LoadBreakSwitch

A mechanical switching device capable of making, carrying, and breaking currents under normal operating conditions.

Type

Class

URI

cim:LoadBreakSwitch

CIM standard (perspective)

IEC61970 (Grid)

Slots

Associated classes
Figure 1. Associated classes
Name Type Description Inherited from

normalOpen

1
boolean

The attribute is used in cases when no Measurement for the status value is present. If the Switch has a status measurement...

Switch

ratedCurrent

0..1
CurrentFlow

The maximum continuous current carrying capacity in amps governed by the device material and construction. The attribute...

Switch

retained

1
boolean

Branch is retained in the topological solution. The flow through retained switches will normally be calculated in power flow.

Switch

BaseVoltage

0..1
BaseVoltage

Base voltage of this conducting equipment. Use only when there is no voltage level container used and only one base voltage...

ConductingEquipment

Terminals

0..*
Terminal

Conducting equipment have terminals that may be connected to other conducting equipment terminals via connectivity nodes or...

ConductingEquipment

EquipmentContainer

0..1
EquipmentContainer

Container of this equipment.

Equipment

aggregate

0..1
boolean

The aggregate flag provides an alternative way of representing an aggregated (equivalent) element. It is applicable in cases...

Equipment

normallyInService

0..1
boolean

Specifies the availability of the equipment under normal operating conditions. True means the equipment is available for...

Equipment

description

0..1
string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to...

IdentifiedObject

energyIdentCodeEic

0..1
string

The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16...

IdentifiedObject

mRID

1
string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is...

IdentifiedObject

name

1
string

The name is any free human readable and possibly non unique text naming the object.

IdentifiedObject

shortName

0..1
string

The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum.

IdentifiedObject


aggregate

The aggregate flag provides an alternative way of representing an aggregated (equivalent) element. It is applicable in cases when the dedicated classes for equivalent equipment do not have all of the attributes necessary to represent the required level of detail. In case the flag is set to “true” the single instance of equipment represents multiple pieces of equipment that have been modelled together as an aggregate equivalent obtained by a network reduction procedure. Examples would be power transformers or synchronous machines operating in parallel modelled as a single aggregate power transformer or aggregate synchronous machine. The attribute is not used for EquivalentBranch, EquivalentShunt and EquivalentInjection.

URI

cim:Equipment.aggregate

Cardinality

0..1

Type

boolean

Inherited from

Equipment

BaseVoltage

Base voltage of this conducting equipment. Use only when there is no voltage level container used and only one base voltage applies. For example, not used for transformers.

URI

cim:ConductingEquipment.BaseVoltage

Cardinality

0..1

Type

BaseVoltage

Inherited from

ConductingEquipment

description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

URI

cim:IdentifiedObject.description

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

energyIdentCodeEic

The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site.

URI

eu:IdentifiedObject.energyIdentCodeEic

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

EquipmentContainer

Container of this equipment.

URI

cim:Equipment.EquipmentContainer

Cardinality

0..1

Type

EquipmentContainer

Inherited from

Equipment

mRID

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

URI

cim:IdentifiedObject.mRID

Cardinality

1

Type

string

Inherited from

IdentifiedObject

name

The name is any free human readable and possibly non unique text naming the object.

URI

cim:IdentifiedObject.name

Cardinality

1

Type

string

Inherited from

IdentifiedObject

normallyInService

Specifies the availability of the equipment under normal operating conditions. True means the equipment is available for topology processing, which determines if the equipment is energized or not. False means that the equipment is treated by network applications as if it is not in the model.

URI

cim:Equipment.normallyInService

Cardinality

0..1

Type

boolean

Inherited from

Equipment

normalOpen

The attribute is used in cases when no Measurement for the status value is present. If the Switch has a status measurement the Discrete.normalValue is expected to match with the Switch.normalOpen.

URI

cim:Switch.normalOpen

Cardinality

1

Type

boolean

Inherited from

Switch

ratedCurrent

The maximum continuous current carrying capacity in amps governed by the device material and construction. The attribute shall be a positive value.

URI

cim:Switch.ratedCurrent

Cardinality

0..1

Type

CurrentFlow

Inherited from

Switch

retained

Branch is retained in the topological solution. The flow through retained switches will normally be calculated in power flow.

URI

cim:Switch.retained

Cardinality

1

Type

boolean

Inherited from

Switch

shortName

The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum.

URI

eu:IdentifiedObject.shortName

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

Terminals

Conducting equipment have terminals that may be connected to other conducting equipment terminals via connectivity nodes or topological nodes.

URI

cim:ConductingEquipment.Terminals

Cardinality

0..*

Type

Terminal

Inherited from

ConductingEquipment

Used by