PowerSystemResource
- Equipment
- ConductingEquipment
- EarthFaultCompensator
- ConductingEquipment
- Equipment
- PowerSystemResource
Attributes
Name | URI | Cardinality and Range | Description | Inheritance |
---|---|---|---|---|
BaseVoltage | cim:ConductingEquipment.BaseVoltage | 0..1 BaseVoltage |
Base voltage of this conducting equipment | ConductingEquipment |
Terminals | cim:ConductingEquipment.Terminals | * Terminal |
Conducting equipment have terminals that may be connected to other conducting... | ConductingEquipment |
aggregate | cim:Equipment.aggregate | 0..1 boolean |
The aggregate flag provides an alternative way of representing an aggregated ... | Equipment |
normallyInService | cim:Equipment.normallyInService | 0..1 boolean |
Specifies the availability of the equipment under normal operating conditions | Equipment |
EquipmentContainer | cim:Equipment.EquipmentContainer | 0..1 EquipmentContainer |
Container of this equipment | Equipment |
OperationalLimitSet | cim:Equipment.OperationalLimitSet | * OperationalLimitSet |
The operational limit sets associated with this equipment | Equipment |
description | cim:IdentifiedObject.description | 0..1 string |
The description is a free human readable text describing or naming the object | IdentifiedObject |
energyIdentCodeEic | eu:IdentifiedObject.energyIdentCodeEic | 0..1 string |
The attribute is used for an exchange of the EIC code (Energy identification ... | IdentifiedObject |
mRID | cim:IdentifiedObject.mRID | 1 string |
Master resource identifier issued by a model authority | IdentifiedObject |
name | cim:IdentifiedObject.name | 1 string |
The name is any free human readable and possibly non unique text naming the o... | IdentifiedObject |
shortName | eu:IdentifiedObject.shortName | 0..1 string |
The attribute is used for an exchange of a human readable short name with len... | IdentifiedObject |
Identifier and Mapping Information
Schema Source
- from schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
Mappings
Mapping Type | Mapped Value |
---|---|
self | cim:EarthFaultCompensator |
native | this:EarthFaultCompensator |