MarketEvaluationPoint

The identification of an entity where energy products are measured or computed.

Type

Class

URI

cim:MarketEvaluationPoint

CIM standard (perspective)

IEC62325 (Market)

Class hierarchy

Slots

Associated classes
Figure 1. Associated classes
Name Cardinality Type Description

InstanceSet

1

InstanceSet

Dataset containing the data objects.

TimeSeries

0..*

TimeSeries

n/a

CustomerAgreement

0..1

CustomerAgreement

Customer agreement regulating this service delivery point.

EnvironmentalMonitoringStation

0..1

EnvironmentalMonitoringStation

n/a

MeterReadSchedule

0..1

MeterReadSchedule

Meter read schedule that applies to the usage point

PropertiesCIMDataObject

0..1

ChangeSetMember

The single CIM data object in the appropriate dataset context.

ServiceCategory

0..1

ServiceCategory

Service category delivered by this usage point.

ServiceLocation

0..1

ServiceLocation

Service location where the service delivered by this usage point is consumed.

ServiceSupplier

0..1

ServiceSupplier

ServiceSupplier (utility) utilising this usage point to deliver a service.

UsagePointLocation

0..1

UsagePointLocation

Location of this usage point.

aliasName

0..1

string

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

amiBillingReady

0..1

AmiBillingReadyKind

Tracks the lifecycle of the metering installation at a usage point with respect to readiness for billing via advanced metering infrastructure reads.

checkBilling

0..1

boolean

True if as a result of an inspection or otherwise, there is a reason to suspect that a previous billing may have been performed with erroneous data. Value should be reset once this potential discrepancy has been resolved.

connectionCategory

0..1

string

A code used to specify the connection category, e.g., low voltage or low pressure, where the usage point is defined.

connectionState

0..1

UsagePointConnectedKind

State of the usage point with respect to connection to the network.

description

0..1

string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

disconnectionMethod

0..1

string

Is an indication of how the usage point is physically connected or disconnected.

estimatedLoad

0..1

CurrentFlow

Estimated load.

grounded

0..1

boolean

True if grounded.

isSdp

0..1

boolean

If true, this usage point is a service delivery point, i.e., a usage point where the ownership of the service changes hands.

isVirtual

0..1

boolean

If true, this usage point is virtual, i.e., no physical location exists in the network where a meter could be located to collect the meter readings. For example, one may define a virtual usage point to serve as an aggregation of usage for all of a company's premises distributed widely across the distribution territory. Otherwise, the usage point is physical, i.e., there is a logical point in the network where a meter could be located to collect meter readings.

mRID

0..1

string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

minimalUsageExpected

0..1

boolean

If true, minimal or zero usage is expected at this usage point for situations such as premises vacancy, logical or physical disconnect. It is used for readings validation and estimation.

name

0..1

string

The name is any free human readable and possibly non unique text naming the object.

nominalServiceVoltage

0..1

Voltage

Nominal service voltage.

outageRegion

0..1

string

Outage region in which this usage point is located.

phaseCode

0..1

PhaseCode

Phase code. Number of wires and specific nominal phases can be deduced from enumeration literal values. For example, ABCN is three-phase, four-wire, s12n (splitSecondary12N) is single-phase, three-wire, and s1n and s2n are single-phase, two-wire.

phaseCount

0..1

integer

Number of potential phases the Usage Point supports, typically 0, 1 or 3.

physicalConnectionCapacity

0..1

DecimalQuantity

Quantitative information about the maximum physical capacity of the connection for the usage point.

ratedCurrent

0..1

CurrentFlow

Current flow that this usage point is configured to deliver.

ratedPower

0..1

ActivePower

Active power that this usage point is configured to deliver.

readCycle

0..1

string

Cycle day on which the meter for this usage point will normally be read. Usually correlated with the billing cycle.

readRoute

0..1

string

Identifier of the route to which this usage point is assigned for purposes of meter reading. Typically used to configure hand held meter reading systems prior to collection of reads.

serviceDeliveryRemark

0..1

string

Remarks about this usage point, for example the reason for it being rated with a non-nominal priority.

servicePriority

0..1

string

Priority of service for this usage point. Note that usage points at the same service location can have different priorities.

ConfigurationEvents

0..*

ConfigurationEvent

All configuration events created for this usage point.

DiagramObjects

0..*

DiagramObject

The diagram objects that are associated with the domain object.

EndDeviceControls

0..*

EndDeviceControl

All end device controls sending commands to this usage point.

EndDeviceEvents

0..*

EndDeviceEvent

All end device events reported for this usage point.

EndDevices

0..*

EndDevice

All end devices at this usage point.

Equipments

0..*

Equipment

All equipment connecting this usage point to the electrical grid.

MeterReadings

0..*

MeterReading

All meter readings obtained from this usage point.

MeterServiceWorkTasks

0..*

MeterWorkTask

All meter service work tasks at this usage point.

MetrologyRequirements

0..*

MetrologyRequirement

All metrology requirements for this usage point.

Names

0..*

Name

All names of this identified object.

Outage

0..*

Outage

All outages at this Usage Point

PlannedOutageNotification

0..*

PlannedOutageNotification

The planned outage notification for the specified Usage Point.

PricingStructures

0..*

PricingStructure

All pricing structures applicable to this service delivery point (with prepayment meter running as a stand-alone device, with no CustomerAgreement or Customer).

Register

0..*

Register

All registers for quantities metered at this Usage Point.

ServiceMultipliers

0..*

ServiceMultiplier

All multipliers applied at this usage point.

TargetingCIMDataObject

0..*

ChangeSetMember

Data objects registered.

UsagePointGroups

0..*

UsagePointGroup

All groups to which this usage point belongs.


aliasName

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

URI

cim:IdentifiedObject.aliasName

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

amiBillingReady

Tracks the lifecycle of the metering installation at a usage point with respect to readiness for billing via advanced metering infrastructure reads.

URI

cim:UsagePoint.amiBillingReady

Cardinality

0..1

Type

AmiBillingReadyKind

Inherited from

UsagePoint

checkBilling

True if as a result of an inspection or otherwise, there is a reason to suspect that a previous billing may have been performed with erroneous data. Value should be reset once this potential discrepancy has been resolved.

URI

cim:UsagePoint.checkBilling

Cardinality

0..1

Type

boolean

Inherited from

UsagePoint

ConfigurationEvents

All configuration events created for this usage point.

URI

cim:UsagePoint.ConfigurationEvents

Cardinality

0..*

Type

ConfigurationEvent

Inherited from

UsagePoint

connectionCategory

A code used to specify the connection category, e.g., low voltage or low pressure, where the usage point is defined.

URI

cim:UsagePoint.connectionCategory

Cardinality

0..1

Type

string

Inherited from

UsagePoint

connectionState

State of the usage point with respect to connection to the network.

URI

cim:UsagePoint.connectionState

Cardinality

0..1

Type

UsagePointConnectedKind

Inherited from

UsagePoint

CustomerAgreement

Customer agreement regulating this service delivery point.

URI

cim:UsagePoint.CustomerAgreement

Cardinality

0..1

Type

CustomerAgreement

Inherited from

UsagePoint

description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

URI

cim:IdentifiedObject.description

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

DiagramObjects

The diagram objects that are associated with the domain object.

URI

cim:IdentifiedObject.DiagramObjects

Cardinality

0..*

Type

DiagramObject

Inherited from

IdentifiedObject

disconnectionMethod

Is an indication of how the usage point is physically connected or disconnected.

URI

cim:UsagePoint.disconnectionMethod

Cardinality

0..1

Type

string

Inherited from

UsagePoint

EndDeviceControls

All end device controls sending commands to this usage point.

URI

cim:UsagePoint.EndDeviceControls

Cardinality

0..*

Type

EndDeviceControl

Inherited from

UsagePoint

EndDeviceEvents

All end device events reported for this usage point.

URI

cim:UsagePoint.EndDeviceEvents

Cardinality

0..*

Type

EndDeviceEvent

Inherited from

UsagePoint

EndDevices

All end devices at this usage point.

URI

cim:UsagePoint.EndDevices

Cardinality

0..*

Type

EndDevice

Inherited from

UsagePoint

EnvironmentalMonitoringStation

URI

cim:UsagePoint.EnvironmentalMonitoringStation

Cardinality

0..1

Type

EnvironmentalMonitoringStation

Inherited from

UsagePoint

Equipments

All equipment connecting this usage point to the electrical grid.

URI

cim:UsagePoint.Equipments

Cardinality

0..*

Type

Equipment

Inherited from

UsagePoint

estimatedLoad

Estimated load.

URI

cim:UsagePoint.estimatedLoad

Cardinality

0..1

Type

CurrentFlow

Inherited from

UsagePoint

grounded

True if grounded.

URI

cim:UsagePoint.grounded

Cardinality

0..1

Type

boolean

Inherited from

UsagePoint

InstanceSet

Dataset containing the data objects.

URI

cim:IdentifiedObject.InstanceSet

Cardinality

1

Type

InstanceSet

Inherited from

IdentifiedObject

isSdp

If true, this usage point is a service delivery point, i.e., a usage point where the ownership of the service changes hands.

URI

cim:UsagePoint.isSdp

Cardinality

0..1

Type

boolean

Inherited from

UsagePoint

isVirtual

If true, this usage point is virtual, i.e., no physical location exists in the network where a meter could be located to collect the meter readings. For example, one may define a virtual usage point to serve as an aggregation of usage for all of a company's premises distributed widely across the distribution territory. Otherwise, the usage point is physical, i.e., there is a logical point in the network where a meter could be located to collect meter readings.

URI

cim:UsagePoint.isVirtual

Cardinality

0..1

Type

boolean

Inherited from

UsagePoint

MeterReadings

All meter readings obtained from this usage point.

URI

cim:UsagePoint.MeterReadings

Cardinality

0..*

Type

MeterReading

Inherited from

UsagePoint

MeterReadSchedule

Meter read schedule that applies to the usage point

URI

cim:UsagePoint.MeterReadSchedule

Cardinality

0..1

Type

MeterReadSchedule

Inherited from

UsagePoint

MeterServiceWorkTasks

All meter service work tasks at this usage point.

URI

cim:UsagePoint.MeterServiceWorkTasks

Cardinality

0..*

Type

MeterWorkTask

Inherited from

UsagePoint

MetrologyRequirements

All metrology requirements for this usage point.

URI

cim:UsagePoint.MetrologyRequirements

Cardinality

0..*

Type

MetrologyRequirement

Inherited from

UsagePoint

minimalUsageExpected

If true, minimal or zero usage is expected at this usage point for situations such as premises vacancy, logical or physical disconnect. It is used for readings validation and estimation.

URI

cim:UsagePoint.minimalUsageExpected

Cardinality

0..1

Type

boolean

Inherited from

UsagePoint

mRID

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

URI

cim:IdentifiedObject.mRID

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

name

The name is any free human readable and possibly non unique text naming the object.

URI

cim:IdentifiedObject.name

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

Names

All names of this identified object.

URI

cim:IdentifiedObject.Names

Cardinality

0..*

Type

Name

Inherited from

IdentifiedObject

nominalServiceVoltage

Nominal service voltage.

URI

cim:UsagePoint.nominalServiceVoltage

Cardinality

0..1

Type

Voltage

Inherited from

UsagePoint

Outage

All outages at this Usage Point

URI

cim:UsagePoint.Outage

Cardinality

0..*

Type

Outage

Inherited from

UsagePoint

outageRegion

Outage region in which this usage point is located.

URI

cim:UsagePoint.outageRegion

Cardinality

0..1

Type

string

Inherited from

UsagePoint

phaseCode

Phase code. Number of wires and specific nominal phases can be deduced from enumeration literal values. For example, ABCN is three-phase, four-wire, s12n (splitSecondary12N) is single-phase, three-wire, and s1n and s2n are single-phase, two-wire.

URI

cim:UsagePoint.phaseCode

Cardinality

0..1

Type

PhaseCode

Inherited from

UsagePoint

phaseCount

Number of potential phases the Usage Point supports, typically 0, 1 or 3.

URI

cim:UsagePoint.phaseCount

Cardinality

0..1

Type

integer

Inherited from

UsagePoint

physicalConnectionCapacity

Quantitative information about the maximum physical capacity of the connection for the usage point.

URI

cim:UsagePoint.physicalConnectionCapacity

Cardinality

0..1

Type

DecimalQuantity

Inherited from

UsagePoint

PlannedOutageNotification

The planned outage notification for the specified Usage Point.

URI

cim:UsagePoint.PlannedOutageNotification

Cardinality

0..*

Type

PlannedOutageNotification

Inherited from

UsagePoint

PricingStructures

All pricing structures applicable to this service delivery point (with prepayment meter running as a stand-alone device, with no CustomerAgreement or Customer).

URI

cim:UsagePoint.PricingStructures

Cardinality

0..*

Type

PricingStructure

Inherited from

UsagePoint

PropertiesCIMDataObject

The single CIM data object in the appropriate dataset context.

URI

cim:IdentifiedObject.PropertiesCIMDataObject

Cardinality

0..1

Type

ChangeSetMember

Inherited from

IdentifiedObject

ratedCurrent

Current flow that this usage point is configured to deliver.

URI

cim:UsagePoint.ratedCurrent

Cardinality

0..1

Type

CurrentFlow

Inherited from

UsagePoint

ratedPower

Active power that this usage point is configured to deliver.

URI

cim:UsagePoint.ratedPower

Cardinality

0..1

Type

ActivePower

Inherited from

UsagePoint

readCycle

Cycle day on which the meter for this usage point will normally be read. Usually correlated with the billing cycle.

URI

cim:UsagePoint.readCycle

Cardinality

0..1

Type

string

Inherited from

UsagePoint

readRoute

Identifier of the route to which this usage point is assigned for purposes of meter reading. Typically used to configure hand held meter reading systems prior to collection of reads.

URI

cim:UsagePoint.readRoute

Cardinality

0..1

Type

string

Inherited from

UsagePoint

Register

All registers for quantities metered at this Usage Point.

URI

cim:UsagePoint.Register

Cardinality

0..*

Type

Register

Inherited from

UsagePoint

ServiceCategory

Service category delivered by this usage point.

URI

cim:UsagePoint.ServiceCategory

Cardinality

0..1

Type

ServiceCategory

Inherited from

UsagePoint

serviceDeliveryRemark

Remarks about this usage point, for example the reason for it being rated with a non-nominal priority.

URI

cim:UsagePoint.serviceDeliveryRemark

Cardinality

0..1

Type

string

Inherited from

UsagePoint

ServiceLocation

Service location where the service delivered by this usage point is consumed.

URI

cim:UsagePoint.ServiceLocation

Cardinality

0..1

Type

ServiceLocation

Inherited from

UsagePoint

ServiceMultipliers

All multipliers applied at this usage point.

URI

cim:UsagePoint.ServiceMultipliers

Cardinality

0..*

Type

ServiceMultiplier

Inherited from

UsagePoint

servicePriority

Priority of service for this usage point. Note that usage points at the same service location can have different priorities.

URI

cim:UsagePoint.servicePriority

Cardinality

0..1

Type

string

Inherited from

UsagePoint

ServiceSupplier

ServiceSupplier (utility) utilising this usage point to deliver a service.

URI

cim:UsagePoint.ServiceSupplier

Cardinality

0..1

Type

ServiceSupplier

Inherited from

UsagePoint

TargetingCIMDataObject

Data objects registered.

URI

cim:IdentifiedObject.TargetingCIMDataObject

Cardinality

0..*

Type

ChangeSetMember

Inherited from

IdentifiedObject

TimeSeries

URI

cim:MarketEvaluationPoint.TimeSeries

Cardinality

0..*

Type

TimeSeries

UsagePointGroups

All groups to which this usage point belongs.

URI

cim:UsagePoint.UsagePointGroups

Cardinality

0..*

Type

UsagePointGroup

Inherited from

UsagePoint

UsagePointLocation

Location of this usage point.

URI

cim:UsagePoint.UsagePointLocation

Cardinality

0..1

Type

UsagePointLocation

Inherited from

UsagePoint