Dynamics Vocabulary
This vocabulary is describing the dynamics profile from IEC 61970-600-2.
URI: http://iec.ch/TC57/ns/CIM/Dynamics-EU#Package_DynamicsProfile
Name: DynamicsProfile
Classes
| Class | Description |
|---|---|
| ActivePower | Product of RMS value of the voltage and the RMS value of the in-phase compone... |
| AngleDegrees | Measurement of angle in degrees |
| ApparentPower | Product of the RMS value of the voltage and the RMS value of the current |
| Area | Area |
| Frequency | Cycles per second |
| IdentifiedObject | This is a root class to provide common identification for all classes needing... |
| ACDCTerminal | An electrical connection point (AC or DC) to a piece of conducting equipment |
| Terminal | An AC electrical connection point to a piece of conducting equipment |
| DynamicsFunctionBlock | Abstract parent class for all Dynamics function blocks |
| CrossCompoundTurbineGovernorDynamics | Turbine-governor cross-compound function block whose behaviour is described b... |
| GovSteamCC | Cross compound turbine governor |
| DiscontinuousExcitationControlDynamics | Discontinuous excitation control function block whose behaviour is described ... |
| DiscExcContIEEEDEC1A | IEEE type DEC1A discontinuous excitation control model that boosts generator ... |
| DiscExcContIEEEDEC2A | IEEE type DEC2A model for discontinuous excitation control |
| DiscExcContIEEEDEC3A | IEEE type DEC3A model |
| DiscontinuousExcitationControlUserDefined | Discontinuous excitation control function block whose dynamic behaviour is de... |
| ExcitationSystemDynamics | Excitation system function block whose behaviour is described by reference to... |
| ExcAC1A | Modified IEEE AC1A alternator-supplied rectifier excitation system with diffe... |
| ExcAC2A | Modified IEEE AC2A alternator-supplied rectifier excitation system with diffe... |
| ExcAC3A | Modified IEEE AC3A alternator-supplied rectifier excitation system with diffe... |
| ExcAC4A | Modified IEEE AC4A alternator-supplied rectifier excitation system with diffe... |
| ExcAC5A | Modified IEEE AC5A alternator-supplied rectifier excitation system with diffe... |
| ExcAC6A | Modified IEEE AC6A alternator-supplied rectifier excitation system with speed... |
| ExcAC8B | Modified IEEE AC8B alternator-supplied rectifier excitation system with speed... |
| ExcANS | Italian excitation system |
| ExcAVR1 | Italian excitation system corresponding to IEEE (1968) type 1 model |
| ExcAVR2 | Italian excitation system corresponding to IEEE (1968) type 2 model |
| ExcAVR3 | Italian excitation system |
| ExcAVR4 | Italian excitation system |
| ExcAVR5 | Manual excitation control with field circuit resistance |
| ExcAVR7 | IVO excitation system |
| ExcBBC | Transformer fed static excitation system (static with ABB regulator) |
| ExcCZ | Czech proportion/integral exciter |
| ExcDC1A | Modified IEEE DC1A direct current commutator exciter with speed input and wit... |
| ExcDC2A | Modified IEEE DC2A direct current commutator exciter with speed input, one mo... |
| ExcDC3A | Modified IEEE DC3A direct current commutator exciter with speed input, and de... |
| ExcDC3A1 | Modified old IEEE type 3 excitation system |
| ExcELIN1 | Static PI transformer fed excitation system ELIN (VATECH) - simplified model |
| ExcELIN2 | Detailed excitation system ELIN (VATECH) |
| ExcHU | Hungarian excitation system, with built-in voltage transducer |
| ExcIEEEAC1A | IEEE 421 |
| ExcIEEEAC2A | IEEE 421 |
| ExcIEEEAC3A | IEEE 421 |
| ExcIEEEAC4A | IEEE 421 |
| ExcIEEEAC5A | IEEE 421 |
| ExcIEEEAC6A | IEEE 421 |
| ExcIEEEAC7B | IEEE 421 |
| ExcIEEEAC8B | IEEE 421 |
| ExcIEEEDC1A | IEEE 421 |
| ExcIEEEDC2A | IEEE 421 |
| ExcIEEEDC3A | IEEE 421 |
| ExcIEEEDC4B | IEEE 421 |
| ExcIEEEST1A | IEEE 421 |
| ExcIEEEST2A | IEEE 421 |
| ExcIEEEST3A | IEEE 421 |
| ExcIEEEST4B | IEEE 421 |
| ExcIEEEST5B | IEEE 421 |
| ExcIEEEST6B | IEEE 421 |
| ExcIEEEST7B | IEEE 421 |
| ExcitationSystemUserDefined | Excitation system function block whose dynamic behaviour is described by <fon... |
| ExcNI | Bus or solid fed SCR (silicon-controlled rectifier) bridge excitation system ... |
| ExcOEX3T | Modified IEEE type ST1 excitation system with semi-continuous and acting term... |
| ExcPIC | Proportional/integral regulator excitation system |
| ExcREXS | General purpose rotating excitation system |
| ExcRQB | Excitation system type RQB (four-loop regulator, r?gulateur quatre boucles, d... |
| ExcSCRX | Simple excitation system with generic characteristics typical of many excitat... |
| ExcSEXS | Simplified excitation system |
| ExcSK | Slovakian excitation system |
| ExcST1A | Modification of an old IEEE ST1A static excitation system without overexcitat... |
| ExcST2A | Modified IEEE ST2A static excitation system with another lead-lag block added... |
| ExcST3A | Modified IEEE ST3A static excitation system with added speed multiplier |
| ExcST4B | Modified IEEE ST4B static excitation system with maximum inner loop feedback ... |
| ExcST6B | Modified IEEE ST6B static excitation system with PID controller and optional ... |
| ExcST7B | Modified IEEE ST7B static excitation system without stator current limiter (S... |
| HVDCDynamics | HVDC whose behaviour is described by reference to a standard model <font colo... |
| CSCDynamics | CSC function block whose behaviour is described by reference to a standard mo... |
| CSCUserDefined | Current source converter (CSC) function block whose dynamic behaviour is desc... |
| VSCDynamics | VSC function block whose behaviour is described by reference to a standard mo... |
| VSCUserDefined | Voltage source converter (VSC) function block whose dynamic behaviour is desc... |
| MechanicalLoadDynamics | Mechanical load function block whose behaviour is described by reference to a... |
| MechanicalLoadUserDefined | Mechanical load function block whose dynamic behaviour is described by <font ... |
| MechLoad1 | Mechanical load model type 1 |
| OverexcitationLimiterDynamics | Overexcitation limiter function block whose behaviour is described by referen... |
| OverexcitationLimiterUserDefined | Overexcitation limiter system function block whose dynamic behaviour is descr... |
| OverexcLim2 | Different from LimIEEEOEL, LimOEL2 has a fixed pickup threshold and reduces t... |
| OverexcLimIEEE | The over excitation limiter model is intended to represent the significant fe... |
| OverexcLimX1 | Field voltage over excitation limiter |
| OverexcLimX2 | Field voltage or current overexcitation limiter designed to protect the gener... |
| PFVArControllerType1Dynamics | Power factor or VAr controller type 1 function block whose behaviour is descr... |
| PFVArControllerType1UserDefined | Power factor or VAr controller type 1 function block whose dynamic behaviour ... |
| PFVArType1IEEEPFController | IEEE PF controller type 1 which operates by moving the voltage reference dire... |
| PFVArType1IEEEVArController | IEEE VAR controller type 1 which operates by moving the voltage reference dir... |
| PFVArControllerType2Dynamics | Power factor or VAr controller type 2 function block whose behaviour is descr... |
| PFVArControllerType2UserDefined | Power factor or VAr controller type 2 function block whose dynamic behaviour ... |
| PFVArType2Common1 | Power factor / reactive power regulator |
| PFVArType2IEEEPFController | IEEE PF controller type 2 which is a summing point type controller making up ... |
| PFVArType2IEEEVArController | IEEE VAR controller type 2 which is a summing point type controller |
| PowerSystemStabilizerDynamics | Power system stabilizer function block whose behaviour is described by refere... |
| PowerSystemStabilizerUserDefined | Power system stabilizer function block whose dyn... |
| Pss1 | Italian PSS with three inputs (speed, frequency, power) |
| Pss1A | Single input power system stabilizer |
| Pss2B | Modified IEEE PSS2B |
| Pss2ST | PTI microprocessor-based stabilizer type 1 |
| Pss5 | Detailed Italian PSS |
| PssELIN2 | Power system stabilizer typically associated with ExcELIN2 (though PssIEEE2B ... |
| PssIEEE1A | IEEE 421 |
| PssIEEE2B | IEEE 421 |
| PssIEEE3B | IEEE 421 |
| PssIEEE4B | IEEE 421 |
| PssPTIST1 | PTI microprocessor-based stabilizer type 1 |
| PssPTIST3 | PTI microprocessor-based stabilizer type 3 |
| PssRQB | Power system stabilizer type RQB |
| PssSB4 | Power sensitive stabilizer model |
| PssSH | SiemensTM “H infinity” power system stabilizer with generator elec... |
| PssSK | Slovakian PSS with three inputs |
| PssSTAB2A | Power system stabilizer part of an ABB excitation system |
| PssWECC | Dual input power system stabilizer, based on IEEE type 2, with modified outpu... |
| RotatingMachineDynamics | Abstract parent class for all synchronous and asynchronous machine standard m... |
| AsynchronousMachineDynamics | Asynchronous machine whose behaviour is described by reference to a standard ... |
| AsynchronousMachineEquivalentCircuit | The electrical equations of all variations of the asynchronous model are base... |
| AsynchronousMachineTimeConstantReactance | Parameter details: |
| AsynchronousMachineUserDefined | Asynchronous machine whose dynamic behaviour is described by a user-defined m... |
| SynchronousMachineDynamics | Synchronous machine whose behaviour is described by reference to a standard m... |
| SynchronousMachineDetailed | All synchronous machine detailed types use a subset of the same data paramete... |
| SynchronousMachineEquivalentCircuit | The electrical equations for all variations of the synchronous models are bas... |
| SynchronousMachineTimeConstantReactance | Synchronous machine detailed modelling types are defined by the combination o... |
| SynchronousMachineSimplified | The simplified model represents a synchronous generator as a constant interna... |
| SynchronousMachineUserDefined | Synchronous machine whose dynamic behaviour is described by a user-defined mo... |
| StaticVarCompensatorDynamics | Static var compensator whose behaviour is described by reference to a standar... |
| SVCUserDefined | Static var compensator (SVC) function block whose dynamic behaviour is descri... |
| TurbineGovernorDynamics | Turbine-governor function block whose behaviour is described by reference to ... |
| GovCT1 | General model for any prime mover with a PID governor, used primarily for com... |
| GovCT2 | General governor with frequency-dependent fuel flow limit |
| GovGAST | Single shaft gas turbine |
| GovGAST1 | Modified single shaft gas turbine |
| GovGAST2 | Gas turbine |
| GovGAST3 | Generic turbogas with acceleration and temperature controller |
| GovGAST4 | Generic turbogas |
| GovGASTWD | Woodward™ gas turbine governor |
| GovHydro1 | Basic hydro turbine governor |
| GovHydro2 | IEEE hydro turbine governor with straightforward penstock configuration and h... |
| GovHydro3 | Modified IEEE hydro governor-turbine |
| GovHydro4 | Hydro turbine and governor |
| GovHydroDD | Double derivative hydro governor and turbine |
| GovHydroFrancis | Detailed hydro unit - Francis model |
| GovHydroIEEE0 | IEEE simplified hydro governor-turbine model |
| GovHydroIEEE2 | IEEE hydro turbine governor model represents plants with straightforward pens... |
| GovHydroPelton | Detailed hydro unit - Pelton model |
| GovHydroPID | PID governor and turbine |
| GovHydroPID2 | Hydro turbine and governor |
| GovHydroR | Fourth order lead-lag governor and hydro turbine |
| GovHydroWEH | WoodwardTM electric hydro governor |
| GovHydroWPID | WoodwardTM PID hydro governor |
| GovSteam0 | A simplified steam turbine governor |
| GovSteam1 | Steam turbine governor, based on the GovSteamIEEE1 (with optional deadband an... |
| GovSteam2 | Simplified governor |
| GovSteamBB | European governor model |
| GovSteamEU | Simplified boiler and steam turbine with PID governor |
| GovSteamFV2 | Steam turbine governor with reheat time constants and modelling of the effect... |
| GovSteamFV3 | Simplified GovSteamIEEE1 steam turbine governor with Prmax limit and fast val... |
| GovSteamFV4 | Detailed electro-hydraulic governor for steam unit |
| GovSteamIEEE1 | IEEE steam turbine governor model |
| GovSteamSGO | Simplified steam turbine governor |
| TurbineGovernorUserDefined | Turbine-governor function block whose dynamic behaviour is described by <font... |
| TurbineLoadControllerDynamics | Turbine load controller function block whose behaviour is described by refere... |
| TurbineLoadControllerUserDefined | Turbine load controller function block whose dynamic behaviour is described b... |
| TurbLCFB1 | Turbine load controller model developed by WECC |
| UnderexcitationLimiterDynamics | Underexcitation limiter function block whose behaviour is described by refere... |
| UnderexcitationLimiterUserDefined | Underexcitation limiter function block whose dynamic behaviour is described b... |
| UnderexcLim2Simplified | Simplified type UEL2 underexcitation limiter |
| UnderexcLimIEEE1 | Type UEL1 model which has a circular limit boundary when plotted in terms of ... |
| UnderexcLimIEEE2 | Type UEL2 underexcitation limiter which has either a straight-line or multi-s... |
| UnderexcLimX1 | Allis-Chalmers minimum excitation limiter |
| UnderexcLimX2 | Westinghouse minimum excitation limiter |
| VoltageAdjusterDynamics | Voltage adjuster function block whose behaviour is described by reference to ... |
| VAdjIEEE | IEEE voltage adjuster which is used to represent the voltage adjuster in eith... |
| VoltageAdjusterUserDefined | Voltage adjuster function block whose dynamic be... |
| VoltageCompensatorDynamics | Voltage compensator function block whose behaviour is described by reference ... |
| VCompIEEEType1 | Terminal voltage transducer and load compensator as def... |
| VCompIEEEType2 | Terminal voltage transducer and load compensator as def... |
| VoltageCompensatorUserDefined | Voltage compensator function block whose dynamic behaviour is described by <f... |
| WindPlantDynamics | Parent class supporting relationships to wind turbines type 3 and type 4 and ... |
| WindPlantIEC | Simplified IEC type plant level model |
| WindPlantUserDefined | Wind plant function block whose dynamic behaviour is described by <font color... |
| WindTurbineType1or2Dynamics | Parent class supporting relationships to wind turbines type 1 and type 2 and ... |
| WindTurbineType1or2IEC | Parent class supporting relationships to IEC wind turbines type 1 and type 2 ... |
| WindGenTurbineType1aIEC | Wind turbine IEC type 1A |
| WindGenTurbineType1bIEC | Wind turbine IEC type 1B |
| WindGenTurbineType2IEC | Wind turbine IEC type 2 |
| WindType1or2UserDefined | Wind type 1 or type 2 function block whose dynamic behaviour is described by ... |
| WindTurbineType3or4Dynamics | Parent class supporting relationships to wind turbines type 3 and type 4 and ... |
| WindTurbineType3or4IEC | Parent class supporting relationships to IEC wind turbines type 3 and type 4 ... |
| WindTurbineType3IEC | Parent class supporting relationships to IEC wind turbines type 3 including t... |
| WindTurbineType4IEC | Parent class supporting relationships to IEC wind turbines type 4 including t... |
| WindTurbineType4aIEC | Wind turbine IEC type 4A |
| WindTurbineType4bIEC | Wind turbine IEC type 4B |
| WindType3or4UserDefined | Wind type 3 or type 4 function block whose dynamic behaviour is described by ... |
| GenICompensationForGenJ | Resistive and reactive components of compensation for generator associated wi... |
| LoadDynamics | Load whose behaviour is described by reference to a standard model <font colo... |
| LoadAggregate | Aggregate loads are used to represent all or part of the real and reactive lo... |
| LoadComposite | Combined static load and induction motor load effects |
| LoadGenericNonLinear | Generic non-linear dynamic (GNLD) load |
| LoadUserDefined | Load whose dynamic behaviour is described by a user-defined model |
| LoadMotor | Aggregate induction motor load |
| LoadStatic | General static load |
| PowerSystemResource | A power system resource (PSR) can be an item of equipment such as a switch, a... |
| Equipment | The parts of a power system that are physical devices, electronic or mechanic... |
| ConductingEquipment | The parts of the AC power system that are designed to carry current or that a... |
| ACDCConverter | A unit with valves for three phases, together with unit control equipment, es... |
| CsConverter | DC side of the current source converter (CSC) |
| VsConverter | DC side of the voltage source converter (VSC) |
| EnergyConnection | A connection of energy generation or consumption on the power system model |
| EnergyConsumer | Generic user of energy - a point of consumption on the power system model |
| RegulatingCondEq | A type of conducting equipment that can regulate a quantity (i |
| PowerElectronicsConnection | A connection to the AC network for energy production or consumption that uses... |
| RotatingMachine | A rotating machine which may be used as a generator or motor |
| AsynchronousMachine | A rotating machine whose shaft rotates asynchronously with the electrical fie... |
| SynchronousMachine | An electromechanical device that operates with shaft rotating synchronously w... |
| StaticVarCompensator | A facility for providing variable and controllable shunt reactive power |
| RemoteInputSignal | Supports connection to a terminal associated with a remote bus from which an ... |
| WindAeroConstIEC | Constant aerodynamic torque model which assumes that the aerodynamic torque i... |
| WindAeroOneDimIEC | One-dimensional aerodynamic model |
| WindAeroTwoDimIEC | Two-dimensional aerodynamic model |
| WindContCurrLimIEC | Current limitation model |
| WindContPitchAngleIEC | Pitch angle control model |
| WindContPType3IEC | P control model type 3 |
| WindContPType4aIEC | P control model type 4A |
| WindContPType4bIEC | P control model type 4B |
| WindContQIEC | Q control model |
| WindContQLimIEC | Constant Q limitation model |
| WindContQPQULimIEC | QP and QU limitation model |
| WindContRotorRIEC | Rotor resistance control model |
| WindDynamicsLookupTable | Look up table for the purpose of wind standard models |
| WindGenType3IEC | Parent class supporting relationships to IEC wind turbines type 3 generator m... |
| WindGenType3aIEC | IEC type 3A generator set model |
| WindGenType3bIEC | IEC type 3B generator set model |
| WindGenType4IEC | IEC type 4 generator set model |
| WindMechIEC | Two mass model |
| WindPitchContPowerIEC | Pitch control power model |
| WindPlantFreqPcontrolIEC | Frequency and active power controller model |
| WindPlantReactiveControlIEC | Simplified plant voltage and reactive power control model for use with type 3... |
| WindProtectionIEC | The grid protection model includes protection against over- and under-voltage... |
| WindRefFrameRotIEC | Reference frame rotation model |
| Length | Unit of length |
| ProprietaryParameterDynamics | Supports definition of one or more parameters of several different datatypes ... |
| PU | Per Unit - a positive or negative value referred to a defined base |
| Seconds | Time, in seconds |
| Temperature | Value of temperature in degrees Celsius |
| VolumeFlowRate | Volume per time |