PowerTransformer
An electrical device consisting of two or more coupled windings, with or without a magnetic core, for introducing mutual coupling between electric circuits. Transformers can be used to control voltage and phase shift (active power flow). A power transformer may be composed of separate transformer tanks that need not be identical. A power transformer can be modelled with or without tanks and is intended for use in both balanced and unbalanced representations. A power transformer typically has two terminals, but may have one (grounding), three or more terminals. The inherited association ConductingEquipment.BaseVoltage should not be used. The association from TransformerEnd to BaseVoltage should be used instead.
Type |
Class |
---|---|
URI? |
|
CIM standard (perspective) |
IEC61970 (Grid) |
Slots
Name | Cardinality? | Type | Description |
---|---|---|---|
1..* |
The ends of this power transformer. |
||
1 |
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. |
||
0..1 |
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. |
||
0..1 |
Location of this power system resource. |
||
0..* |
All names of this identified object. |
||
0..* |
The operational limit sets associated with this equipment. |
||
0..* |
All usage points connected to the electrical grid through this equipment. |
description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
URI |
|
---|---|
Cardinality? |
0..1 |
Type |
|
Inherited from |
location
Location of this power system resource.
URI |
|
---|---|
Cardinality? |
0..1 |
Type |
|
Inherited from |
m_rid
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
URI |
|
---|---|
Cardinality? |
1 |
Type |
|
Inherited from |
names
All names of this identified object.
URI |
|
---|---|
Cardinality? |
0..* |
Type |
|
Inherited from |
operational_limit_set
The operational limit sets associated with this equipment.
URI |
|
---|---|
Cardinality? |
0..* |
Type |
|
Inherited from |
power_transformer_end
The ends of this power transformer.
URI |
|
---|---|
Cardinality? |
1..* |
Type |
usage_points
All usage points connected to the electrical grid through this equipment.
URI |
|
---|---|
Cardinality? |
0..* |
Type |
|
Inherited from |