CableInfo
Cable data.
Type |
Class |
---|---|
URI |
|
CIM standard (perspective) |
IEC61968 (Enterprise) |
Slots
Name | Cardinality | Type | Description |
---|---|---|---|
1 |
Dataset containing the data objects. |
||
0..1 |
Kind of construction of this cable. |
||
0..1 |
Diameter over the core, including any semi-con screen; should be the insulating layer's inside diameter. |
||
0..1 |
Diameter over the insulating layer, excluding outer screen. |
||
0..1 |
Diameter over the outermost jacketing layer. |
||
0..1 |
Diameter over the outer screen; should be the shield's inside diameter. |
||
0..1 |
True if wire strands are extruded in a way to fill the voids in the cable. |
||
0..1 |
Maximum nominal design operating temperature. |
||
0..1 |
Kind of outer jacket of this cable. |
||
0..1 |
True if sheath / shield is used as a neutral (i.e., bonded). |
||
0..1 |
Material of the shield. |
||
0..1 |
Asset information (nameplate) for this catalog asset type. |
||
0..1 |
Product asset model which conforms to this catalog asset type. |
||
0..1 |
The single CIM data object in the appropriate dataset context. |
||
0..1 |
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time. |
||
0..1 |
(if there is a different core material) Radius of the central core. |
||
0..1 |
(if used) Number of strands in the steel core. |
||
0..1 |
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. |
||
0..1 |
Geometric mean radius. If we replace the conductor by a thin walled tube of radius GMR, then its reactance is identical to the reactance of the actual conductor. |
||
0..1 |
True if conductor is insulated. |
||
0..1 |
(if insulated conductor) Material used for insulation. |
||
0..1 |
(if insulated conductor) Thickness of the insulation. |
||
0..1 |
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. |
||
0..1 |
Conductor material. |
||
0..1 |
The name is any free human readable and possibly non unique text naming the object. |
||
0..1 |
AC resistance per unit length of the conductor at 25 °C. |
||
0..1 |
AC resistance per unit length of the conductor at 50 °C. |
||
0..1 |
AC resistance per unit length of the conductor at 75 °C. |
||
0..1 |
DC resistance per unit length of the conductor at 20 °C. |
||
0..1 |
Outside radius of the wire. |
||
0..1 |
Current carrying capacity of the wire under stated thermal conditions. |
||
0..1 |
Describes the wire gauge or cross section (e.g., 4/0, #2, 336.5). |
||
0..1 |
Number of strands in the conductor. |
||
0..* |
AC line segment phase information associated with this wire information. |
||
0..* |
All assets described by this data. |
||
0..* |
The diagram objects that are associated with the domain object. |
||
0..* |
All names of this identified object. |
||
0..* |
All power system resources with this datasheet information. |
||
0..* |
Data objects registered. |
||
0..* |
Wire phase information associated with this wire information. |
ACLineSegmentPhase
AC line segment phase information associated with this wire information.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
aliasName
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Assets
All assets described by this data.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
CatalogAssetType
Asset information (nameplate) for this catalog asset type.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
constructionKind
Kind of construction of this cable.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
coreRadius
(if there is a different core material) Radius of the central core.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
coreStrandCount
(if used) Number of strands in the steel core.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
DiagramObjects
The diagram objects that are associated with the domain object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
diameterOverCore
Diameter over the core, including any semi-con screen; should be the insulating layer's inside diameter.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
diameterOverInsulation
Diameter over the insulating layer, excluding outer screen.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
diameterOverJacket
Diameter over the outermost jacketing layer.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
diameterOverScreen
Diameter over the outer screen; should be the shield's inside diameter.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
gmr
Geometric mean radius. If we replace the conductor by a thin walled tube of radius GMR, then its reactance is identical to the reactance of the actual conductor.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
InstanceSet
Dataset containing the data objects.
URI |
|
---|---|
Cardinality |
1 |
Type |
|
Inherited from |
insulated
True if conductor is insulated.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
insulationMaterial
(if insulated conductor) Material used for insulation.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
insulationThickness
(if insulated conductor) Thickness of the insulation.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
isStrandFill
True if wire strands are extruded in a way to fill the voids in the cable.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
mRID
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
name
The name is any free human readable and possibly non unique text naming the object.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Names
All names of this identified object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
nominalTemperature
Maximum nominal design operating temperature.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
outerJacketKind
Kind of outer jacket of this cable.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
PowerSystemResources
All power system resources with this datasheet information.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
ProductAssetModel
Product asset model which conforms to this catalog asset type.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
PropertiesCIMDataObject
The single CIM data object in the appropriate dataset context.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
rAC25
AC resistance per unit length of the conductor at 25 °C.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
rAC50
AC resistance per unit length of the conductor at 50 °C.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
rAC75
AC resistance per unit length of the conductor at 75 °C.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
ratedCurrent
Current carrying capacity of the wire under stated thermal conditions.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
rDC20
DC resistance per unit length of the conductor at 20 °C.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
sheathAsNeutral
True if sheath / shield is used as a neutral (i.e., bonded).
URI |
|
---|---|
Cardinality |
0..1 |
Type |
sizeDescription
Describes the wire gauge or cross section (e.g., 4/0, #2, 336.5).
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
strandCount
Number of strands in the conductor.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
TargetingCIMDataObject
Data objects registered.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |