Analog

Analog represents an analog Measurement.

Type

Class

URI

cim:Analog

CIM standard (perspective)

IEC61970 (Grid)

Class hierarchy

Slots

Associated classes
Figure 1. Associated classes
Name Type Description Inherited from

AnalogValues

0..*
AnalogValue

The values connected to this measurement.

n/a

positiveFlowIn

0..1
boolean

If true then this measurement is an active power, reactive power or current with the convention that a positive value...

n/a

PowerSystemResource

0..1
PowerSystemResource

The power system resource that contains the measurement.

Measurement

Terminal

0..1
ACDCTerminal

One or more measurements may be associated with a terminal in the network.

Measurement

measurementType

0..1
string

Specifies the type of measurement. For example, this specifies if the measurement represents an indoor temperature, outdoor...

Measurement

unitMultiplier

0..1
UnitMultiplier

The unit multiplier of the measured quantity.

Measurement

unitSymbol

0..1
UnitSymbol

The unit of measure of the measured quantity.

Measurement

description

0..1
string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to...

IdentifiedObject

europeanArticleNumberEAN

0..1
string

The attribute is used for an exchange of the EAN code (European Article Number). The length of the string is 16 characters...

IdentifiedObject

mRID

0..1
string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is...

IdentifiedObject


AnalogValues

The values connected to this measurement.

URI

cim:Analog.AnalogValues

Cardinality

0..*

Type

AnalogValue

description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

URI

cim:IdentifiedObject.description

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

europeanArticleNumberEAN

The attribute is used for an exchange of the EAN code (European Article Number). The length of the string is 16 characters as defined by the EAN code.

URI

nl:IdentifiedObject.europeanArticleNumberEAN

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

measurementType

Specifies the type of measurement. For example, this specifies if the measurement represents an indoor temperature, outdoor temperature, bus voltage, line flow, etc. When the measurementType is set to "Specialization", the type of Measurement is defined in more detail by the specialized class which inherits from Measurement.

URI

cim:Measurement.measurementType

Cardinality

0..1

Type

string

Inherited from

Measurement

mRID

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

URI

cim:IdentifiedObject.mRID

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

positiveFlowIn

If true then this measurement is an active power, reactive power or current with the convention that a positive value measured at the Terminal means power is flowing into the related PowerSystemResource.

URI

cim:Analog.positiveFlowIn

Cardinality

0..1

Type

boolean

PowerSystemResource

The power system resource that contains the measurement.

URI

cim:Measurement.PowerSystemResource

Cardinality

0..1

Type

PowerSystemResource

Inherited from

Measurement

Terminal

One or more measurements may be associated with a terminal in the network.

URI

cim:Measurement.Terminal

Cardinality

0..1

Type

ACDCTerminal

Inherited from

Measurement

unitMultiplier

The unit multiplier of the measured quantity.

URI

cim:Measurement.unitMultiplier

Cardinality

0..1

Type

UnitMultiplier

Inherited from

Measurement

unitSymbol

The unit of measure of the measured quantity.

URI

cim:Measurement.unitSymbol

Cardinality

0..1

Type

UnitSymbol

Inherited from

Measurement

Used by

Source class Slot name

AnalogValue

Analog