PotentialTransformer
Instrument transformer (also known as Voltage Transformer) used to measure electrical qualities of the circuit that is being protected and/or monitored. Typically used as voltage transducer for the purpose of metering, protection, or sometimes auxiliary substation supply. A typical secondary voltage rating would be 120V.
URI: cim:PotentialTransformer
Type: Class
classDiagram
class PotentialTransformer
click PotentialTransformer href "../PotentialTransformer"
Sensor <|-- PotentialTransformer
click Sensor href "../Sensor"
PotentialTransformer : Equipment.aggregate
PotentialTransformer : IdentifiedObject.description
PotentialTransformer : IdentifiedObject.energyIdentCodeEic
PotentialTransformer : Equipment.EquipmentContainer
PotentialTransformer --> EquipmentContainer : Equipment.EquipmentContainer
click EquipmentContainer href "../EquipmentContainer"
PotentialTransformer : IdentifiedObject.mRID
PotentialTransformer : IdentifiedObject.name
PotentialTransformer : Equipment.normallyInService
PotentialTransformer : Equipment.OperationalLimitSet
PotentialTransformer --> OperationalLimitSet : Equipment.OperationalLimitSet
click OperationalLimitSet href "../OperationalLimitSet"
PotentialTransformer : IdentifiedObject.shortName
PotentialTransformer : AuxiliaryEquipment.Terminal
PotentialTransformer --> Terminal : AuxiliaryEquipment.Terminal
click Terminal href "../Terminal"
Inheritance
- IdentifiedObject
- PowerSystemResource
- Equipment
- AuxiliaryEquipment
- Sensor
- PotentialTransformer
- Sensor
- AuxiliaryEquipment
- Equipment
- PowerSystemResource
Attributes
Name | URI | Cardinality and Range | Description | Inheritance |
---|---|---|---|---|
Terminal | cim:AuxiliaryEquipment.Terminal | 1 Terminal |
The Terminal at the equipment where the AuxiliaryEquipment is attached | AuxiliaryEquipment |
aggregate | cim:Equipment.aggregate | 0..1 boolean |
The aggregate flag provides an alternative way of representing an aggregated ... | Equipment |
normallyInService | cim:Equipment.normallyInService | 0..1 boolean |
Specifies the availability of the equipment under normal operating conditions | Equipment |
EquipmentContainer | cim:Equipment.EquipmentContainer | 0..1 EquipmentContainer |
Container of this equipment | Equipment |
OperationalLimitSet | cim:Equipment.OperationalLimitSet | * OperationalLimitSet |
The operational limit sets associated with this equipment | Equipment |
description | cim:IdentifiedObject.description | 0..1 string |
The description is a free human readable text describing or naming the object | IdentifiedObject |
energyIdentCodeEic | eu:IdentifiedObject.energyIdentCodeEic | 0..1 string |
The attribute is used for an exchange of the EIC code (Energy identification ... | IdentifiedObject |
mRID | cim:IdentifiedObject.mRID | 1 string |
Master resource identifier issued by a model authority | IdentifiedObject |
name | cim:IdentifiedObject.name | 1 string |
The name is any free human readable and possibly non unique text naming the o... | IdentifiedObject |
shortName | eu:IdentifiedObject.shortName | 0..1 string |
The attribute is used for an exchange of a human readable short name with len... | IdentifiedObject |
Identifier and Mapping Information
Schema Source
- from schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
Mappings
Mapping Type | Mapped Value |
---|---|
self | cim:PotentialTransformer |
native | this:PotentialTransformer |