CombinedCycleConfiguration
Configuration options for combined cycle units. For example, a Combined Cycle with (CT1, CT2, ST1) will have (CT1, ST1) and (CT2, ST1) configurations as part of(1CT + 1STlogicalconfiguration).
Type |
Class |
---|---|
URI |
|
CIM standard (perspective) |
IEC62325 (Market) |
Slots
Name | Cardinality | Type | Description |
---|---|---|---|
1 |
n/a |
||
1 |
Dataset containing the data objects. |
||
0..1 |
n/a |
||
0..1 |
Whether Combined Cycle Plant can be shut-down in this Configuration? |
||
0..1 |
Whether Combined Cycle Plant can be started in this Logical Configuration? |
||
0..1 |
Whether this CombinedCycleConfiguration is the primary configuration in the associated Logical configuration? |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..1 |
Indication that this resource is associated with an Adjacent Control Area. |
||
0..1 |
Indication that the resource participates in the optimization process by default. |
||
0..1 |
n/a |
||
0..1 |
An AggregateNode may be associated with up to many RegisteredResources. |
||
0..1 |
Datasheet information for this power system resource. |
||
0..1 |
n/a |
||
0..1 |
Indication that this resource is associated with an Embedded Control area. |
||
0..1 |
n/a |
||
0..1 |
n/a |
||
0..1 |
n/a |
||
0..1 |
LMPM flag: indicates whether the resource is subject to the LMPM test (Yes/No). |
||
0..1 |
n/a |
||
0..1 |
Location of this power system resource. |
||
0..1 |
n/a |
||
0..1 |
n/a |
||
0..1 |
n/a |
||
0..1 |
Custom classification for this power system resource. |
||
0..1 |
A registered resource injects power at one or more connectivity nodes related to a pnode |
||
0..1 |
The single CIM data object in the appropriate dataset context. |
||
0..1 |
Reliability must not run (RMNR) flag: indicated whether the RMR unit is set as an RMNR in the current market |
||
0..1 |
Reliability must run (RMR) flag: indicates whether the unit is RMR; Indicates whether the unit is RMR: N' - not an RMR unit '1' - RMR Condition 1 unit '2' - RMR Condition 2 unit |
||
0..1 |
n/a |
||
0..1 |
Indicates the RMR Manual pre-determination status [Y/N] |
||
0..1 |
n/a |
||
0..1 |
n/a |
||
0..1 |
n/a |
||
0..1 |
n/a |
||
0..1 |
Reliability must take (RMT) flag (Yes/No): indicates whether the unit is RMT |
||
0..1 |
n/a |
||
0..1 |
n/a |
||
0..1 |
SMPM flag: indicates whether the resource is subject to the SMPM test (Yes/No). |
||
0..1 |
n/a |
||
0..1 |
n/a |
||
0..1 |
n/a |
||
0..1 |
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time. |
||
0..1 |
The ratio of actual energy produced by resource divided by the maximum potential energy if the resource is fully utilized. As an example, wind farms. |
||
0..1 |
Cold start time. |
||
0..1 |
Combined Cycle operating mode. |
||
0..1 |
Resource Commercial Operation Date. |
||
0..1 |
n/a |
||
0..1 |
Constrained Output Generator (COG) Indicator (Yes/No), per Generating Resource |
||
0..1 |
Contingent operating reserve availiability (Yes/No). Resource is availiable to participate with capacity in contingency dispatch. |
||
0..1 |
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. |
||
0..1 |
Dispatchable: indicates whether the resource is dispatchable. This implies that the resource intends to submit Energy bids/offers or Ancillary Services bids/offers, or self-provided schedules. |
||
0..1 |
Response rate in MW per minute for ramping energy down. |
||
0..1 |
Response rate in MW per minute for ramping energy up. |
||
0..1 |
Some long-start up time units may need to receive start up instruction before DA market results are available. Long-Start resources may be either physical resources within the control with start-up times greater than 18 hours or the long-start contractual inter-tie commitment that shall be completed by 6 am one-day ahead. Therefore, there is a need for a process to determine the commitment of such resources before the DA market. |
||
0..1 |
Flexible offer flag (Y/N). |
||
0..1 |
Values: Natural Gas Based Resource, Non Natural Gas Based Resource "NG" - Natural-Gas-Based Resource - a Resource that is powered by Natural Gas "NNG" - Non-Natural-Gas-Based Resource - a Resouce that is powered by some other fuel than Natural Gas |
||
0..1 |
High limit for secondary (AGC) control |
||
0..1 |
Hot-to-intermediate time (Seasonal) |
||
0..1 |
Hot start time. |
||
0..1 |
Indicates need to dispatch before the start of the operating hour. Only relevant in Real-Time Market. Applies to generation, intertie and participating load resource. Value (Y/N). |
||
0..1 |
Intermediate-to-cold time (Seasonal) |
||
0..1 |
Intermediate start time. |
||
0..1 |
A flag to indicate if a resource is an aggregated resource. |
||
0..1 |
Indication of the last time this item was modified/versioned. |
||
0..1 |
Certifies resources for use in MSS Load Following Down |
||
0..1 |
Certifies resources for use in MSS Load Following Up |
||
0..1 |
Low limit for secondary (AGC) control |
||
0..1 |
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. |
||
0..1 |
Market Participation flag: indicates whether the resource participate in the market. |
||
0..1 |
Maximum base self schedule quantity. |
||
0..1 |
Maximum Dependable Capacity (MNDC). Maximun Net Dependable Capacity is used in association with an RMR contract. |
||
0..1 |
The registered maximum Minimum Load Cost of a Generating Resource registered with a Cost Basis of "Bid Cost". |
||
0..1 |
Maximum on time after start up. |
||
0..1 |
max pumping level of a hydro pump unit |
||
0..1 |
Maximum time this device can be shut down. |
||
0..1 |
maximum start ups per day |
||
0..1 |
Maximum weekly Energy (Seasonal) |
||
0..1 |
Maximum weekly starts (seasonal parameter) |
||
0..1 |
Maximum allowable spinning reserve. Spinning reserve will never be considered greater than this value regardless of the current operating point. |
||
0..1 |
This is the maximum operating MW limit the dispatcher can enter for this unit |
||
0..1 |
Minimum number of consecutive hours a resource shall be dispatched if bid is accepted. |
||
0..1 |
minimum load cost. Value is (currency/hr) |
||
0..1 |
Minimum off time after shut down. |
||
0..1 |
Minimum on time after start up. |
||
0..1 |
The cost basis for minimum load. |
||
0..1 |
The cost for the fuel required to get a Generating Resource to operate at the minimum load level |
||
0..1 |
This is the minimum operating MW limit the dispatcher can enter for this unit. |
||
0..1 |
Must offer flag: indicates whether the unit is subject to the must offer provisions (Y/N). |
||
0..1 |
Flag to indicate that this unit is a resource adequacy resource and must offer. |
||
0..1 |
The name is any free human readable and possibly non unique text naming the object. |
||
0..1 |
MW value stated on the nameplate of the Generator -- the value it potentially could provide. |
||
0..1 |
Flag to indicate that the Resource is not participating in the Market Operations. |
||
0..1 |
The portion of the Operating Cost of a Generating Resource that is not related to fuel cost. |
||
0..1 |
Indication that the registered resource is a Point of Delivery (YES) resource which implies there is a POD Loss Factor. |
||
0..1 |
Price setting flag: indicates whether a resource is capable of setting the Market Clearing Price (Y) for the DA market, and if not, indicates whether the resource shall submit bids for energy at $ 0 (S) or not (N). Initially in the RegisteredGenerator class. It was moved to the RegisteredResource class for the participating load dispatch purpose. |
||
0..1 |
Price setting flag: indicates whether a resource is capable of setting the Market Clearing Price (Y) for the RT market, and if not, indicates whether the resource shall submit bids for energy at $ 0 (S) or not (N). Initially in the RegisteredGenerator class. It was moved to the RegisteredResource class for the participating load dispatch purpose. |
||
0..1 |
The minimum down time for the pump in a pump storage unit. |
||
0..1 |
The minimum up time aspect for the pump in a pump storage unit |
||
0..1 |
The cost to shutdown a pump during the pump aspect of a pump storage unit. |
||
0..1 |
The shutdown time (minutes) of the pump aspect of a pump storage unit. |
||
0..1 |
n/a |
||
0..1 |
Pumping factor for pump storage units, conversion factor between generating and pumping. |
||
0..1 |
Quick start flag (Yes/No). Identifies the registered generator as a quick start unit. A quick start unit is a unit that has the ability to be available for load within a 30 minute period. |
||
0..1 |
Ramp curve type. Identifies the type of curve which may be a fixed, static or dynamic. |
||
0..1 |
Registration Status of resource - Active, Mothballed, Planned, or Decommissioned. |
||
0..1 |
Regulation down response rate in MW per minute |
||
0..1 |
Specifies if the unit is regulating or not regulating or expected to be regulating but is not. |
||
0..1 |
Regulation up response rate in MW per minute. |
||
0..1 |
Indication that this resource participates in the resource adequacy function. |
||
0..1 |
Unit sub type used by Settlements or scheduling application. Application use of the unit sub type may define the necessary types as applicable. |
||
0..1 |
River System the Resource is tied to. |
||
0..1 |
Response rate in MW per minute for spinning reserve. |
||
0..1 |
The cost basis for start up. |
||
0..1 |
Is the Resource Synchronous Condenser capable Resource? |
||
0..1 |
Generating unit type: Combined Cycle, Gas Turbine, Hydro Turbine, Other, Photovoltaic, Hydro Pump-Turbine, Reciprocating Engine, Steam Turbine, Synchronous Condenser, Wind Turbine |
||
0..1 |
Use limit flag: indicates if the use-limited resource is fully scheduled (or has some slack for real-time dispatch) (Y/N) |
||
0..1 |
Provides an indication that this resource is intending to participate in an intermittent resource program. |
||
0..* |
n/a |
||
0..* |
All assets represented by this power system resource. For example, multiple conductor assets are electrically modelled as a single AC line segment. |
||
0..* |
n/a |
||
0..* |
All clearances applicable to this power system resource. |
||
0..* |
n/a |
||
0..* |
All configuration events created for this Power System resource. |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
The controller outputs used to actually govern a regulating device, e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator. |
||
0..* |
The diagram objects that are associated with the domain object. |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
The generic action that is performed on the power system resource |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
The measurements associated with this power system resource. |
||
0..* |
All names of this identified object. |
||
0..* |
The operating shares of this power system resource. |
||
0..* |
All operational tags placed on this power system resource. |
||
0..* |
n/a |
||
0..* |
All events associated with this power system resource. |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
Reporting groups to which this power system resource belongs. |
||
0..* |
RegisteredResources are qualified for resource ancillary service types (which include market product types as well as other types such as BlackStart) by the association to the class ResourceAncillaryServiceQualification. |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
Data objects registered. |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
n/a |
||
0..* |
The verification action that is performed on the power system resource |
ACAFlag
Indication that this resource is associated with an Adjacent Control Area.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
AggregateNode
An AggregateNode may be associated with up to many RegisteredResources.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
aliasName
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
AllocationResultValues
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
AssetDatasheet
Datasheet information for this power system resource.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Assets
All assets represented by this power system resource. For example, multiple conductor assets are electrically modelled as a single AC line segment.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
ASSPOptimizationFlag
Indication that the resource participates in the optimization process by default.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
capacityFactor
The ratio of actual energy produced by resource divided by the maximum potential energy if the resource is fully utilized. As an example, wind farms.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Clearances
All clearances applicable to this power system resource.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
coldStartTime
Cold start time.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
CombinedCycleConfigurationMember
URI |
|
---|---|
Cardinality |
0..* |
Type |
CombinedCycleLogicalConfiguration
URI |
|
---|---|
Cardinality |
0..1 |
Type |
combinedCycleOperatingMode
Combined Cycle operating mode.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
commercialOpDate
Resource Commercial Operation Date.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
commericialOperationDate
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
ConfigurationEvent
All configuration events created for this Power System resource.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
constrainedOutputFlag
Constrained Output Generator (COG) Indicator (Yes/No), per Generating Resource
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
contingencyAvailFlag
Contingent operating reserve availiability (Yes/No). Resource is availiable to participate with capacity in contingency dispatch.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
ContractDistributionFactor
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
ControlAreaDesignation
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
Controls
The controller outputs used to actually govern a regulating device, e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
DiagramObjects
The diagram objects that are associated with the domain object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
dispatchable
Dispatchable: indicates whether the resource is dispatchable. This implies that the resource intends to submit Energy bids/offers or Ancillary Services bids/offers, or self-provided schedules.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
ECAFlag
Indication that this resource is associated with an Embedded Control area.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
energyDownRampRate
Response rate in MW per minute for ramping energy down.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
energyUpRampRate
Response rate in MW per minute for ramping energy up.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
ExpectedEnergyValues
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
ExPostResourceResults
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
extremeLongStart
Some long-start up time units may need to receive start up instruction before DA market results are available. Long-Start resources may be either physical resources within the control with start-up times greater than 18 hours or the long-start contractual inter-tie commitment that shall be completed by 6 am one-day ahead. Therefore, there is a need for a process to determine the commitment of such resources before the DA market.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
flexibleOfferFlag
Flexible offer flag (Y/N).
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
fuelSource
Values: Natural Gas Based Resource, Non Natural Gas Based Resource "NG" - Natural-Gas-Based Resource - a Resource that is powered by Natural Gas "NNG" - Non-Natural-Gas-Based Resource - a Resouce that is powered by some other fuel than Natural Gas
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
GenericAction
The generic action that is performed on the power system resource
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
highControlLimit
High limit for secondary (AGC) control
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
hotIntTime
Hot-to-intermediate time (Seasonal)
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
hotStartTime
Hot start time.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
hourlyPredispatch
Indicates need to dispatch before the start of the operating hour. Only relevant in Real-Time Market. Applies to generation, intertie and participating load resource. Value (Y/N).
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
InstanceSet
Dataset containing the data objects.
URI |
|
---|---|
Cardinality |
1 |
Type |
|
Inherited from |
intColdTime
Intermediate-to-cold time (Seasonal)
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
IntermittentResourceEligibility
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
intStartTime
Intermediate start time.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
isAggregatedRes
A flag to indicate if a resource is an aggregated resource.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
lastModified
Indication of the last time this item was modified/versioned.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
LMPMFlag
LMPM flag: indicates whether the resource is subject to the LMPM test (Yes/No).
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
loadFollowingDownMSS
Certifies resources for use in MSS Load Following Down
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
LoadFollowingOperatorInput
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
loadFollowingUpMSS
Certifies resources for use in MSS Load Following Up
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
LocalReliabilityArea
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Location
Location of this power system resource.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
lowControlLImit
Low limit for secondary (AGC) control
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
MarketObjectStatus
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
marketParticipationFlag
Market Participation flag: indicates whether the resource participate in the market.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
`maxBaseSelfSchedQty `
Maximum base self schedule quantity.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
maxDependableCap
Maximum Dependable Capacity (MNDC). Maximun Net Dependable Capacity is used in association with an RMR contract.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
maximumAllowableSpinningReserve
Maximum allowable spinning reserve. Spinning reserve will never be considered greater than this value regardless of the current operating point.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
maximumOperatingLimit
This is the maximum operating MW limit the dispatcher can enter for this unit
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
maxMinLoadCost
The registered maximum Minimum Load Cost of a Generating Resource registered with a Cost Basis of "Bid Cost".
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
maxOnTime
Maximum on time after start up.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
maxPumpingLevel
max pumping level of a hydro pump unit
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
maxShutdownTime
Maximum time this device can be shut down.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
maxStartUpsPerDay
maximum start ups per day
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
maxWeeklyEnergy
Maximum weekly Energy (Seasonal)
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
maxWeeklyStarts
Maximum weekly starts (seasonal parameter)
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Measurements
The measurements associated with this power system resource.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
minDispatchTime
Minimum number of consecutive hours a resource shall be dispatched if bid is accepted.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
minimumLoadCostBasis
The cost basis for minimum load.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
minimumLoadFuelCost
The cost for the fuel required to get a Generating Resource to operate at the minimum load level
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
minimumOperatingLimit
This is the minimum operating MW limit the dispatcher can enter for this unit.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
minLoadCost
minimum load cost. Value is (currency/hr)
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
minOffTime
Minimum off time after shut down.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
minOnTime
Minimum on time after start up.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
MktConnectivityNode
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
mRID
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
mustOfferFlag
Must offer flag: indicates whether the unit is subject to the must offer provisions (Y/N).
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
mustOfferRA
Flag to indicate that this unit is a resource adequacy resource and must offer.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
name
The name is any free human readable and possibly non unique text naming the object.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
nameplateCapacity
MW value stated on the nameplate of the Generator -- the value it potentially could provide.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Names
All names of this identified object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
nonMarket
Flag to indicate that the Resource is not participating in the Market Operations.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
operatingMaintenanceCost
The portion of the Operating Cost of a Generating Resource that is not related to fuel cost.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
OperatingShare
The operating shares of this power system resource.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
OperationalTags
All operational tags placed on this power system resource.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
Pnode
A registered resource injects power at one or more connectivity nodes related to a pnode
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
pointOfDeliveryFlag
Indication that the registered resource is a Point of Delivery (YES) resource which implies there is a POD Loss Factor.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
priceSetFlagDA
+++Price setting flag: indicates whether a resource is capable of setting the Market Clearing Price (Y) for the DA market, and if not, indicates whether the resource shall submit bids for energy at $ 0 (S) or not (N).
Initially in the RegisteredGenerator class. It was moved to the RegisteredResource class for the participating load dispatch purpose.+
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
priceSetFlagRT
+++Price setting flag: indicates whether a resource is capable of setting the Market Clearing Price (Y) for the RT market, and if not, indicates whether the resource shall submit bids for energy at $ 0 (S) or not (N).
Initially in the RegisteredGenerator class. It was moved to the RegisteredResource class for the participating load dispatch purpose.+
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
primaryConfiguration
Whether this CombinedCycleConfiguration is the primary configuration in the associated Logical configuration?
URI |
|
---|---|
Cardinality |
0..1 |
Type |
PropertiesCIMDataObject
The single CIM data object in the appropriate dataset context.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
PSREvents
All events associated with this power system resource.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
PSRType
Custom classification for this power system resource.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
pumpingFactor
Pumping factor for pump storage units, conversion factor between generating and pumping.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
pumpMinDownTime
The minimum down time for the pump in a pump storage unit.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
pumpMinUpTime
The minimum up time aspect for the pump in a pump storage unit
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
pumpShutdownCost
The cost to shutdown a pump during the pump aspect of a pump storage unit.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
pumpShutdownTime
The shutdown time (minutes) of the pump aspect of a pump storage unit.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
quickStartFlag
Quick start flag (Yes/No). Identifies the registered generator as a quick start unit. A quick start unit is a unit that has the ability to be available for load within a 30 minute period.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
rampCurveType
Ramp curve type. Identifies the type of curve which may be a fixed, static or dynamic.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
registrationStatus
Registration Status of resource - Active, Mothballed, Planned, or Decommissioned.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
regulationDownRampRate
Regulation down response rate in MW per minute
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
regulationFlag
Specifies if the unit is regulating or not regulating or expected to be regulating but is not.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
regulationUpRampRate
Regulation up response rate in MW per minute.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
ReportingGroup
Reporting groups to which this power system resource belongs.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
resourceAdequacyFlag
Indication that this resource participates in the resource adequacy function.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
ResourceAncillaryServiceQualification
RegisteredResources are qualified for resource ancillary service types (which include market product types as well as other types such as BlackStart) by the association to the class ResourceAncillaryServiceQualification.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
ResourceAwardInstruction
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
ResourceCertification
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
ResourceDispatchResults
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
ResourceLoadFollowingInst
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
resourceSubType
Unit sub type used by Settlements or scheduling application. Application use of the unit sub type may define the necessary types as applicable.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
ResourceVerifiableCosts
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
riverSystem
River System the Resource is tied to.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
RMNRFlag
Reliability must not run (RMNR) flag: indicated whether the RMR unit is set as an RMNR in the current market
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
RMRFlag
Reliability must run (RMR) flag: indicates whether the unit is RMR; Indicates whether the unit is RMR: N' - not an RMR unit '1' - RMR Condition 1 unit '2' - RMR Condition 2 unit
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
RMRManualIndicator
Indicates the RMR Manual pre-determination status [Y/N]
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
RMRStartUpCostCurve
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
RMRStartUpEnergyCurve
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
RMRStartUpFuelCurve
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
RMRStartUpTimeCurve
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
RMTFlag
Reliability must take (RMT) flag (Yes/No): indicates whether the unit is RMT
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
RUCAwardInstruction
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
ShutdownFlag
Whether Combined Cycle Plant can be shut-down in this Configuration?
URI |
|
---|---|
Cardinality |
0..1 |
Type |
SMPMFlag
SMPM flag: indicates whether the resource is subject to the SMPM test (Yes/No).
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
spinRampRate
Response rate in MW per minute for spinning reserve.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
startUpCostBasis
The cost basis for start up.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
StartUpCostCurves
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
StartUpEnergyCurve
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
StartupFlag
Whether Combined Cycle Plant can be started in this Logical Configuration?
URI |
|
---|---|
Cardinality |
0..1 |
Type |
SubstitutionResourceList
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
syncCondCapable
Is the Resource Synchronous Condenser capable Resource?
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
TargetingCIMDataObject
Data objects registered.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
UnitInitialConditions
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
unitType
Generating unit type: Combined Cycle, Gas Turbine, Hydro Turbine, Other, Photovoltaic, Hydro Pump-Turbine, Reciprocating Engine, Steam Turbine, Synchronous Condenser, Wind Turbine
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
useLimitFlag
Use limit flag: indicates if the use-limited resource is fully scheduled (or has some slack for real-time dispatch) (Y/N)
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
variableEnergyResource
Provides an indication that this resource is intending to participate in an intermittent resource program.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|