NonConformLoad
NonConformLoad represents loads that do not follow a daily load change pattern and whose changes are not correlated with the daily load change pattern.
URI: cim:NonConformLoad
Type: Class
classDiagram
class NonConformLoad
click NonConformLoad href "../NonConformLoad"
EnergyConsumer <|-- NonConformLoad
click EnergyConsumer href "../EnergyConsumer"
NonConformLoad : Equipment.aggregate
NonConformLoad : ConductingEquipment.BaseVoltage
NonConformLoad --> BaseVoltage : ConductingEquipment.BaseVoltage
click BaseVoltage href "../BaseVoltage"
NonConformLoad : IdentifiedObject.description
NonConformLoad : IdentifiedObject.energyIdentCodeEic
NonConformLoad : Equipment.EquipmentContainer
NonConformLoad --> EquipmentContainer : Equipment.EquipmentContainer
click EquipmentContainer href "../EquipmentContainer"
NonConformLoad : NonConformLoad.LoadGroup
NonConformLoad --> NonConformLoadGroup : NonConformLoad.LoadGroup
click NonConformLoadGroup href "../NonConformLoadGroup"
NonConformLoad : EnergyConsumer.LoadResponse
NonConformLoad --> LoadResponseCharacteristic : EnergyConsumer.LoadResponse
click LoadResponseCharacteristic href "../LoadResponseCharacteristic"
NonConformLoad : IdentifiedObject.mRID
NonConformLoad : IdentifiedObject.name
NonConformLoad : Equipment.normallyInService
NonConformLoad : Equipment.OperationalLimitSet
NonConformLoad --> OperationalLimitSet : Equipment.OperationalLimitSet
click OperationalLimitSet href "../OperationalLimitSet"
NonConformLoad : EnergyConsumer.pfixed
NonConformLoad --> ActivePower : EnergyConsumer.pfixed
click ActivePower href "../ActivePower"
NonConformLoad : EnergyConsumer.pfixedPct
NonConformLoad --> PerCent : EnergyConsumer.pfixedPct
click PerCent href "../PerCent"
NonConformLoad : EnergyConsumer.qfixed
NonConformLoad --> ReactivePower : EnergyConsumer.qfixed
click ReactivePower href "../ReactivePower"
NonConformLoad : EnergyConsumer.qfixedPct
NonConformLoad --> PerCent : EnergyConsumer.qfixedPct
click PerCent href "../PerCent"
NonConformLoad : IdentifiedObject.shortName
NonConformLoad : ConductingEquipment.Terminals
NonConformLoad --> Terminal : ConductingEquipment.Terminals
click Terminal href "../Terminal"
Inheritance
Attributes
Name | URI | Cardinality and Range | Description | Inheritance |
---|---|---|---|---|
LoadGroup | cim:NonConformLoad.LoadGroup | 1 NonConformLoadGroup |
Group of this ConformLoad | direct |
pfixed | cim:EnergyConsumer.pfixed | 0..1 ActivePower |
Active power of the load that is a fixed quantity and does not vary as load g... | EnergyConsumer |
pfixedPct | cim:EnergyConsumer.pfixedPct | 0..1 PerCent |
Fixed active power as a percentage of load group fixed active power | EnergyConsumer |
qfixed | cim:EnergyConsumer.qfixed | 0..1 ReactivePower |
Reactive power of the load that is a fixed quantity and does not vary as load... | EnergyConsumer |
qfixedPct | cim:EnergyConsumer.qfixedPct | 0..1 PerCent |
Fixed reactive power as a percentage of load group fixed reactive power | EnergyConsumer |
LoadResponse | cim:EnergyConsumer.LoadResponse | 0..1 LoadResponseCharacteristic |
The load response characteristic of this load | EnergyConsumer |
BaseVoltage | cim:ConductingEquipment.BaseVoltage | 0..1 BaseVoltage |
Base voltage of this conducting equipment | ConductingEquipment |
Terminals | cim:ConductingEquipment.Terminals | * Terminal |
Conducting equipment have terminals that may be connected to other conducting... | ConductingEquipment |
aggregate | cim:Equipment.aggregate | 0..1 boolean |
The aggregate flag provides an alternative way of representing an aggregated ... | Equipment |
normallyInService | cim:Equipment.normallyInService | 0..1 boolean |
Specifies the availability of the equipment under normal operating conditions | Equipment |
EquipmentContainer | cim:Equipment.EquipmentContainer | 0..1 EquipmentContainer |
Container of this equipment | Equipment |
OperationalLimitSet | cim:Equipment.OperationalLimitSet | * OperationalLimitSet |
The operational limit sets associated with this equipment | Equipment |
description | cim:IdentifiedObject.description | 0..1 string |
The description is a free human readable text describing or naming the object | IdentifiedObject |
energyIdentCodeEic | eu:IdentifiedObject.energyIdentCodeEic | 0..1 string |
The attribute is used for an exchange of the EIC code (Energy identification ... | IdentifiedObject |
mRID | cim:IdentifiedObject.mRID | 1 string |
Master resource identifier issued by a model authority | IdentifiedObject |
name | cim:IdentifiedObject.name | 1 string |
The name is any free human readable and possibly non unique text naming the o... | IdentifiedObject |
shortName | eu:IdentifiedObject.shortName | 0..1 string |
The attribute is used for an exchange of a human readable short name with len... | IdentifiedObject |
Usages
used by | used in | type | used |
---|---|---|---|
NonConformLoadGroup | EnergyConsumers | range | NonConformLoad |
Identifier and Mapping Information
Schema Source
- from schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
Mappings
Mapping Type | Mapped Value |
---|---|
self | cim:NonConformLoad |
native | this:NonConformLoad |