Dynamics Vocabulary
This vocabulary is describing the dynamics profile from IEC 61970-600-2.
URI: http://iec.ch/TC57/ns/CIM/Dynamics-EU#Package_DynamicsProfile
Name: DynamicsProfile
Classes
Class | Description |
---|---|
ActivePower | Product of RMS value of the voltage and the RMS value of the in-phase compone... |
AngleDegrees | Measurement of angle in degrees |
ApparentPower | Product of the RMS value of the voltage and the RMS value of the current |
Area | Area |
Frequency | Cycles per second |
IdentifiedObject | This is a root class to provide common identification for all classes needing... |
ACDCTerminal | An electrical connection point (AC or DC) to a piece of conducting equipment |
Terminal | An AC electrical connection point to a piece of conducting equipment |
DynamicsFunctionBlock | Abstract parent class for all Dynamics function blocks |
CrossCompoundTurbineGovernorDynamics | Turbine-governor cross-compound function block whose behaviour is described b... |
GovSteamCC | Cross compound turbine governor |
DiscontinuousExcitationControlDynamics | Discontinuous excitation control function block whose behaviour is described ... |
DiscExcContIEEEDEC1A | IEEE type DEC1A discontinuous excitation control model that boosts generator ... |
DiscExcContIEEEDEC2A | IEEE type DEC2A model for discontinuous excitation control |
DiscExcContIEEEDEC3A | IEEE type DEC3A model |
DiscontinuousExcitationControlUserDefined | Discontinuous excitation control function block whose dynamic behaviour is de... |
ExcitationSystemDynamics | Excitation system function block whose behaviour is described by reference to... |
ExcAC1A | Modified IEEE AC1A alternator-supplied rectifier excitation system with diffe... |
ExcAC2A | Modified IEEE AC2A alternator-supplied rectifier excitation system with diffe... |
ExcAC3A | Modified IEEE AC3A alternator-supplied rectifier excitation system with diffe... |
ExcAC4A | Modified IEEE AC4A alternator-supplied rectifier excitation system with diffe... |
ExcAC5A | Modified IEEE AC5A alternator-supplied rectifier excitation system with diffe... |
ExcAC6A | Modified IEEE AC6A alternator-supplied rectifier excitation system with speed... |
ExcAC8B | Modified IEEE AC8B alternator-supplied rectifier excitation system with speed... |
ExcANS | Italian excitation system |
ExcAVR1 | Italian excitation system corresponding to IEEE (1968) type 1 model |
ExcAVR2 | Italian excitation system corresponding to IEEE (1968) type 2 model |
ExcAVR3 | Italian excitation system |
ExcAVR4 | Italian excitation system |
ExcAVR5 | Manual excitation control with field circuit resistance |
ExcAVR7 | IVO excitation system |
ExcBBC | Transformer fed static excitation system (static with ABB regulator) |
ExcCZ | Czech proportion/integral exciter |
ExcDC1A | Modified IEEE DC1A direct current commutator exciter with speed input and wit... |
ExcDC2A | Modified IEEE DC2A direct current commutator exciter with speed input, one mo... |
ExcDC3A | Modified IEEE DC3A direct current commutator exciter with speed input, and de... |
ExcDC3A1 | Modified old IEEE type 3 excitation system |
ExcELIN1 | Static PI transformer fed excitation system ELIN (VATECH) - simplified model |
ExcELIN2 | Detailed excitation system ELIN (VATECH) |
ExcHU | Hungarian excitation system, with built-in voltage transducer |
ExcIEEEAC1A | IEEE 421 |
ExcIEEEAC2A | IEEE 421 |
ExcIEEEAC3A | IEEE 421 |
ExcIEEEAC4A | IEEE 421 |
ExcIEEEAC5A | IEEE 421 |
ExcIEEEAC6A | IEEE 421 |
ExcIEEEAC7B | IEEE 421 |
ExcIEEEAC8B | IEEE 421 |
ExcIEEEDC1A | IEEE 421 |
ExcIEEEDC2A | IEEE 421 |
ExcIEEEDC3A | IEEE 421 |
ExcIEEEDC4B | IEEE 421 |
ExcIEEEST1A | IEEE 421 |
ExcIEEEST2A | IEEE 421 |
ExcIEEEST3A | IEEE 421 |
ExcIEEEST4B | IEEE 421 |
ExcIEEEST5B | IEEE 421 |
ExcIEEEST6B | IEEE 421 |
ExcIEEEST7B | IEEE 421 |
ExcitationSystemUserDefined | Excitation system function block whose dynamic behaviour is described by <fon... |
ExcNI | Bus or solid fed SCR (silicon-controlled rectifier) bridge excitation system ... |
ExcOEX3T | Modified IEEE type ST1 excitation system with semi-continuous and acting term... |
ExcPIC | Proportional/integral regulator excitation system |
ExcREXS | General purpose rotating excitation system |
ExcRQB | Excitation system type RQB (four-loop regulator, r?gulateur quatre boucles, d... |
ExcSCRX | Simple excitation system with generic characteristics typical of many excitat... |
ExcSEXS | Simplified excitation system |
ExcSK | Slovakian excitation system |
ExcST1A | Modification of an old IEEE ST1A static excitation system without overexcitat... |
ExcST2A | Modified IEEE ST2A static excitation system with another lead-lag block added... |
ExcST3A | Modified IEEE ST3A static excitation system with added speed multiplier |
ExcST4B | Modified IEEE ST4B static excitation system with maximum inner loop feedback ... |
ExcST6B | Modified IEEE ST6B static excitation system with PID controller and optional ... |
ExcST7B | Modified IEEE ST7B static excitation system without stator current limiter (S... |
HVDCDynamics | HVDC whose behaviour is described by reference to a standard model <font colo... |
CSCDynamics | CSC function block whose behaviour is described by reference to a standard mo... |
CSCUserDefined | Current source converter (CSC) function block whose dynamic behaviour is desc... |
VSCDynamics | VSC function block whose behaviour is described by reference to a standard mo... |
VSCUserDefined | Voltage source converter (VSC) function block whose dynamic behaviour is desc... |
MechanicalLoadDynamics | Mechanical load function block whose behaviour is described by reference to a... |
MechanicalLoadUserDefined | Mechanical load function block whose dynamic behaviour is described by <font ... |
MechLoad1 | Mechanical load model type 1 |
OverexcitationLimiterDynamics | Overexcitation limiter function block whose behaviour is described by referen... |
OverexcitationLimiterUserDefined | Overexcitation limiter system function block whose dynamic behaviour is descr... |
OverexcLim2 | Different from LimIEEEOEL, LimOEL2 has a fixed pickup threshold and reduces t... |
OverexcLimIEEE | The over excitation limiter model is intended to represent the significant fe... |
OverexcLimX1 | Field voltage over excitation limiter |
OverexcLimX2 | Field voltage or current overexcitation limiter designed to protect the gener... |
PFVArControllerType1Dynamics | Power factor or VAr controller type 1 function block whose behaviour is descr... |
PFVArControllerType1UserDefined | Power factor or VAr controller type 1 function block whose dynamic behaviour ... |
PFVArType1IEEEPFController | IEEE PF controller type 1 which operates by moving the voltage reference dire... |
PFVArType1IEEEVArController | IEEE VAR controller type 1 which operates by moving the voltage reference dir... |
PFVArControllerType2Dynamics | Power factor or VAr controller type 2 function block whose behaviour is descr... |
PFVArControllerType2UserDefined | Power factor or VAr controller type 2 function block whose dynamic behaviour ... |
PFVArType2Common1 | Power factor / reactive power regulator |
PFVArType2IEEEPFController | IEEE PF controller type 2 which is a summing point type controller making up ... |
PFVArType2IEEEVArController | IEEE VAR controller type 2 which is a summing point type controller |
PowerSystemStabilizerDynamics | Power system stabilizer function block whose behaviour is described by refere... |
PowerSystemStabilizerUserDefined | Power system stabilizer function block whose dyn... |
Pss1 | Italian PSS with three inputs (speed, frequency, power) |
Pss1A | Single input power system stabilizer |
Pss2B | Modified IEEE PSS2B |
Pss2ST | PTI microprocessor-based stabilizer type 1 |
Pss5 | Detailed Italian PSS |
PssELIN2 | Power system stabilizer typically associated with ExcELIN2 (though PssIEEE2B ... |
PssIEEE1A | IEEE 421 |
PssIEEE2B | IEEE 421 |
PssIEEE3B | IEEE 421 |
PssIEEE4B | IEEE 421 |
PssPTIST1 | PTI microprocessor-based stabilizer type 1 |
PssPTIST3 | PTI microprocessor-based stabilizer type 3 |
PssRQB | Power system stabilizer type RQB |
PssSB4 | Power sensitive stabilizer model |
PssSH | SiemensTM “H infinity” power system stabilizer with generator elec... |
PssSK | Slovakian PSS with three inputs |
PssSTAB2A | Power system stabilizer part of an ABB excitation system |
PssWECC | Dual input power system stabilizer, based on IEEE type 2, with modified outpu... |
RotatingMachineDynamics | Abstract parent class for all synchronous and asynchronous machine standard m... |
AsynchronousMachineDynamics | Asynchronous machine whose behaviour is described by reference to a standard ... |
AsynchronousMachineEquivalentCircuit | The electrical equations of all variations of the asynchronous model are base... |
AsynchronousMachineTimeConstantReactance | Parameter details: |
AsynchronousMachineUserDefined | Asynchronous machine whose dynamic behaviour is described by a user-defined m... |
SynchronousMachineDynamics | Synchronous machine whose behaviour is described by reference to a standard m... |
SynchronousMachineDetailed | All synchronous machine detailed types use a subset of the same data paramete... |
SynchronousMachineEquivalentCircuit | The electrical equations for all variations of the synchronous models are bas... |
SynchronousMachineTimeConstantReactance | Synchronous machine detailed modelling types are defined by the combination o... |
SynchronousMachineSimplified | The simplified model represents a synchronous generator as a constant interna... |
SynchronousMachineUserDefined | Synchronous machine whose dynamic behaviour is described by a user-defined mo... |
StaticVarCompensatorDynamics | Static var compensator whose behaviour is described by reference to a standar... |
SVCUserDefined | Static var compensator (SVC) function block whose dynamic behaviour is descri... |
TurbineGovernorDynamics | Turbine-governor function block whose behaviour is described by reference to ... |
GovCT1 | General model for any prime mover with a PID governor, used primarily for com... |
GovCT2 | General governor with frequency-dependent fuel flow limit |
GovGAST | Single shaft gas turbine |
GovGAST1 | Modified single shaft gas turbine |
GovGAST2 | Gas turbine |
GovGAST3 | Generic turbogas with acceleration and temperature controller |
GovGAST4 | Generic turbogas |
GovGASTWD | Woodward™ gas turbine governor |
GovHydro1 | Basic hydro turbine governor |
GovHydro2 | IEEE hydro turbine governor with straightforward penstock configuration and h... |
GovHydro3 | Modified IEEE hydro governor-turbine |
GovHydro4 | Hydro turbine and governor |
GovHydroDD | Double derivative hydro governor and turbine |
GovHydroFrancis | Detailed hydro unit - Francis model |
GovHydroIEEE0 | IEEE simplified hydro governor-turbine model |
GovHydroIEEE2 | IEEE hydro turbine governor model represents plants with straightforward pens... |
GovHydroPelton | Detailed hydro unit - Pelton model |
GovHydroPID | PID governor and turbine |
GovHydroPID2 | Hydro turbine and governor |
GovHydroR | Fourth order lead-lag governor and hydro turbine |
GovHydroWEH | WoodwardTM electric hydro governor |
GovHydroWPID | WoodwardTM PID hydro governor |
GovSteam0 | A simplified steam turbine governor |
GovSteam1 | Steam turbine governor, based on the GovSteamIEEE1 (with optional deadband an... |
GovSteam2 | Simplified governor |
GovSteamBB | European governor model |
GovSteamEU | Simplified boiler and steam turbine with PID governor |
GovSteamFV2 | Steam turbine governor with reheat time constants and modelling of the effect... |
GovSteamFV3 | Simplified GovSteamIEEE1 steam turbine governor with Prmax limit and fast val... |
GovSteamFV4 | Detailed electro-hydraulic governor for steam unit |
GovSteamIEEE1 | IEEE steam turbine governor model |
GovSteamSGO | Simplified steam turbine governor |
TurbineGovernorUserDefined | Turbine-governor function block whose dynamic behaviour is described by <font... |
TurbineLoadControllerDynamics | Turbine load controller function block whose behaviour is described by refere... |
TurbineLoadControllerUserDefined | Turbine load controller function block whose dynamic behaviour is described b... |
TurbLCFB1 | Turbine load controller model developed by WECC |
UnderexcitationLimiterDynamics | Underexcitation limiter function block whose behaviour is described by refere... |
UnderexcitationLimiterUserDefined | Underexcitation limiter function block whose dynamic behaviour is described b... |
UnderexcLim2Simplified | Simplified type UEL2 underexcitation limiter |
UnderexcLimIEEE1 | Type UEL1 model which has a circular limit boundary when plotted in terms of ... |
UnderexcLimIEEE2 | Type UEL2 underexcitation limiter which has either a straight-line or multi-s... |
UnderexcLimX1 | Allis-Chalmers minimum excitation limiter |
UnderexcLimX2 | Westinghouse minimum excitation limiter |
VoltageAdjusterDynamics | Voltage adjuster function block whose behaviour is described by reference to ... |
VAdjIEEE | IEEE voltage adjuster which is used to represent the voltage adjuster in eith... |
VoltageAdjusterUserDefined | Voltage adjuster function block whose dynamic be... |
VoltageCompensatorDynamics | Voltage compensator function block whose behaviour is described by reference ... |
VCompIEEEType1 | Terminal voltage transducer and load compensator as def... |
VCompIEEEType2 | Terminal voltage transducer and load compensator as def... |
VoltageCompensatorUserDefined | Voltage compensator function block whose dynamic behaviour is described by <f... |
WindPlantDynamics | Parent class supporting relationships to wind turbines type 3 and type 4 and ... |
WindPlantIEC | Simplified IEC type plant level model |
WindPlantUserDefined | Wind plant function block whose dynamic behaviour is described by <font color... |
WindTurbineType1or2Dynamics | Parent class supporting relationships to wind turbines type 1 and type 2 and ... |
WindTurbineType1or2IEC | Parent class supporting relationships to IEC wind turbines type 1 and type 2 ... |
WindGenTurbineType1aIEC | Wind turbine IEC type 1A |
WindGenTurbineType1bIEC | Wind turbine IEC type 1B |
WindGenTurbineType2IEC | Wind turbine IEC type 2 |
WindType1or2UserDefined | Wind type 1 or type 2 function block whose dynamic behaviour is described by ... |
WindTurbineType3or4Dynamics | Parent class supporting relationships to wind turbines type 3 and type 4 and ... |
WindTurbineType3or4IEC | Parent class supporting relationships to IEC wind turbines type 3 and type 4 ... |
WindTurbineType3IEC | Parent class supporting relationships to IEC wind turbines type 3 including t... |
WindTurbineType4IEC | Parent class supporting relationships to IEC wind turbines type 4 including t... |
WindTurbineType4aIEC | Wind turbine IEC type 4A |
WindTurbineType4bIEC | Wind turbine IEC type 4B |
WindType3or4UserDefined | Wind type 3 or type 4 function block whose dynamic behaviour is described by ... |
GenICompensationForGenJ | Resistive and reactive components of compensation for generator associated wi... |
LoadDynamics | Load whose behaviour is described by reference to a standard model <font colo... |
LoadAggregate | Aggregate loads are used to represent all or part of the real and reactive lo... |
LoadComposite | Combined static load and induction motor load effects |
LoadGenericNonLinear | Generic non-linear dynamic (GNLD) load |
LoadUserDefined | Load whose dynamic behaviour is described by a user-defined model |
LoadMotor | Aggregate induction motor load |
LoadStatic | General static load |
PowerSystemResource | A power system resource (PSR) can be an item of equipment such as a switch, a... |
Equipment | The parts of a power system that are physical devices, electronic or mechanic... |
ConductingEquipment | The parts of the AC power system that are designed to carry current or that a... |
ACDCConverter | A unit with valves for three phases, together with unit control equipment, es... |
CsConverter | DC side of the current source converter (CSC) |
VsConverter | DC side of the voltage source converter (VSC) |
EnergyConnection | A connection of energy generation or consumption on the power system model |
EnergyConsumer | Generic user of energy - a point of consumption on the power system model |
RegulatingCondEq | A type of conducting equipment that can regulate a quantity (i |
PowerElectronicsConnection | A connection to the AC network for energy production or consumption that uses... |
RotatingMachine | A rotating machine which may be used as a generator or motor |
AsynchronousMachine | A rotating machine whose shaft rotates asynchronously with the electrical fie... |
SynchronousMachine | An electromechanical device that operates with shaft rotating synchronously w... |
StaticVarCompensator | A facility for providing variable and controllable shunt reactive power |
RemoteInputSignal | Supports connection to a terminal associated with a remote bus from which an ... |
WindAeroConstIEC | Constant aerodynamic torque model which assumes that the aerodynamic torque i... |
WindAeroOneDimIEC | One-dimensional aerodynamic model |
WindAeroTwoDimIEC | Two-dimensional aerodynamic model |
WindContCurrLimIEC | Current limitation model |
WindContPitchAngleIEC | Pitch angle control model |
WindContPType3IEC | P control model type 3 |
WindContPType4aIEC | P control model type 4A |
WindContPType4bIEC | P control model type 4B |
WindContQIEC | Q control model |
WindContQLimIEC | Constant Q limitation model |
WindContQPQULimIEC | QP and QU limitation model |
WindContRotorRIEC | Rotor resistance control model |
WindDynamicsLookupTable | Look up table for the purpose of wind standard models |
WindGenType3IEC | Parent class supporting relationships to IEC wind turbines type 3 generator m... |
WindGenType3aIEC | IEC type 3A generator set model |
WindGenType3bIEC | IEC type 3B generator set model |
WindGenType4IEC | IEC type 4 generator set model |
WindMechIEC | Two mass model |
WindPitchContPowerIEC | Pitch control power model |
WindPlantFreqPcontrolIEC | Frequency and active power controller model |
WindPlantReactiveControlIEC | Simplified plant voltage and reactive power control model for use with type 3... |
WindProtectionIEC | The grid protection model includes protection against over- and under-voltage... |
WindRefFrameRotIEC | Reference frame rotation model |
Length | Unit of length |
ProprietaryParameterDynamics | Supports definition of one or more parameters of several different datatypes ... |
PU | Per Unit - a positive or negative value referred to a defined base |
Seconds | Time, in seconds |
Temperature | Value of temperature in degrees Celsius |
VolumeFlowRate | Volume per time |