Equipment
The parts of a power system that are physical devices, electronic or mechanical.
Type |
Class |
|---|---|
URI |
|
CIM standard (perspective) |
IEC61970 (Grid) |
Slots
| Name | Type | Description | Inherited from |
|---|---|---|---|
0..1 |
Container of this equipment. |
n/a |
|
0..* |
The operational limit sets associated with this equipment. |
n/a |
|
0..1 |
The aggregate flag provides an alternative way of representing an aggregated (equivalent) element. It is applicable in cases... |
n/a |
|
0..1 |
Specifies the availability of the equipment. True means the equipment is available for topology processing, which determines... |
n/a |
|
0..1 |
The equipment is enabled to participate in network analysis. If unspecified, the value is assumed to be true. |
n/a |
|
0..1 |
Specifies the availability of the equipment under normal operating conditions. True means the equipment is available for... |
n/a |
|
0..1 |
Custom classification for this power system resource. |
||
0..* |
All names of this identified object. |
||
0..1 |
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to... |
||
0..1 |
The attribute is used for an exchange of the EAN code (European Article Number). The length of the string is 16 characters... |
||
0..1 |
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is... |
||
0..1 |
The name is any free human readable and possibly non unique text naming the object. |
aggregate
The aggregate flag provides an alternative way of representing an aggregated (equivalent) element. It is applicable in cases when the dedicated classes for equivalent equipment do not have all of the attributes necessary to represent the required level of detail. In case the flag is set to “true” the single instance of equipment represents multiple pieces of equipment that have been modelled together as an aggregate equivalent obtained by a network reduction procedure. Examples would be power transformers or synchronous machines operating in parallel modelled as a single aggregate power transformer or aggregate synchronous machine. The attribute is not used for EquivalentBranch, EquivalentShunt and EquivalentInjection.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
EquipmentContainer
Container of this equipment.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
europeanArticleNumberEAN
The attribute is used for an exchange of the EAN code (European Article Number). The length of the string is 16 characters as defined by the EAN code.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
inService
Specifies the availability of the equipment. True means the equipment is available for topology processing, which determines if the equipment is energized or not. False means that the equipment is treated by network applications as if it is not in the model.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
mRID
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
name
The name is any free human readable and possibly non unique text naming the object.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Names
All names of this identified object.
URI |
|
|---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
networkAnalysisEnabled
The equipment is enabled to participate in network analysis. If unspecified, the value is assumed to be true.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
normallyInService
Specifies the availability of the equipment under normal operating conditions. True means the equipment is available for topology processing, which determines if the equipment is energized or not. False means that the equipment is treated by network applications as if it is not in the model.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
OperationalLimitSet
The operational limit sets associated with this equipment.
URI |
|
|---|---|
Cardinality |
0..* |
Type |