BaseVoltage
Defines a system base voltage which is referenced.
Type |
Class |
||||
|---|---|---|---|---|---|
URI |
|
||||
CIM standard (perspective) |
IEC61970 (Grid) |
||||
Glossary mappings |
|
Slots
| Name | Type | Description | Inherited from |
|---|---|---|---|
0..* |
All conducting equipment with this base voltage. Use only when there is no voltage level container used and only one base... |
n/a |
|
0..* |
Transformer ends at the base voltage. This is essential for PU calculation. |
n/a |
|
0..* |
The voltage levels having this base voltage. |
n/a |
|
0..1 |
The power system resource's base voltage. Shall be a positive value and not zero. |
n/a |
|
0..* |
All names of this identified object. |
||
0..1 |
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to... |
||
0..1 |
The attribute is used for an exchange of the EAN code (European Article Number). The length of the string is 16 characters... |
||
0..1 |
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is... |
||
0..1 |
The name is any free human readable and possibly non unique text naming the object. |
ConductingEquipment
All conducting equipment with this base voltage. Use only when there is no voltage level container used and only one base voltage applies. For example, not used for transformers.
URI |
|
|---|---|
Cardinality |
0..* |
Type |
description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
europeanArticleNumberEAN
The attribute is used for an exchange of the EAN code (European Article Number). The length of the string is 16 characters as defined by the EAN code.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
mRID
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
name
The name is any free human readable and possibly non unique text naming the object.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Names
All names of this identified object.
URI |
|
|---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
nominalVoltage
The power system resource's base voltage. Shall be a positive value and not zero.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
TransformerEnds
Transformer ends at the base voltage. This is essential for PU calculation.
URI |
|
|---|---|
Cardinality |
0..* |
Type |