HydroGeneratingUnit
A generating unit whose prime mover is a hydraulic turbine (e.g., Francis, Pelton, Kaplan).
URI: cim:HydroGeneratingUnit
Type: Class
classDiagram
class HydroGeneratingUnit
click HydroGeneratingUnit href "../HydroGeneratingUnit"
GeneratingUnit <|-- HydroGeneratingUnit
click GeneratingUnit href "../GeneratingUnit"
HydroGeneratingUnit : Equipment.aggregate
HydroGeneratingUnit : GeneratingUnit.ControlAreaGeneratingUnit
HydroGeneratingUnit --> ControlAreaGeneratingUnit : GeneratingUnit.ControlAreaGeneratingUnit
click ControlAreaGeneratingUnit href "../ControlAreaGeneratingUnit"
HydroGeneratingUnit : IdentifiedObject.description
HydroGeneratingUnit : HydroGeneratingUnit.dropHeight
HydroGeneratingUnit --> Length : HydroGeneratingUnit.dropHeight
click Length href "../Length"
HydroGeneratingUnit : HydroGeneratingUnit.energyConversionCapability
HydroGeneratingUnit --> HydroEnergyConversionKind : HydroGeneratingUnit.energyConversionCapability
click HydroEnergyConversionKind href "../HydroEnergyConversionKind"
HydroGeneratingUnit : IdentifiedObject.energyIdentCodeEic
HydroGeneratingUnit : Equipment.EquipmentContainer
HydroGeneratingUnit --> EquipmentContainer : Equipment.EquipmentContainer
click EquipmentContainer href "../EquipmentContainer"
HydroGeneratingUnit : GeneratingUnit.genControlSource
HydroGeneratingUnit --> GeneratorControlSource : GeneratingUnit.genControlSource
click GeneratorControlSource href "../GeneratorControlSource"
HydroGeneratingUnit : GeneratingUnit.governorSCD
HydroGeneratingUnit --> PerCent : GeneratingUnit.governorSCD
click PerCent href "../PerCent"
HydroGeneratingUnit : GeneratingUnit.GrossToNetActivePowerCurves
HydroGeneratingUnit --> GrossToNetActivePowerCurve : GeneratingUnit.GrossToNetActivePowerCurves
click GrossToNetActivePowerCurve href "../GrossToNetActivePowerCurve"
HydroGeneratingUnit : HydroGeneratingUnit.HydroPowerPlant
HydroGeneratingUnit --> HydroPowerPlant : HydroGeneratingUnit.HydroPowerPlant
click HydroPowerPlant href "../HydroPowerPlant"
HydroGeneratingUnit : GeneratingUnit.longPF
HydroGeneratingUnit : GeneratingUnit.maximumAllowableSpinningReserve
HydroGeneratingUnit --> ActivePower : GeneratingUnit.maximumAllowableSpinningReserve
click ActivePower href "../ActivePower"
HydroGeneratingUnit : GeneratingUnit.maxOperatingP
HydroGeneratingUnit --> ActivePower : GeneratingUnit.maxOperatingP
click ActivePower href "../ActivePower"
HydroGeneratingUnit : GeneratingUnit.minOperatingP
HydroGeneratingUnit --> ActivePower : GeneratingUnit.minOperatingP
click ActivePower href "../ActivePower"
HydroGeneratingUnit : IdentifiedObject.mRID
HydroGeneratingUnit : IdentifiedObject.name
HydroGeneratingUnit : GeneratingUnit.nominalP
HydroGeneratingUnit --> ActivePower : GeneratingUnit.nominalP
click ActivePower href "../ActivePower"
HydroGeneratingUnit : Equipment.normallyInService
HydroGeneratingUnit : Equipment.OperationalLimitSet
HydroGeneratingUnit --> OperationalLimitSet : Equipment.OperationalLimitSet
click OperationalLimitSet href "../OperationalLimitSet"
HydroGeneratingUnit : GeneratingUnit.ratedGrossMaxP
HydroGeneratingUnit --> ActivePower : GeneratingUnit.ratedGrossMaxP
click ActivePower href "../ActivePower"
HydroGeneratingUnit : GeneratingUnit.ratedGrossMinP
HydroGeneratingUnit --> ActivePower : GeneratingUnit.ratedGrossMinP
click ActivePower href "../ActivePower"
HydroGeneratingUnit : GeneratingUnit.ratedNetMaxP
HydroGeneratingUnit --> ActivePower : GeneratingUnit.ratedNetMaxP
click ActivePower href "../ActivePower"
HydroGeneratingUnit : GeneratingUnit.RotatingMachine
HydroGeneratingUnit --> RotatingMachine : GeneratingUnit.RotatingMachine
click RotatingMachine href "../RotatingMachine"
HydroGeneratingUnit : IdentifiedObject.shortName
HydroGeneratingUnit : GeneratingUnit.shortPF
HydroGeneratingUnit : GeneratingUnit.startupCost
HydroGeneratingUnit --> Money : GeneratingUnit.startupCost
click Money href "../Money"
HydroGeneratingUnit : GeneratingUnit.startupTime
HydroGeneratingUnit --> Seconds : GeneratingUnit.startupTime
click Seconds href "../Seconds"
HydroGeneratingUnit : GeneratingUnit.totalEfficiency
HydroGeneratingUnit --> PerCent : GeneratingUnit.totalEfficiency
click PerCent href "../PerCent"
HydroGeneratingUnit : HydroGeneratingUnit.turbineType
HydroGeneratingUnit --> HydroTurbineKind : HydroGeneratingUnit.turbineType
click HydroTurbineKind href "../HydroTurbineKind"
HydroGeneratingUnit : GeneratingUnit.variableCost
HydroGeneratingUnit --> Money : GeneratingUnit.variableCost
click Money href "../Money"
Inheritance
- IdentifiedObject
- PowerSystemResource
- Equipment
- GeneratingUnit
- HydroGeneratingUnit
- GeneratingUnit
- Equipment
- PowerSystemResource
Attributes
Name | URI | Cardinality and Range | Description | Inheritance |
---|---|---|---|---|
energyConversionCapability | cim:HydroGeneratingUnit.energyConversionCapability | 0..1 HydroEnergyConversionKind |
Energy conversion capability for generating | direct |
dropHeight | cim:HydroGeneratingUnit.dropHeight | 0..1 Length |
The height water drops from the reservoir mid-point to the turbine | direct |
turbineType | cim:HydroGeneratingUnit.turbineType | 0..1 HydroTurbineKind |
Type of turbine | direct |
HydroPowerPlant | cim:HydroGeneratingUnit.HydroPowerPlant | 0..1 HydroPowerPlant |
The hydro generating unit belongs to a hydro power plant | direct |
ControlAreaGeneratingUnit | cim:GeneratingUnit.ControlAreaGeneratingUnit | * ControlAreaGeneratingUnit |
ControlArea specifications for this generating unit | GeneratingUnit |
genControlSource | cim:GeneratingUnit.genControlSource | 0..1 GeneratorControlSource |
The source of controls for a generating unit | GeneratingUnit |
governorSCD | cim:GeneratingUnit.governorSCD | 0..1 PerCent |
Governor Speed Changer Droop | GeneratingUnit |
longPF | cim:GeneratingUnit.longPF | 0..1 float |
Generating unit long term economic participation factor | GeneratingUnit |
maximumAllowableSpinningReserve | cim:GeneratingUnit.maximumAllowableSpinningReserve | 0..1 ActivePower |
Maximum allowable spinning reserve | GeneratingUnit |
maxOperatingP | cim:GeneratingUnit.maxOperatingP | 1 ActivePower |
This is the maximum operating active power limit the dispatcher can enter for... | GeneratingUnit |
minOperatingP | cim:GeneratingUnit.minOperatingP | 1 ActivePower |
This is the minimum operating active power limit the dispatcher can enter for... | GeneratingUnit |
nominalP | cim:GeneratingUnit.nominalP | 0..1 ActivePower |
The nominal power of the generating unit | GeneratingUnit |
ratedGrossMaxP | cim:GeneratingUnit.ratedGrossMaxP | 0..1 ActivePower |
The unit's gross rated maximum capacity (book value) | GeneratingUnit |
ratedGrossMinP | cim:GeneratingUnit.ratedGrossMinP | 0..1 ActivePower |
The gross rated minimum generation level which the unit can safely operate at... | GeneratingUnit |
ratedNetMaxP | cim:GeneratingUnit.ratedNetMaxP | 0..1 ActivePower |
The net rated maximum capacity determined by subtracting the auxiliary power ... | GeneratingUnit |
shortPF | cim:GeneratingUnit.shortPF | 0..1 float |
Generating unit short term economic participation factor | GeneratingUnit |
startupCost | cim:GeneratingUnit.startupCost | 0..1 Money |
The initial startup cost incurred for each start of the GeneratingUnit | GeneratingUnit |
variableCost | cim:GeneratingUnit.variableCost | 0..1 Money |
The variable cost component of production per unit of ActivePower | GeneratingUnit |
startupTime | cim:GeneratingUnit.startupTime | 0..1 Seconds |
Time it takes to get the unit on-line, from the time that the prime mover mec... | GeneratingUnit |
totalEfficiency | cim:GeneratingUnit.totalEfficiency | 0..1 PerCent |
The efficiency of the unit in converting the fuel into electrical energy | GeneratingUnit |
GrossToNetActivePowerCurves | cim:GeneratingUnit.GrossToNetActivePowerCurves | * GrossToNetActivePowerCurve |
A generating unit may have a gross active power to net active power curve, de... | GeneratingUnit |
RotatingMachine | cim:GeneratingUnit.RotatingMachine | 1..* RotatingMachine |
A synchronous machine may operate as a generator and as such becomes a member... | GeneratingUnit |
aggregate | cim:Equipment.aggregate | 0..1 boolean |
The aggregate flag provides an alternative way of representing an aggregated ... | Equipment |
normallyInService | cim:Equipment.normallyInService | 0..1 boolean |
Specifies the availability of the equipment under normal operating conditions | Equipment |
EquipmentContainer | cim:Equipment.EquipmentContainer | 0..1 EquipmentContainer |
Container of this equipment | Equipment |
OperationalLimitSet | cim:Equipment.OperationalLimitSet | * OperationalLimitSet |
The operational limit sets associated with this equipment | Equipment |
description | cim:IdentifiedObject.description | 0..1 string |
The description is a free human readable text describing or naming the object | IdentifiedObject |
energyIdentCodeEic | eu:IdentifiedObject.energyIdentCodeEic | 0..1 string |
The attribute is used for an exchange of the EIC code (Energy identification ... | IdentifiedObject |
mRID | cim:IdentifiedObject.mRID | 1 string |
Master resource identifier issued by a model authority | IdentifiedObject |
name | cim:IdentifiedObject.name | 1 string |
The name is any free human readable and possibly non unique text naming the o... | IdentifiedObject |
shortName | eu:IdentifiedObject.shortName | 0..1 string |
The attribute is used for an exchange of a human readable short name with len... | IdentifiedObject |
Usages
used by | used in | type | used |
---|---|---|---|
HydroPowerPlant | HydroGeneratingUnits | range | HydroGeneratingUnit |
Identifier and Mapping Information
Schema Source
- from schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
Mappings
Mapping Type | Mapped Value |
---|---|
self | cim:HydroGeneratingUnit |
native | this:HydroGeneratingUnit |