ActivePower

Product of RMS value of the voltage and the RMS value of the in-phase component of the current.

Type

CIM data type class

URI

cim:ActivePower

CIM standard (perspective)

IEC61970 (Grid)

Slots

Name Type Description

value

0..1
float

n/a

multiplier

0..1
UnitMultiplier

n/a

unit

0..1
UnitSymbol

n/a

Used by

Source class Slot name

ACDCConverter

targetPpcc

ActivePowerLimit

value

AreaReserveSpec

spinningReserveReqt

AsynchronousMachine

ratedMechanicalPower

BlockDispatchOrder

p

BranchGroup

minimumActivePower

CAESPlant

ratedCapacityP

CogenerationPlant

ratedP

CombinedCyclePlant

combCyclePlantRating

ControlArea

pTolerance

CurrentTransformer

coreBurden

DispatchInstReply

clearedMW

DistributedResourceActualEvent

totalPowerAdjustment

DopInstruction

mwDOP

EnergyConsumer

pfixed

EnergyConsumerPhase

pfixed

EnergyGroup

p

EnergySource

pMin

EnergyTransaction

receiptPointP

EquivalentInjection

p

ExternalNetworkInjection

p

Flowgate

importMWRating

FossilFuel

lowBreakpointP

FrequencyConverter

minP

FTR

baseEnergy

GeneralClearingResults

loadForecast

GeneratingBid

minEmergencyMW

GeneratingUnit

ratedNetMaxP

GeneratorTypeAsset

minP

GovCT1

mwbase

GovCT2

mwbase

GovGAST

mwbase

GovGAST1

mwbase

GovGAST2

trate

GovGASTWD

trate

GovHydro1

mwbase

GovHydro2

mwbase

GovHydro3

mwbase

GovHydro4

mwbase

GovHydroDD

mwbase

GovHydroIEEE0

mwbase

GovHydroIEEE2

mwbase

GovHydroPID

mwbase

GovHydroPID2

mwbase

GovHydroR

mwbase

GovHydroWEH

mwbase

GovHydroWPID

mwbase

GovSteam0

mwbase

GovSteam1

mwbase

GovSteamCC

mwbase

GovSteamEU

mwbase

GovSteamFV2

mwbase

GovSteamFV3

mwbase

GovSteamIEEE1

mwbase

GovSteamSGO

mwbase

HeatInputCurve

auxPowerOffset

HydroPowerPlant

pumpRatedP

HydroPump

pumpPowerAtMinHead

HydroTurbine

turbineRating

LoadBid

minLoadReduction

OrgPnodeAllocation

maxMWAllocation

PowerElectronicsConnection

p

PowerElectronicsConnectionPhase

p

PowerElectronicsUnit

minP

ProfileData

capacityLevel

ProportionalDistributionComponent

distributionFactor

RegisteredControllableLoad

minLoadReduction

RegisteredGenerator

nameplateCapacity

RegulatingLimit

lowLimit

RemoteConnectDisconnectInfo

powerLimit

RotatingMachine

p

ScheduledActivePowerLimitValue

value

SecurityConstraints

minMW

SecurityConstraintsClearing

mwLimit

StartupModel

stbyAuxP

Streetlight

lightRating

SvInjection

pInjection

SvPowerFlow

p

SynchronousMachine

condenserP

TiePoint

tiePointMWRating

TopologicalNode

pInjection

TransmissionPath

totalTransferCapability

TurbLCFB1

pmwset

UnitInitialConditions

resourceMW

UsagePoint