Substation
A collection of equipment for purposes other than generation or utilization, through which electric energy in bulk is passed for the purposes of switching or modifying its characteristics.
Type |
Class |
---|---|
URI |
|
CIM standard (perspective) |
IEC61970 (Grid) |
Slots
Name | Type | Description | Inherited from |
---|---|---|---|
The SubGeographicalRegion containing the substation. |
n/a |
||
0..* |
The voltage levels within this substation. |
n/a |
|
0..* |
Contained equipment. |
||
0..* |
Connectivity nodes which belong to this connectivity node container. |
||
0..1 |
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to... |
||
0..1 |
The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16... |
||
1 |
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is... |
||
1 |
The name is any free human readable and possibly non unique text naming the object. |
||
0..1 |
The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. |
ConnectivityNodes
Connectivity nodes which belong to this connectivity node container.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
energyIdentCodeEic
The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Equipments
Contained equipment.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
mRID
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
URI |
|
---|---|
Cardinality |
1 |
Type |
|
Inherited from |
name
The name is any free human readable and possibly non unique text naming the object.
URI |
|
---|---|
Cardinality |
1 |
Type |
|
Inherited from |
Region
The SubGeographicalRegion containing the substation.
URI |
|
---|---|
Cardinality |
1 |
Type |
shortName
The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |