MktControlArea

Market subclass of IEC 61970:ControlArea.

Type

Class

URI

cim:MktControlArea

CIM standard (perspective)

IEC62325 (Market)

Class hierarchy

Slots

Name Type Description Inherited from

ControlAreaSolutionData

0..*
ControlAreaSolutionData

n/a

n/a

ControlAreaGeneratingUnit

0..*
ControlAreaGeneratingUnit

The generating unit specifications for the control area.

ControlArea

EnergyArea

0..1
EnergyArea

The energy area that is forecast from this control area specification.

ControlArea

EnergyGroup

0..*
EnergyGroup

n/a

ControlArea

TieFlow

0..*
TieFlow

The tie flows associated with the control area.

ControlArea

netInterchange

0..1
ActivePower

The specified positive net interchange into the control area, i.e. positive sign means flow into the area.

ControlArea

pTolerance

0..1
ActivePower

Active power net interchange tolerance. The attribute shall be a positive value or zero.

ControlArea

type

0..1
ControlAreaTypeKind

The primary type of control area definition used to determine if this is used for automatic generation control, for planning...

ControlArea

AssetDatasheet

0..1
AssetInfo

Datasheet information for this power system resource.

PowerSystemResource

Assets

0..*
Asset

All assets represented by this power system resource. For example, multiple conductor assets are electrically modelled as a...

PowerSystemResource

Clearances

0..*
ClearanceDocument

All clearances applicable to this power system resource.

PowerSystemResource

ConfigurationEvent

0..*
ConfigurationEvent

All configuration events created for this Power System resource.

PowerSystemResource

Controls

0..*
Control

The controller outputs used to actually govern a regulating device, e.g. the magnetization of a synchronous machine or...

PowerSystemResource

GenericAction

0..*
GenericAction

The generic action that is performed on the power system resource

PowerSystemResource

Location

0..1
Location

Location of this power system resource.

PowerSystemResource

Measurements

0..*
Measurement

The measurements associated with this power system resource.

PowerSystemResource

OperatingShare

0..*
OperatingShare

The operating shares of this power system resource.

PowerSystemResource

OperationalTags

0..*
OperationalTag

All operational tags placed on this power system resource.

PowerSystemResource

PSREvents

0..*
PSREvent

All events associated with this power system resource.

PowerSystemResource

PSRType

0..1
PSRType

Custom classification for this power system resource.

PowerSystemResource

ReportingGroup

0..*
ReportingGroup

Reporting groups to which this power system resource belongs.

PowerSystemResource

VerificationAction

0..*
VerificationAction

The verification action that is performed on the power system resource

PowerSystemResource

DiagramObjects

0..*
DiagramObject

The diagram objects that are associated with the domain object.

IdentifiedObject

InstanceSet

1
InstanceSet

Dataset containing the data objects.

IdentifiedObject

Names

0..*
Name

All names of this identified object.

IdentifiedObject

PropertiesCIMDataObject

0..1
ChangeSetMember

The single CIM data object in the appropriate dataset context.

IdentifiedObject

TargetingCIMDataObject

0..*
ChangeSetMember

Data objects registered.

IdentifiedObject

aliasName

0..1
string

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and...

IdentifiedObject

description

0..1
string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to...

IdentifiedObject

mRID

0..1
string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is...

IdentifiedObject

name

0..1
string

The name is any free human readable and possibly non unique text naming the object.

IdentifiedObject


aliasName

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

URI

cim:IdentifiedObject.aliasName

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

AssetDatasheet

Datasheet information for this power system resource.

URI

cim:PowerSystemResource.AssetDatasheet

Cardinality

0..1

Type

AssetInfo

Inherited from

PowerSystemResource

Assets

All assets represented by this power system resource. For example, multiple conductor assets are electrically modelled as a single AC line segment.

URI

cim:PowerSystemResource.Assets

Cardinality

0..*

Type

Asset

Inherited from

PowerSystemResource

Clearances

All clearances applicable to this power system resource.

URI

cim:PowerSystemResource.Clearances

Cardinality

0..*

Type

ClearanceDocument

Inherited from

PowerSystemResource

ConfigurationEvent

All configuration events created for this Power System resource.

URI

cim:PowerSystemResource.ConfigurationEvent

Cardinality

0..*

Type

ConfigurationEvent

Inherited from

PowerSystemResource

ControlAreaGeneratingUnit

The generating unit specifications for the control area.

URI

cim:ControlArea.ControlAreaGeneratingUnit

Cardinality

0..*

Type

ControlAreaGeneratingUnit

Inherited from

ControlArea

ControlAreaSolutionData

URI

cim:MktControlArea.ControlAreaSolutionData

Cardinality

0..*

Type

ControlAreaSolutionData

Controls

The controller outputs used to actually govern a regulating device, e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator.

URI

cim:PowerSystemResource.Controls

Cardinality

0..*

Type

Control

Inherited from

PowerSystemResource

description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

URI

cim:IdentifiedObject.description

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

DiagramObjects

The diagram objects that are associated with the domain object.

URI

cim:IdentifiedObject.DiagramObjects

Cardinality

0..*

Type

DiagramObject

Inherited from

IdentifiedObject

EnergyArea

The energy area that is forecast from this control area specification.

URI

cim:ControlArea.EnergyArea

Cardinality

0..1

Type

EnergyArea

Inherited from

ControlArea

EnergyGroup

URI

cim:ControlArea.EnergyGroup

Cardinality

0..*

Type

EnergyGroup

Inherited from

ControlArea

GenericAction

The generic action that is performed on the power system resource

URI

cim:PowerSystemResource.GenericAction

Cardinality

0..*

Type

GenericAction

Inherited from

PowerSystemResource

InstanceSet

Dataset containing the data objects.

URI

cim:IdentifiedObject.InstanceSet

Cardinality

1

Type

InstanceSet

Inherited from

IdentifiedObject

Location

Location of this power system resource.

URI

cim:PowerSystemResource.Location

Cardinality

0..1

Type

Location

Inherited from

PowerSystemResource

Measurements

The measurements associated with this power system resource.

URI

cim:PowerSystemResource.Measurements

Cardinality

0..*

Type

Measurement

Inherited from

PowerSystemResource

mRID

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

URI

cim:IdentifiedObject.mRID

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

name

The name is any free human readable and possibly non unique text naming the object.

URI

cim:IdentifiedObject.name

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

Names

All names of this identified object.

URI

cim:IdentifiedObject.Names

Cardinality

0..*

Type

Name

Inherited from

IdentifiedObject

netInterchange

The specified positive net interchange into the control area, i.e. positive sign means flow into the area.

URI

cim:ControlArea.netInterchange

Cardinality

0..1

Type

ActivePower

Inherited from

ControlArea

OperatingShare

The operating shares of this power system resource.

URI

cim:PowerSystemResource.OperatingShare

Cardinality

0..*

Type

OperatingShare

Inherited from

PowerSystemResource

OperationalTags

All operational tags placed on this power system resource.

URI

cim:PowerSystemResource.OperationalTags

Cardinality

0..*

Type

OperationalTag

Inherited from

PowerSystemResource

PropertiesCIMDataObject

The single CIM data object in the appropriate dataset context.

URI

cim:IdentifiedObject.PropertiesCIMDataObject

Cardinality

0..1

Type

ChangeSetMember

Inherited from

IdentifiedObject

PSREvents

All events associated with this power system resource.

URI

cim:PowerSystemResource.PSREvents

Cardinality

0..*

Type

PSREvent

Inherited from

PowerSystemResource

PSRType

Custom classification for this power system resource.

URI

cim:PowerSystemResource.PSRType

Cardinality

0..1

Type

PSRType

Inherited from

PowerSystemResource

pTolerance

Active power net interchange tolerance. The attribute shall be a positive value or zero.

URI

cim:ControlArea.pTolerance

Cardinality

0..1

Type

ActivePower

Inherited from

ControlArea

ReportingGroup

Reporting groups to which this power system resource belongs.

URI

cim:PowerSystemResource.ReportingGroup

Cardinality

0..*

Type

ReportingGroup

Inherited from

PowerSystemResource

TargetingCIMDataObject

Data objects registered.

URI

cim:IdentifiedObject.TargetingCIMDataObject

Cardinality

0..*

Type

ChangeSetMember

Inherited from

IdentifiedObject

TieFlow

The tie flows associated with the control area.

URI

cim:ControlArea.TieFlow

Cardinality

0..*

Type

TieFlow

Inherited from

ControlArea

type

The primary type of control area definition used to determine if this is used for automatic generation control, for planning interchange control, or other purposes. A control area specified with primary type of automatic generation control could still be forecast and used as an interchange area in power flow analysis.

URI

cim:ControlArea.type

Cardinality

0..1

Type

ControlAreaTypeKind

Inherited from

ControlArea

VerificationAction

The verification action that is performed on the power system resource

URI

cim:PowerSystemResource.VerificationAction

Cardinality

0..*

Type

VerificationAction

Inherited from

PowerSystemResource

Used by

Source class Slot name

ControlAreaSolutionData

MktControlArea