EnergyConsumer

Generic user of energy - a point of consumption on the power system model. EnergyConsumer.pfixed, .qfixed, .pfixedPct and .qfixedPct have meaning only if there is no LoadResponseCharacteristic associated with EnergyConsumer or if LoadResponseCharacteristic.exponentModel is set to False.

Type

Class

URI?

cim:EnergyConsumer

CIM standard (perspective)

IEC61970 (Grid)

Slots

Associated classes
Figure 1. Associated classes
Name Cardinality? Type Description

m_rid

1

string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

description

0..1

string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

location

0..1

Location

Location of this power system resource.

names

0..*

Name

All names of this identified object.

operational_limit_set

0..*

OperationalLimitSet

The operational limit sets associated with this equipment.

usage_points

0..*

UsagePoint

All usage points connected to the electrical grid through this equipment.


description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

URI

cim:IdentifiedObject.description

Cardinality?

0..1

Type

string

Inherited from

IdentifiedObject

location

Location of this power system resource.

URI

cim:PowerSystemResource.Location

Cardinality?

0..1

Type

Location

Inherited from

PowerSystemResource

m_rid

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

URI

cim:IdentifiedObject.mRID

Cardinality?

1

Type

string

Inherited from

IdentifiedObject

names

All names of this identified object.

URI

cim:IdentifiedObject.Names

Cardinality?

0..*

Type

Name

Inherited from

IdentifiedObject

operational_limit_set

The operational limit sets associated with this equipment.

URI

cim:Equipment.OperationalLimitSet

Cardinality?

0..*

Type

OperationalLimitSet

Inherited from

Equipment

usage_points

All usage points connected to the electrical grid through this equipment.

URI

cim:Equipment.UsagePoints

Cardinality?

0..*

Type

UsagePoint

Inherited from

Equipment