UsagePoint
Logical or physical point in the network to which readings or events may be attributed. Used at the place where a physical or virtual meter may be located; however, it is not required that a meter be present.
Type |
Class |
---|---|
URI? |
|
CIM standard (perspective) |
IEC61968 (Enterprise) |
Slots
Name | Cardinality? | Type | Description |
---|---|---|---|
1 |
If true, this usage point is virtual, i.e., no physical location exists in the network where a meter could be located to collect the meter readings. For example, one may define a virtual usage point to serve as an aggregation of usage for all of a company's premises distributed widely across the distribution territory. Otherwise, the usage point is physical, i.e., there is a logical point in the network where a meter could be located to collect meter readings. |
||
0..1 |
The attribute is used for an exchange of the EAN code (European Article Number). The length of the string is 18 characters as defined by the EAN code. For details on EAN scheme please refer to the [Codebesluit toekenning EAN-codes elektriciteit](https://www.acm.nl/nl/publicaties/codebesluit-toekenning-ean-codes-elektriciteit). |
||
0..1 |
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. |
||
0..1 |
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. |
||
0..* |
All names of this identified object. |
description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
URI |
|
---|---|
Cardinality? |
0..1 |
Type |
|
Inherited from |
european_article_number_ean
The attribute is used for an exchange of the EAN code (European Article Number). The length of the string is 18 characters as defined by the EAN code. For details on EAN scheme please refer to the [Codebesluit toekenning EAN-codes elektriciteit](https://www.acm.nl/nl/publicaties/codebesluit-toekenning-ean-codes-elektriciteit).
URI |
|||||
---|---|---|---|---|---|
Cardinality? |
0..1 |
||||
Type |
|||||
Glossary mappings? |
|
is_virtual
If true, this usage point is virtual, i.e., no physical location exists in the network where a meter could be located to collect the meter readings. For example, one may define a virtual usage point to serve as an aggregation of usage for all of a company's premises distributed widely across the distribution territory. Otherwise, the usage point is physical, i.e., there is a logical point in the network where a meter could be located to collect meter readings.
URI |
|
---|---|
Cardinality? |
1 |
Type |
m_rid
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
URI |
|
---|---|
Cardinality? |
0..1 |
Type |
|
Inherited from |
names
All names of this identified object.
URI |
|
---|---|
Cardinality? |
0..* |
Type |
|
Inherited from |