CurrentTransformerInfo
Properties of current transformer asset.
Type |
Class |
---|---|
URI |
|
CIM standard (perspective) |
IEC61968 (Enterprise) |
Slots
Name | Cardinality | Type | Description |
---|---|---|---|
1 |
Dataset containing the data objects. |
||
0..1 |
CT accuracy classification. |
||
0..1 |
Accuracy limit. |
||
0..1 |
Number of cores. |
||
0..1 |
n/a |
||
0..1 |
Maximum primary current where the CT still displays linear characteristicts. |
||
0..1 |
Maximum voltage across the secondary terminals where the CT still displays linear characteristicts. |
||
0..1 |
Maximum ratio between the primary and secondary current. |
||
0..1 |
Nominal ratio between the primary and secondary current; i.e. 100:5. |
||
0..1 |
Full load secondary (FLS) rating for primary winding. |
||
0..1 |
Ratio for the primary winding tap changer. |
||
0..1 |
Rated current on the primary side. |
||
0..1 |
Full load secondary (FLS) rating for secondary winding. |
||
0..1 |
Ratio for the secondary winding tap changer. |
||
0..1 |
Full load secondary (FLS) rating for tertiary winding. |
||
0..1 |
Ratio for the tertiary winding tap changer. |
||
0..1 |
Usage: eg. metering, protection, etc. |
||
0..1 |
Asset information (nameplate) for this catalog asset type. |
||
0..1 |
Product asset model which conforms to this catalog asset type. |
||
0..1 |
The single CIM data object in the appropriate dataset context. |
||
0..1 |
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time. |
||
0..1 |
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. |
||
0..1 |
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. |
||
0..1 |
The name is any free human readable and possibly non unique text naming the object. |
||
0..* |
All assets described by this data. |
||
0..* |
The diagram objects that are associated with the domain object. |
||
0..* |
All names of this identified object. |
||
0..* |
All power system resources with this datasheet information. |
||
0..* |
Data objects registered. |
accuracyClass
CT accuracy classification.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
aliasName
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Assets
All assets described by this data.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
CatalogAssetType
Asset information (nameplate) for this catalog asset type.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
DiagramObjects
The diagram objects that are associated with the domain object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
InstanceSet
Dataset containing the data objects.
URI |
|
---|---|
Cardinality |
1 |
Type |
|
Inherited from |
kneePointCurrent
Maximum primary current where the CT still displays linear characteristicts.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
kneePointVoltage
Maximum voltage across the secondary terminals where the CT still displays linear characteristicts.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
maxRatio
Maximum ratio between the primary and secondary current.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
mRID
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
name
The name is any free human readable and possibly non unique text naming the object.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Names
All names of this identified object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
nominalRatio
Nominal ratio between the primary and secondary current; i.e. 100:5.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
PowerSystemResources
All power system resources with this datasheet information.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
primaryFlsRating
Full load secondary (FLS) rating for primary winding.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
primaryRatio
Ratio for the primary winding tap changer.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
ProductAssetModel
Product asset model which conforms to this catalog asset type.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
PropertiesCIMDataObject
The single CIM data object in the appropriate dataset context.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
ratedCurrent
Rated current on the primary side.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
secondaryFlsRating
Full load secondary (FLS) rating for secondary winding.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
secondaryRatio
Ratio for the secondary winding tap changer.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
TargetingCIMDataObject
Data objects registered.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
tertiaryFlsRating
Full load secondary (FLS) rating for tertiary winding.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
tertiaryRatio
Ratio for the tertiary winding tap changer.
URI |
|
---|---|
Cardinality |
0..1 |
Type |