BasicIntervalSchedule

Schedule of values at points in time.

Type

Class

URI

cim:BasicIntervalSchedule

CIM standard (perspective)

IEC61970 (Grid)

Class hierarchy

Slots

Name Type Description Inherited from

startTime

1
date

The time for the first time point. The value can be a time of day, not a specific date.

n/a

value1Unit

1
UnitSymbol

Value1 units of measure.

n/a

value2Unit

0..1
UnitSymbol

Value2 units of measure.

n/a

description

0..1
string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to...

IdentifiedObject

energyIdentCodeEic

0..1
string

The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16...

IdentifiedObject

mRID

1
string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is...

IdentifiedObject

name

1
string

The name is any free human readable and possibly non unique text naming the object.

IdentifiedObject

shortName

0..1
string

The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum.

IdentifiedObject


description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

URI

cim:IdentifiedObject.description

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

energyIdentCodeEic

The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site.

URI

eu:IdentifiedObject.energyIdentCodeEic

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

mRID

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

URI

cim:IdentifiedObject.mRID

Cardinality

1

Type

string

Inherited from

IdentifiedObject

name

The name is any free human readable and possibly non unique text naming the object.

URI

cim:IdentifiedObject.name

Cardinality

1

Type

string

Inherited from

IdentifiedObject

shortName

The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum.

URI

eu:IdentifiedObject.shortName

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

startTime

The time for the first time point. The value can be a time of day, not a specific date.

URI

cim:BasicIntervalSchedule.startTime

Cardinality

1

Type

date

value1Unit

Value1 units of measure.

URI

cim:BasicIntervalSchedule.value1Unit

Cardinality

1

Type

UnitSymbol

value2Unit

Value2 units of measure.

URI

cim:BasicIntervalSchedule.value2Unit

Cardinality

0..1

Type

UnitSymbol

Used by

This class is not used by any other classes as the range of a slot.