Skip to content

PowerElectronicsConnection

A connection to the AC network for energy production or consumption that uses power electronics rather than rotating machines.

URI: cim:PowerElectronicsConnection
Type: Class

 classDiagram
    class PowerElectronicsConnection
    click PowerElectronicsConnection href "../PowerElectronicsConnection"
      RegulatingCondEq <|-- PowerElectronicsConnection
        click RegulatingCondEq href "../RegulatingCondEq"

      PowerElectronicsConnection : Equipment.aggregate

      PowerElectronicsConnection : ConductingEquipment.BaseVoltage

          PowerElectronicsConnection --> BaseVoltage : ConductingEquipment.BaseVoltage
          click BaseVoltage href "../BaseVoltage"

      PowerElectronicsConnection : IdentifiedObject.description

      PowerElectronicsConnection : IdentifiedObject.energyIdentCodeEic

      PowerElectronicsConnection : Equipment.EquipmentContainer

          PowerElectronicsConnection --> EquipmentContainer : Equipment.EquipmentContainer
          click EquipmentContainer href "../EquipmentContainer"

      PowerElectronicsConnection : PowerElectronicsConnection.maxQ

          PowerElectronicsConnection --> ReactivePower : PowerElectronicsConnection.maxQ
          click ReactivePower href "../ReactivePower"

      PowerElectronicsConnection : PowerElectronicsConnection.minQ

          PowerElectronicsConnection --> ReactivePower : PowerElectronicsConnection.minQ
          click ReactivePower href "../ReactivePower"

      PowerElectronicsConnection : IdentifiedObject.mRID

      PowerElectronicsConnection : IdentifiedObject.name

      PowerElectronicsConnection : Equipment.normallyInService

      PowerElectronicsConnection : Equipment.OperationalLimitSet

          PowerElectronicsConnection --> OperationalLimitSet : Equipment.OperationalLimitSet
          click OperationalLimitSet href "../OperationalLimitSet"

      PowerElectronicsConnection : PowerElectronicsConnection.PowerElectronicsUnit

          PowerElectronicsConnection --> PowerElectronicsUnit : PowerElectronicsConnection.PowerElectronicsUnit
          click PowerElectronicsUnit href "../PowerElectronicsUnit"

      PowerElectronicsConnection : PowerElectronicsConnection.ratedS

          PowerElectronicsConnection --> ApparentPower : PowerElectronicsConnection.ratedS
          click ApparentPower href "../ApparentPower"

      PowerElectronicsConnection : PowerElectronicsConnection.ratedU

          PowerElectronicsConnection --> Voltage : PowerElectronicsConnection.ratedU
          click Voltage href "../Voltage"

      PowerElectronicsConnection : RegulatingCondEq.RegulatingControl

          PowerElectronicsConnection --> RegulatingControl : RegulatingCondEq.RegulatingControl
          click RegulatingControl href "../RegulatingControl"

      PowerElectronicsConnection : IdentifiedObject.shortName

      PowerElectronicsConnection : ConductingEquipment.Terminals

          PowerElectronicsConnection --> Terminal : ConductingEquipment.Terminals
          click Terminal href "../Terminal"

Inheritance

Attributes

Name URI Cardinality and Range Description Inheritance
maxQ cim:PowerElectronicsConnection.maxQ 0..1
ReactivePower
Maximum reactive power limit direct
minQ cim:PowerElectronicsConnection.minQ 0..1
ReactivePower
Minimum reactive power limit for the unit direct
ratedS cim:PowerElectronicsConnection.ratedS 0..1
ApparentPower
Nameplate apparent power rating for the unit direct
ratedU cim:PowerElectronicsConnection.ratedU 0..1
Voltage
Rated voltage (nameplate data, Ur in IEC 60909-0) direct
PowerElectronicsUnit cim:PowerElectronicsConnection.PowerElectronicsUnit 0..1
PowerElectronicsUnit
An AC network connection may have several power electronics units connecting ... direct
RegulatingControl cim:RegulatingCondEq.RegulatingControl 0..1
RegulatingControl
The regulating control scheme in which this equipment participates RegulatingCondEq
BaseVoltage cim:ConductingEquipment.BaseVoltage 0..1
BaseVoltage
Base voltage of this conducting equipment ConductingEquipment
Terminals cim:ConductingEquipment.Terminals *
Terminal
Conducting equipment have terminals that may be connected to other conducting... ConductingEquipment
aggregate cim:Equipment.aggregate 0..1
boolean
The aggregate flag provides an alternative way of representing an aggregated ... Equipment
normallyInService cim:Equipment.normallyInService 0..1
boolean
Specifies the availability of the equipment under normal operating conditions Equipment
EquipmentContainer cim:Equipment.EquipmentContainer 0..1
EquipmentContainer
Container of this equipment Equipment
OperationalLimitSet cim:Equipment.OperationalLimitSet *
OperationalLimitSet
The operational limit sets associated with this equipment Equipment
description cim:IdentifiedObject.description 0..1
string
The description is a free human readable text describing or naming the object IdentifiedObject
energyIdentCodeEic eu:IdentifiedObject.energyIdentCodeEic 0..1
string
The attribute is used for an exchange of the EIC code (Energy identification ... IdentifiedObject
mRID cim:IdentifiedObject.mRID 1
string
Master resource identifier issued by a model authority IdentifiedObject
name cim:IdentifiedObject.name 1
string
The name is any free human readable and possibly non unique text naming the o... IdentifiedObject
shortName eu:IdentifiedObject.shortName 0..1
string
The attribute is used for an exchange of a human readable short name with len... IdentifiedObject

Usages

used by used in type used
BatteryUnit PowerElectronicsConnection range PowerElectronicsConnection
PhotoVoltaicUnit PowerElectronicsConnection range PowerElectronicsConnection
PowerElectronicsUnit PowerElectronicsConnection range PowerElectronicsConnection
PowerElectronicsWindUnit PowerElectronicsConnection range PowerElectronicsConnection

Identifier and Mapping Information

Schema Source

  • from schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile

Mappings

Mapping Type Mapped Value
self cim:PowerElectronicsConnection
native this:PowerElectronicsConnection