WindPitchContPowerIEC

Pitch control power model. Reference: IEC 61400-27-1:2015, 5.6.5.1.

Type

Class

URI

cim:WindPitchContPowerIEC

CIM standard (perspective)

IEC61970 (Grid)

Class hierarchy

Slots

Associated classes
Figure 1. Associated classes
Name Cardinality Type Description

WindDynamicsLookupTable

1..*

WindDynamicsLookupTable

The wind dynamics lookup table associated with this pitch control power model.

InstanceSet

1

InstanceSet

Dataset containing the data objects.

WindGenTurbineType1bIEC

0..1

WindGenTurbineType1bIEC

Wind turbine type 1B model with which this pitch control power model is associated.

WindGenTurbineType2IEC

0..1

WindGenTurbineType2IEC

Wind turbine type 2 model with which this pitch control power model is associated.

dpmax

0..1

PU

Rate limit for increasing power (dpmax) (> WindPitchContPowerIEC.dpmin). It is a type-dependent parameter.

dpmin

0..1

PU

Rate limit for decreasing power (dpmin) (< WindPitchContPowerIEC.dpmax). It is a type-dependent parameter.

pmin

0..1

PU

Minimum power setting (pmin). It is a type-dependent parameter.

pset

0..1

PU

If pinit < pset then power will be ramped down to pmin. It is (pset) in the IEC 61400-27-1:2015. It is a type-dependent parameter.

t1

0..1

Seconds

Lag time constant (T1) (>= 0). It is a type-dependent parameter.

tr

0..1

Seconds

Voltage measurement time constant (Tr) (>= 0). It is a type-dependent parameter.

uuvrt

0..1

PU

Dip detection threshold (uUVRT). It is a type-dependent parameter.

PropertiesCIMDataObject

0..1

ChangeSetMember

The single CIM data object in the appropriate dataset context.

aliasName

0..1

string

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

description

0..1

string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

mRID

0..1

string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

name

0..1

string

The name is any free human readable and possibly non unique text naming the object.

DiagramObjects

0..*

DiagramObject

The diagram objects that are associated with the domain object.

Names

0..*

Name

All names of this identified object.

TargetingCIMDataObject

0..*

ChangeSetMember

Data objects registered.


aliasName

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

URI

cim:IdentifiedObject.aliasName

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

URI

cim:IdentifiedObject.description

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

DiagramObjects

The diagram objects that are associated with the domain object.

URI

cim:IdentifiedObject.DiagramObjects

Cardinality

0..*

Type

DiagramObject

Inherited from

IdentifiedObject

dpmax

Rate limit for increasing power (dpmax) (> WindPitchContPowerIEC.dpmin). It is a type-dependent parameter.

URI

cim:WindPitchContPowerIEC.dpmax

Cardinality

0..1

Type

PU

dpmin

Rate limit for decreasing power (dpmin) (< WindPitchContPowerIEC.dpmax). It is a type-dependent parameter.

URI

cim:WindPitchContPowerIEC.dpmin

Cardinality

0..1

Type

PU

InstanceSet

Dataset containing the data objects.

URI

cim:IdentifiedObject.InstanceSet

Cardinality

1

Type

InstanceSet

Inherited from

IdentifiedObject

mRID

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

URI

cim:IdentifiedObject.mRID

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

name

The name is any free human readable and possibly non unique text naming the object.

URI

cim:IdentifiedObject.name

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

Names

All names of this identified object.

URI

cim:IdentifiedObject.Names

Cardinality

0..*

Type

Name

Inherited from

IdentifiedObject

pmin

Minimum power setting (pmin). It is a type-dependent parameter.

URI

cim:WindPitchContPowerIEC.pmin

Cardinality

0..1

Type

PU

PropertiesCIMDataObject

The single CIM data object in the appropriate dataset context.

URI

cim:IdentifiedObject.PropertiesCIMDataObject

Cardinality

0..1

Type

ChangeSetMember

Inherited from

IdentifiedObject

pset

If pinit < pset then power will be ramped down to pmin. It is (pset) in the IEC 61400-27-1:2015. It is a type-dependent parameter.

URI

cim:WindPitchContPowerIEC.pset

Cardinality

0..1

Type

PU

t1

Lag time constant (T1) (>= 0). It is a type-dependent parameter.

URI

cim:WindPitchContPowerIEC.t1

Cardinality

0..1

Type

Seconds

TargetingCIMDataObject

Data objects registered.

URI

cim:IdentifiedObject.TargetingCIMDataObject

Cardinality

0..*

Type

ChangeSetMember

Inherited from

IdentifiedObject

tr

Voltage measurement time constant (Tr) (>= 0). It is a type-dependent parameter.

URI

cim:WindPitchContPowerIEC.tr

Cardinality

0..1

Type

Seconds

uuvrt

Dip detection threshold (uUVRT). It is a type-dependent parameter.

URI

cim:WindPitchContPowerIEC.uuvrt

Cardinality

0..1

Type

PU

WindDynamicsLookupTable

The wind dynamics lookup table associated with this pitch control power model.

URI

cim:WindPitchContPowerIEC.WindDynamicsLookupTable

Cardinality

1..*

Type

WindDynamicsLookupTable

WindGenTurbineType1bIEC

Wind turbine type 1B model with which this pitch control power model is associated.

URI

cim:WindPitchContPowerIEC.WindGenTurbineType1bIEC

Cardinality

0..1

Type

WindGenTurbineType1bIEC

WindGenTurbineType2IEC

Wind turbine type 2 model with which this pitch control power model is associated.

URI

cim:WindPitchContPowerIEC.WindGenTurbineType2IEC

Cardinality

0..1

Type

WindGenTurbineType2IEC