Jumper
A short section of conductor with negligible impedance which can be manually removed and replaced if the circuit is de-energized. Note that zero-impedance branches can potentially be modelled by other equipment types.
URI: cim:Jumper
Type: Class
classDiagram
class Jumper
click Jumper href "../Jumper"
Switch <|-- Jumper
click Switch href "../Switch"
Jumper : Equipment.aggregate
Jumper : ConductingEquipment.BaseVoltage
Jumper --> BaseVoltage : ConductingEquipment.BaseVoltage
click BaseVoltage href "../BaseVoltage"
Jumper : IdentifiedObject.description
Jumper : IdentifiedObject.energyIdentCodeEic
Jumper : Equipment.EquipmentContainer
Jumper --> EquipmentContainer : Equipment.EquipmentContainer
click EquipmentContainer href "../EquipmentContainer"
Jumper : IdentifiedObject.mRID
Jumper : IdentifiedObject.name
Jumper : Equipment.normallyInService
Jumper : Switch.normalOpen
Jumper : Equipment.OperationalLimitSet
Jumper --> OperationalLimitSet : Equipment.OperationalLimitSet
click OperationalLimitSet href "../OperationalLimitSet"
Jumper : Switch.ratedCurrent
Jumper --> CurrentFlow : Switch.ratedCurrent
click CurrentFlow href "../CurrentFlow"
Jumper : Switch.retained
Jumper : IdentifiedObject.shortName
Jumper : Switch.SwitchSchedules
Jumper --> SwitchSchedule : Switch.SwitchSchedules
click SwitchSchedule href "../SwitchSchedule"
Jumper : ConductingEquipment.Terminals
Jumper --> Terminal : ConductingEquipment.Terminals
click Terminal href "../Terminal"
Inheritance
Attributes
Name | URI | Cardinality and Range | Description | Inheritance |
---|---|---|---|---|
normalOpen | cim:Switch.normalOpen | 1 boolean |
The attribute is used in cases when no Measurement for the status value is pr... | Switch |
ratedCurrent | cim:Switch.ratedCurrent | 0..1 CurrentFlow |
The maximum continuous current carrying capacity in amps governed by the devi... | Switch |
retained | cim:Switch.retained | 1 boolean |
Branch is retained in the topological solution | Switch |
SwitchSchedules | cim:Switch.SwitchSchedules | * SwitchSchedule |
A Switch can be associated with SwitchSchedules | Switch |
BaseVoltage | cim:ConductingEquipment.BaseVoltage | 0..1 BaseVoltage |
Base voltage of this conducting equipment | ConductingEquipment |
Terminals | cim:ConductingEquipment.Terminals | * Terminal |
Conducting equipment have terminals that may be connected to other conducting... | ConductingEquipment |
aggregate | cim:Equipment.aggregate | 0..1 boolean |
The aggregate flag provides an alternative way of representing an aggregated ... | Equipment |
normallyInService | cim:Equipment.normallyInService | 0..1 boolean |
Specifies the availability of the equipment under normal operating conditions | Equipment |
EquipmentContainer | cim:Equipment.EquipmentContainer | 0..1 EquipmentContainer |
Container of this equipment | Equipment |
OperationalLimitSet | cim:Equipment.OperationalLimitSet | * OperationalLimitSet |
The operational limit sets associated with this equipment | Equipment |
description | cim:IdentifiedObject.description | 0..1 string |
The description is a free human readable text describing or naming the object | IdentifiedObject |
energyIdentCodeEic | eu:IdentifiedObject.energyIdentCodeEic | 0..1 string |
The attribute is used for an exchange of the EIC code (Energy identification ... | IdentifiedObject |
mRID | cim:IdentifiedObject.mRID | 1 string |
Master resource identifier issued by a model authority | IdentifiedObject |
name | cim:IdentifiedObject.name | 1 string |
The name is any free human readable and possibly non unique text naming the o... | IdentifiedObject |
shortName | eu:IdentifiedObject.shortName | 0..1 string |
The attribute is used for an exchange of a human readable short name with len... | IdentifiedObject |
Identifier and Mapping Information
Schema Source
- from schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
Mappings
Mapping Type | Mapped Value |
---|---|
self | cim:Jumper |
native | this:Jumper |