OperationalLimitSet
A set of limits associated with equipment. Sets of limits might apply to a specific temperature, or season for example. A set of limits may contain different severities of limit levels that would apply to the same equipment. The set may contain limits of different types such as apparent power and current limits or high and low voltage limits that are logically applied together as a set.
Type |
Class |
|---|---|
URI |
|
CIM standard (perspective) |
IEC61970 (Grid) |
Slots
| Name | Type | Description | Inherited from |
|---|---|---|---|
0..1 |
The equipment to which the limit set applies. |
n/a |
|
0..* |
Values of equipment limits. |
n/a |
|
0..1 |
The terminal where the operational limit set apply. |
n/a |
|
0..* |
All names of this identified object. |
||
0..1 |
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to... |
||
0..1 |
The attribute is used for an exchange of the EAN code (European Article Number). The length of the string is 16 characters... |
||
0..1 |
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is... |
||
0..1 |
The name is any free human readable and possibly non unique text naming the object. |
description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Equipment
The equipment to which the limit set applies.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
europeanArticleNumberEAN
The attribute is used for an exchange of the EAN code (European Article Number). The length of the string is 16 characters as defined by the EAN code.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
mRID
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
name
The name is any free human readable and possibly non unique text naming the object.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Names
All names of this identified object.
URI |
|
|---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
OperationalLimitValue
Values of equipment limits.
URI |
|
|---|---|
Cardinality |
0..* |
Type |