EnergyConnection

A connection of energy generation or consumption on the power system model.

Type

Class

URI

cim:EnergyConnection

CIM standard (perspective)

IEC61970 (Grid)

Slots

Associated classes
Figure 1. Associated classes
Name Cardinality Type Description

m_rid

1

string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

description

0..1

string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

location

0..1

Location

Location of this power system resource.

operational_limit_set

0..*

OperationalLimitSet

The operational limit sets associated with this equipment.

terminals

0..*

Terminal

Conducting equipment have terminals that may be connected to other conducting equipment terminals via connectivity nodes or topological nodes.

usage_points

0..*

UsagePoint

All usage points connected to the electrical grid through this equipment.


description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

URI

cim:IdentifiedObject.description

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

location

Location of this power system resource.

URI

cim:PowerSystemResource.Location

Cardinality

0..1

Type

Location

Inherited from

PowerSystemResource

m_rid

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

URI

cim:IdentifiedObject.mRID

Cardinality

1

Type

string

Inherited from

IdentifiedObject

operational_limit_set

The operational limit sets associated with this equipment.

URI

cim:Equipment.OperationalLimitSet

Cardinality

0..*

Type

OperationalLimitSet

Inherited from

Equipment

terminals

Conducting equipment have terminals that may be connected to other conducting equipment terminals via connectivity nodes or topological nodes.

URI

cim:ConductingEquipment.Terminals

Cardinality

0..*

Type

Terminal

Inherited from

ConductingEquipment

usage_points

All usage points connected to the electrical grid through this equipment.

URI

cim:Equipment.UsagePoints

Cardinality

0..*

Type

UsagePoint

Inherited from

Equipment