ReactiveCapabilityCurve
Reactive power rating envelope versus the synchronous machine's active power, in both the generating and motoring modes. For each active power value there is a corresponding high and low reactive power limit value. Typically there will be a separate curve for each coolant condition, such as hydrogen pressure. The Y1 axis values represent reactive minimum and the Y2 axis values represent reactive maximum.
Type |
Class |
---|---|
URI |
|
CIM standard (perspective) |
IEC61970 (Grid) |
Slots
Name | Cardinality | Type | Description |
---|---|---|---|
1..* |
Synchronous machines using this curve as default. |
||
1..* |
Synchronous machines using this curve. |
||
1 |
Dataset containing the data objects. |
||
0..1 |
The machine's coolant temperature (e.g., ambient air or stator circulating water). |
||
0..1 |
The hydrogen coolant pressure. |
||
0..* |
The equivalent injection using this reactive capability curve. |
||
0..1 |
The single CIM data object in the appropriate dataset context. |
||
0..1 |
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time. |
||
0..1 |
The style or shape of the curve. |
||
0..1 |
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. |
||
0..1 |
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. |
||
0..1 |
The name is any free human readable and possibly non unique text naming the object. |
||
0..1 |
Multiplier for X-axis. |
||
0..1 |
The X-axis units of measure. |
||
0..1 |
Multiplier for Y1-axis. |
||
0..1 |
The Y1-axis units of measure. |
||
0..1 |
Multiplier for Y2-axis. |
||
0..1 |
The Y2-axis units of measure. |
||
0..1 |
Multiplier for Y3-axis. |
||
0..1 |
The Y3-axis units of measure. |
||
0..* |
The point data values that define this curve. |
||
0..* |
The diagram objects that are associated with the domain object. |
||
0..* |
All names of this identified object. |
||
0..* |
Data objects registered. |
aliasName
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
coolantTemperature
The machine's coolant temperature (e.g., ambient air or stator circulating water).
URI |
|
---|---|
Cardinality |
0..1 |
Type |
CurveDatas
The point data values that define this curve.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
curveStyle
The style or shape of the curve.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
DiagramObjects
The diagram objects that are associated with the domain object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
EquivalentInjection
The equivalent injection using this reactive capability curve.
URI |
|
---|---|
Cardinality |
0..* |
Type |
hydrogenPressure
The hydrogen coolant pressure.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
InitiallyUsedBySynchronousMachines
Synchronous machines using this curve as default.
URI |
|
---|---|
Cardinality |
1..* |
Type |
InstanceSet
Dataset containing the data objects.
URI |
|
---|---|
Cardinality |
1 |
Type |
|
Inherited from |
mRID
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
name
The name is any free human readable and possibly non unique text naming the object.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Names
All names of this identified object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
PropertiesCIMDataObject
The single CIM data object in the appropriate dataset context.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
SynchronousMachines
Synchronous machines using this curve.
URI |
|
---|---|
Cardinality |
1..* |
Type |
TargetingCIMDataObject
Data objects registered.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
y1Multiplier
Multiplier for Y1-axis.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
y2Multiplier
Multiplier for Y2-axis.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
y3Multiplier
Multiplier for Y3-axis.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |