MeterReading

Set of values obtained from the meter.

Type

Class

URI

cim:MeterReading

CIM standard (perspective)

IEC61968 (Enterprise)

Class hierarchy

Slots

Associated classes
Figure 1. Associated classes
Name Cardinality Type Description

InstanceSet

1

InstanceSet

Dataset containing the data objects.

CustomerAgreement

0..1

CustomerAgreement

(could be deprecated in the future) Customer agreement for this meter reading.

Meter

0..1

Meter

Meter providing this reading.

UsagePoint

0..1

UsagePoint

Usage point from which this meter reading (set of values) has been obtained.

isCoincidentTrigger

0..1

boolean

If true, this meter reading is the meter reading for which other coincident meter readings are requested or provided.

valuesInterval

0..1

DateTimeInterval

Date and time interval of the data items contained within this meter reading.

EndDeviceEvents

0..*

EndDeviceEvent

All end device events associated with this set of measured values.

IntervalBlocks

0..*

IntervalBlock

All interval blocks contained in this meter reading.

Readings

0..*

Reading

All reading values contained within this meter reading.

PropertiesCIMDataObject

0..1

ChangeSetMember

The single CIM data object in the appropriate dataset context.

aliasName

0..1

string

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

description

0..1

string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

mRID

0..1

string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

name

0..1

string

The name is any free human readable and possibly non unique text naming the object.

DiagramObjects

0..*

DiagramObject

The diagram objects that are associated with the domain object.

Names

0..*

Name

All names of this identified object.

TargetingCIMDataObject

0..*

ChangeSetMember

Data objects registered.


aliasName

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

URI

cim:IdentifiedObject.aliasName

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

CustomerAgreement

(could be deprecated in the future) Customer agreement for this meter reading.

URI

cim:MeterReading.CustomerAgreement

Cardinality

0..1

Type

CustomerAgreement

description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

URI

cim:IdentifiedObject.description

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

DiagramObjects

The diagram objects that are associated with the domain object.

URI

cim:IdentifiedObject.DiagramObjects

Cardinality

0..*

Type

DiagramObject

Inherited from

IdentifiedObject

EndDeviceEvents

All end device events associated with this set of measured values.

URI

cim:MeterReading.EndDeviceEvents

Cardinality

0..*

Type

EndDeviceEvent

InstanceSet

Dataset containing the data objects.

URI

cim:IdentifiedObject.InstanceSet

Cardinality

1

Type

InstanceSet

Inherited from

IdentifiedObject

IntervalBlocks

All interval blocks contained in this meter reading.

URI

cim:MeterReading.IntervalBlocks

Cardinality

0..*

Type

IntervalBlock

isCoincidentTrigger

If true, this meter reading is the meter reading for which other coincident meter readings are requested or provided.

URI

cim:MeterReading.isCoincidentTrigger

Cardinality

0..1

Type

boolean

Meter

Meter providing this reading.

URI

cim:MeterReading.Meter

Cardinality

0..1

Type

Meter

mRID

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

URI

cim:IdentifiedObject.mRID

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

name

The name is any free human readable and possibly non unique text naming the object.

URI

cim:IdentifiedObject.name

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

Names

All names of this identified object.

URI

cim:IdentifiedObject.Names

Cardinality

0..*

Type

Name

Inherited from

IdentifiedObject

PropertiesCIMDataObject

The single CIM data object in the appropriate dataset context.

URI

cim:IdentifiedObject.PropertiesCIMDataObject

Cardinality

0..1

Type

ChangeSetMember

Inherited from

IdentifiedObject

Readings

All reading values contained within this meter reading.

URI

cim:MeterReading.Readings

Cardinality

0..*

Type

Reading

TargetingCIMDataObject

Data objects registered.

URI

cim:IdentifiedObject.TargetingCIMDataObject

Cardinality

0..*

Type

ChangeSetMember

Inherited from

IdentifiedObject

UsagePoint

Usage point from which this meter reading (set of values) has been obtained.

URI

cim:MeterReading.UsagePoint

Cardinality

0..1

Type

UsagePoint

valuesInterval

Date and time interval of the data items contained within this meter reading.

URI

cim:MeterReading.valuesInterval

Cardinality

0..1

Type

DateTimeInterval