Switch
A generic device designed to close, or open, or both, one or more electric circuits. All switches are two terminal devices including grounding switches. The ACDCTerminal.connected at the two sides of the switch shall not be considered for assessing switch connectivity, i.e. only Switch.open, .normalOpen and .locked are relevant.
Type |
Class |
|---|---|
URI |
|
CIM standard (perspective) |
IEC61970 (Grid) |
Slots
| Name | Type | Description | Inherited from |
|---|---|---|---|
0..1 |
The attribute is used in cases when no Measurement for the status value is present. If the Switch has a status measurement... |
n/a |
|
0..1 |
Base voltage of this conducting equipment. Use only when there is no voltage level container used and only one base voltage... |
||
0..* |
Conducting equipment have terminals that may be connected to other conducting equipment terminals via connectivity nodes or... |
||
0..1 |
Container of this equipment. |
||
0..* |
The operational limit sets associated with this equipment. |
||
0..1 |
The aggregate flag provides an alternative way of representing an aggregated (equivalent) element. It is applicable in cases... |
||
0..1 |
Specifies the availability of the equipment. True means the equipment is available for topology processing, which determines... |
||
0..1 |
The equipment is enabled to participate in network analysis. If unspecified, the value is assumed to be true. |
||
0..1 |
Specifies the availability of the equipment under normal operating conditions. True means the equipment is available for... |
||
0..1 |
Custom classification for this power system resource. |
||
0..* |
All names of this identified object. |
||
0..1 |
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to... |
||
0..1 |
The attribute is used for an exchange of the EAN code (European Article Number). The length of the string is 16 characters... |
||
0..1 |
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is... |
||
0..1 |
The name is any free human readable and possibly non unique text naming the object. |
aggregate
The aggregate flag provides an alternative way of representing an aggregated (equivalent) element. It is applicable in cases when the dedicated classes for equivalent equipment do not have all of the attributes necessary to represent the required level of detail. In case the flag is set to “true” the single instance of equipment represents multiple pieces of equipment that have been modelled together as an aggregate equivalent obtained by a network reduction procedure. Examples would be power transformers or synchronous machines operating in parallel modelled as a single aggregate power transformer or aggregate synchronous machine. The attribute is not used for EquivalentBranch, EquivalentShunt and EquivalentInjection.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
BaseVoltage
Base voltage of this conducting equipment. Use only when there is no voltage level container used and only one base voltage applies. For example, not used for transformers.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
EquipmentContainer
Container of this equipment.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
europeanArticleNumberEAN
The attribute is used for an exchange of the EAN code (European Article Number). The length of the string is 16 characters as defined by the EAN code.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
inService
Specifies the availability of the equipment. True means the equipment is available for topology processing, which determines if the equipment is energized or not. False means that the equipment is treated by network applications as if it is not in the model.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
mRID
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
name
The name is any free human readable and possibly non unique text naming the object.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Names
All names of this identified object.
URI |
|
|---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
networkAnalysisEnabled
The equipment is enabled to participate in network analysis. If unspecified, the value is assumed to be true.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
normallyInService
Specifies the availability of the equipment under normal operating conditions. True means the equipment is available for topology processing, which determines if the equipment is energized or not. False means that the equipment is treated by network applications as if it is not in the model.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
normalOpen
The attribute is used in cases when no Measurement for the status value is present. If the Switch has a status measurement the Discrete.normalValue is expected to match with the Switch.normalOpen.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
OperationalLimitSet
The operational limit sets associated with this equipment.
URI |
|
|---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
PSRType
Custom classification for this power system resource.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |