HydroPowerPlant
A hydro power station which can generate or pump. When generating, the generator turbines receive water from an upper reservoir. When pumping, the pumps receive their water from a lower reservoir.
Type |
Class |
---|---|
URI |
|
CIM standard (perspective) |
IEC61970 (Grid) |
Slots
Name | Cardinality | Type | Description |
---|---|---|---|
1 |
Generators are supplied water from or pumps discharge water to an upstream reservoir. |
||
1 |
Dataset containing the data objects. |
||
0..1 |
Generators discharge water to or pumps are supplied water from a downstream reservoir. |
||
0..1 |
Water travel delay from tailbay to next downstream hydro power station. |
||
0..1 |
The hydro plant's generating rating active power for rated head conditions. The attribute shall be a positive value. |
||
0..1 |
The type of hydro power plant water storage. |
||
0..1 |
Type and configuration of hydro plant penstock(s). |
||
0..1 |
Total plant discharge capacity. |
||
0..1 |
The plant's rated gross head. The attribute shall be a positive value. |
||
0..1 |
The hydro plant's pumping rating active power for rated head conditions. The attribute shall be a positive value. |
||
0..1 |
A code describing the type (or absence) of surge tank that is associated with the hydro power plant. |
||
0..1 |
The level at which the surge tank spills. |
||
0..* |
The hydro generating unit belongs to a hydro power plant. |
||
0..* |
The hydro pump may be a member of a pumped storage plant or a pump for distributing water. |
||
0..1 |
Datasheet information for this power system resource. |
||
0..1 |
Location of this power system resource. |
||
0..1 |
Custom classification for this power system resource. |
||
0..1 |
The single CIM data object in the appropriate dataset context. |
||
0..1 |
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time. |
||
0..1 |
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. |
||
0..1 |
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. |
||
0..1 |
The name is any free human readable and possibly non unique text naming the object. |
||
0..* |
All assets represented by this power system resource. For example, multiple conductor assets are electrically modelled as a single AC line segment. |
||
0..* |
All clearances applicable to this power system resource. |
||
0..* |
All configuration events created for this Power System resource. |
||
0..* |
The controller outputs used to actually govern a regulating device, e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator. |
||
0..* |
The diagram objects that are associated with the domain object. |
||
0..* |
The generic action that is performed on the power system resource |
||
0..* |
The measurements associated with this power system resource. |
||
0..* |
All names of this identified object. |
||
0..* |
The operating shares of this power system resource. |
||
0..* |
All operational tags placed on this power system resource. |
||
0..* |
All events associated with this power system resource. |
||
0..* |
Reporting groups to which this power system resource belongs. |
||
0..* |
Data objects registered. |
||
0..* |
The verification action that is performed on the power system resource |
aliasName
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
AssetDatasheet
Datasheet information for this power system resource.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Assets
All assets represented by this power system resource. For example, multiple conductor assets are electrically modelled as a single AC line segment.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
Clearances
All clearances applicable to this power system resource.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
ConfigurationEvent
All configuration events created for this Power System resource.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
Controls
The controller outputs used to actually govern a regulating device, e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
DiagramObjects
The diagram objects that are associated with the domain object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
dischargeTravelDelay
Water travel delay from tailbay to next downstream hydro power station.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
GenericAction
The generic action that is performed on the power system resource
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
genRatedP
The hydro plant's generating rating active power for rated head conditions. The attribute shall be a positive value.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
GenSourcePumpDischargeReservoir
Generators are supplied water from or pumps discharge water to an upstream reservoir.
URI |
|
---|---|
Cardinality |
1 |
Type |
HydroGeneratingUnits
The hydro generating unit belongs to a hydro power plant.
URI |
|
---|---|
Cardinality |
0..* |
Type |
hydroPlantStorageType
The type of hydro power plant water storage.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
HydroPumps
The hydro pump may be a member of a pumped storage plant or a pump for distributing water.
URI |
|
---|---|
Cardinality |
0..* |
Type |
InstanceSet
Dataset containing the data objects.
URI |
|
---|---|
Cardinality |
1 |
Type |
|
Inherited from |
Location
Location of this power system resource.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Measurements
The measurements associated with this power system resource.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
mRID
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
name
The name is any free human readable and possibly non unique text naming the object.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Names
All names of this identified object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
OperatingShare
The operating shares of this power system resource.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
OperationalTags
All operational tags placed on this power system resource.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
penstockType
Type and configuration of hydro plant penstock(s).
URI |
|
---|---|
Cardinality |
0..1 |
Type |
plantDischargeCapacity
Total plant discharge capacity.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
plantRatedHead
The plant's rated gross head. The attribute shall be a positive value.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
PropertiesCIMDataObject
The single CIM data object in the appropriate dataset context.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
PSREvents
All events associated with this power system resource.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
PSRType
Custom classification for this power system resource.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
pumpRatedP
The hydro plant's pumping rating active power for rated head conditions. The attribute shall be a positive value.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
ReportingGroup
Reporting groups to which this power system resource belongs.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
Reservoir
Generators discharge water to or pumps are supplied water from a downstream reservoir.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
surgeTankCode
A code describing the type (or absence) of surge tank that is associated with the hydro power plant.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
surgeTankCrestLevel
The level at which the surge tank spills.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
TargetingCIMDataObject
Data objects registered.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |