PhaseTapChangerSymmetrical
Describes a symmetrical phase shifting transformer tap model in which the voltage magnitude of both sides is the same. The difference voltage magnitude is the base in an equal-sided triangle where the sides corresponds to the primary and secondary voltages. The phase angle difference corresponds to the top angle and can be expressed as twice the arctangent of half the total difference voltage.
URI: cim:PhaseTapChangerSymmetrical
Type: Class
classDiagram
class PhaseTapChangerSymmetrical
click PhaseTapChangerSymmetrical href "../PhaseTapChangerSymmetrical"
PhaseTapChangerNonLinear <|-- PhaseTapChangerSymmetrical
click PhaseTapChangerNonLinear href "../PhaseTapChangerNonLinear"
PhaseTapChangerSymmetrical : IdentifiedObject.description
PhaseTapChangerSymmetrical : IdentifiedObject.energyIdentCodeEic
PhaseTapChangerSymmetrical : TapChanger.highStep
PhaseTapChangerSymmetrical : TapChanger.lowStep
PhaseTapChangerSymmetrical : TapChanger.ltcFlag
PhaseTapChangerSymmetrical : IdentifiedObject.mRID
PhaseTapChangerSymmetrical : IdentifiedObject.name
PhaseTapChangerSymmetrical : TapChanger.neutralStep
PhaseTapChangerSymmetrical : TapChanger.neutralU
PhaseTapChangerSymmetrical --> Voltage : TapChanger.neutralU
click Voltage href "../Voltage"
PhaseTapChangerSymmetrical : TapChanger.normalStep
PhaseTapChangerSymmetrical : IdentifiedObject.shortName
PhaseTapChangerSymmetrical : TapChanger.TapChangerControl
PhaseTapChangerSymmetrical --> TapChangerControl : TapChanger.TapChangerControl
click TapChangerControl href "../TapChangerControl"
PhaseTapChangerSymmetrical : TapChanger.TapSchedules
PhaseTapChangerSymmetrical --> TapSchedule : TapChanger.TapSchedules
click TapSchedule href "../TapSchedule"
PhaseTapChangerSymmetrical : PhaseTapChanger.TransformerEnd
PhaseTapChangerSymmetrical --> TransformerEnd : PhaseTapChanger.TransformerEnd
click TransformerEnd href "../TransformerEnd"
PhaseTapChangerSymmetrical : PhaseTapChangerNonLinear.voltageStepIncrement
PhaseTapChangerSymmetrical --> PerCent : PhaseTapChangerNonLinear.voltageStepIncrement
click PerCent href "../PerCent"
PhaseTapChangerSymmetrical : PhaseTapChangerNonLinear.xMax
PhaseTapChangerSymmetrical --> Reactance : PhaseTapChangerNonLinear.xMax
click Reactance href "../Reactance"
PhaseTapChangerSymmetrical : PhaseTapChangerNonLinear.xMin
PhaseTapChangerSymmetrical --> Reactance : PhaseTapChangerNonLinear.xMin
click Reactance href "../Reactance"
Inheritance
- IdentifiedObject
- PowerSystemResource
- TapChanger
- PhaseTapChanger
- PhaseTapChangerNonLinear
- PhaseTapChangerSymmetrical
- PhaseTapChangerNonLinear
- PhaseTapChanger
- TapChanger
- PowerSystemResource
Attributes
Name | URI | Cardinality and Range | Description | Inheritance |
---|---|---|---|---|
voltageStepIncrement | cim:PhaseTapChangerNonLinear.voltageStepIncrement | 1 PerCent |
The voltage step increment on the out of phase winding (the PowerTransformerE... | PhaseTapChangerNonLinear |
xMax | cim:PhaseTapChangerNonLinear.xMax | 1 Reactance |
The reactance depends on the tap position according to a "u" shaped curve | PhaseTapChangerNonLinear |
xMin | cim:PhaseTapChangerNonLinear.xMin | 1 Reactance |
The reactance depend on the tap position according to a "u" shaped curve | PhaseTapChangerNonLinear |
TransformerEnd | cim:PhaseTapChanger.TransformerEnd | 1 TransformerEnd |
Transformer end to which this phase tap changer belongs | PhaseTapChanger |
TapSchedules | cim:TapChanger.TapSchedules | * TapSchedule |
A TapChanger can have TapSchedules | TapChanger |
highStep | cim:TapChanger.highStep | 1 integer |
Highest possible tap step position, advance from neutral | TapChanger |
lowStep | cim:TapChanger.lowStep | 1 integer |
Lowest possible tap step position, retard from neutral | TapChanger |
ltcFlag | cim:TapChanger.ltcFlag | 1 boolean |
Specifies whether or not a TapChanger has load tap changing capabilities | TapChanger |
neutralStep | cim:TapChanger.neutralStep | 1 integer |
The neutral tap step position for this winding | TapChanger |
neutralU | cim:TapChanger.neutralU | 1 Voltage |
Voltage at which the winding operates at the neutral tap setting | TapChanger |
normalStep | cim:TapChanger.normalStep | 1 integer |
The tap step position used in "normal" network operation for this winding | TapChanger |
TapChangerControl | cim:TapChanger.TapChangerControl | 0..1 TapChangerControl |
The regulating control scheme in which this tap changer participates | TapChanger |
description | cim:IdentifiedObject.description | 0..1 string |
The description is a free human readable text describing or naming the object | IdentifiedObject |
energyIdentCodeEic | eu:IdentifiedObject.energyIdentCodeEic | 0..1 string |
The attribute is used for an exchange of the EIC code (Energy identification ... | IdentifiedObject |
mRID | cim:IdentifiedObject.mRID | 1 string |
Master resource identifier issued by a model authority | IdentifiedObject |
name | cim:IdentifiedObject.name | 1 string |
The name is any free human readable and possibly non unique text naming the o... | IdentifiedObject |
shortName | eu:IdentifiedObject.shortName | 0..1 string |
The attribute is used for an exchange of a human readable short name with len... | IdentifiedObject |
Identifier and Mapping Information
Schema Source
- from schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
Mappings
Mapping Type | Mapped Value |
---|---|
self | cim:PhaseTapChangerSymmetrical |
native | this:PhaseTapChangerSymmetrical |