This class represents the external network and it is used for IEC 60909 calculations.
URI: cim:ExternalNetworkInjection
Type: Class
classDiagram
class ExternalNetworkInjection
click ExternalNetworkInjection href "../ExternalNetworkInjection"
RegulatingCondEq <|-- ExternalNetworkInjection
click RegulatingCondEq href "../RegulatingCondEq"
ExternalNetworkInjection : Equipment.aggregate
ExternalNetworkInjection : ConductingEquipment.BaseVoltage
ExternalNetworkInjection --> BaseVoltage : ConductingEquipment.BaseVoltage
click BaseVoltage href "../BaseVoltage"
ExternalNetworkInjection : IdentifiedObject.description
ExternalNetworkInjection : IdentifiedObject.energyIdentCodeEic
ExternalNetworkInjection : Equipment.EquipmentContainer
ExternalNetworkInjection --> EquipmentContainer : Equipment.EquipmentContainer
click EquipmentContainer href "../EquipmentContainer"
ExternalNetworkInjection : ExternalNetworkInjection.governorSCD
ExternalNetworkInjection --> ActivePowerPerFrequency : ExternalNetworkInjection.governorSCD
click ActivePowerPerFrequency href "../ActivePowerPerFrequency"
ExternalNetworkInjection : ExternalNetworkInjection.maxP
ExternalNetworkInjection --> ActivePower : ExternalNetworkInjection.maxP
click ActivePower href "../ActivePower"
ExternalNetworkInjection : ExternalNetworkInjection.maxQ
ExternalNetworkInjection --> ReactivePower : ExternalNetworkInjection.maxQ
click ReactivePower href "../ReactivePower"
ExternalNetworkInjection : ExternalNetworkInjection.minP
ExternalNetworkInjection --> ActivePower : ExternalNetworkInjection.minP
click ActivePower href "../ActivePower"
ExternalNetworkInjection : ExternalNetworkInjection.minQ
ExternalNetworkInjection --> ReactivePower : ExternalNetworkInjection.minQ
click ReactivePower href "../ReactivePower"
ExternalNetworkInjection : IdentifiedObject.mRID
ExternalNetworkInjection : IdentifiedObject.name
ExternalNetworkInjection : Equipment.normallyInService
ExternalNetworkInjection : Equipment.OperationalLimitSet
ExternalNetworkInjection --> OperationalLimitSet : Equipment.OperationalLimitSet
click OperationalLimitSet href "../OperationalLimitSet"
ExternalNetworkInjection : RegulatingCondEq.RegulatingControl
ExternalNetworkInjection --> RegulatingControl : RegulatingCondEq.RegulatingControl
click RegulatingControl href "../RegulatingControl"
ExternalNetworkInjection : IdentifiedObject.shortName
ExternalNetworkInjection : ConductingEquipment.Terminals
ExternalNetworkInjection --> Terminal : ConductingEquipment.Terminals
click Terminal href "../Terminal"
Inheritance
- IdentifiedObject
- PowerSystemResource
- Equipment
- ConductingEquipment
- EnergyConnection
- RegulatingCondEq
- ExternalNetworkInjection
- RegulatingCondEq
- EnergyConnection
- ConductingEquipment
- Equipment
- PowerSystemResource
Attributes
Name | URI | Cardinality and Range | Description | Inheritance |
---|---|---|---|---|
governorSCD | cim:ExternalNetworkInjection.governorSCD | 1 ActivePowerPerFrequency |
Power Frequency Bias | direct |
maxP | cim:ExternalNetworkInjection.maxP | 1 ActivePower |
Maximum active power of the injection | direct |
maxQ | cim:ExternalNetworkInjection.maxQ | 1 ReactivePower |
Maximum reactive power limit | direct |
minP | cim:ExternalNetworkInjection.minP | 1 ActivePower |
Minimum active power of the injection | direct |
minQ | cim:ExternalNetworkInjection.minQ | 1 ReactivePower |
Minimum reactive power limit | direct |
RegulatingControl | cim:RegulatingCondEq.RegulatingControl | 0..1 RegulatingControl |
The regulating control scheme in which this equipment participates | RegulatingCondEq |
BaseVoltage | cim:ConductingEquipment.BaseVoltage | 0..1 BaseVoltage |
Base voltage of this conducting equipment | ConductingEquipment |
Terminals | cim:ConductingEquipment.Terminals | * Terminal |
Conducting equipment have terminals that may be connected to other conducting... | ConductingEquipment |
aggregate | cim:Equipment.aggregate | 0..1 boolean |
The aggregate flag provides an alternative way of representing an aggregated ... | Equipment |
normallyInService | cim:Equipment.normallyInService | 0..1 boolean |
Specifies the availability of the equipment under normal operating conditions | Equipment |
EquipmentContainer | cim:Equipment.EquipmentContainer | 0..1 EquipmentContainer |
Container of this equipment | Equipment |
OperationalLimitSet | cim:Equipment.OperationalLimitSet | * OperationalLimitSet |
The operational limit sets associated with this equipment | Equipment |
description | cim:IdentifiedObject.description | 0..1 string |
The description is a free human readable text describing or naming the object | IdentifiedObject |
energyIdentCodeEic | eu:IdentifiedObject.energyIdentCodeEic | 0..1 string |
The attribute is used for an exchange of the EIC code (Energy identification ... | IdentifiedObject |
mRID | cim:IdentifiedObject.mRID | 1 string |
Master resource identifier issued by a model authority | IdentifiedObject |
name | cim:IdentifiedObject.name | 1 string |
The name is any free human readable and possibly non unique text naming the o... | IdentifiedObject |
shortName | eu:IdentifiedObject.shortName | 0..1 string |
The attribute is used for an exchange of a human readable short name with len... | IdentifiedObject |
Identifier and Mapping Information
Schema Source
- from schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
Mappings
Mapping Type | Mapped Value |
---|---|
self | cim:ExternalNetworkInjection |