NonConformLoad

NonConformLoad represents loads that do not follow a daily load change pattern and whose changes are not correlated with the daily load change pattern.

Type

Class

URI

cim:NonConformLoad

CIM standard (perspective)

IEC61970 (Grid)

Slots

Name Type Description Inherited from

LoadGroup

0..1
NonConformLoadGroup

Group of this ConformLoad.

n/a

EnergyConsumerAction

0..1
EnergyConsumerAction

The energy consumer action that is performed on the energy consumer

EnergyConsumer

EnergyConsumerPhase

0..*
EnergyConsumerPhase

The individual phase models for this energy consumer.

EnergyConsumer

LoadDynamics

0..1
LoadDynamics

Load dynamics model used to describe dynamic behaviour of this energy consumer.

EnergyConsumer

LoadResponse

0..1
LoadResponseCharacteristic

The load response characteristic of this load. If missing, this load is assumed to be constant power.

EnergyConsumer

PowerCutZone

0..1
PowerCutZone

The energy consumer is assigned to this power cut zone.

EnergyConsumer

customerCount

0..1
integer

Number of individual customers represented by this demand.

EnergyConsumer

grounded

0..1
boolean

Used for Yn and Zn connections. True if the neutral is solidly grounded.

EnergyConsumer

p

0..1
ActivePower

Active power of the load. Load sign convention is used, i.e. positive sign means flow out from a node. For voltage...

EnergyConsumer

pfixed

0..1
ActivePower

Active power of the load that is a fixed quantity and does not vary as load group value varies. Load sign convention is...

EnergyConsumer

pfixedPct

0..1
PerCent

Fixed active power as a percentage of load group fixed active power. Used to represent the time-varying components. Load...

EnergyConsumer

phaseConnection

0..1
PhaseShuntConnectionKind

The type of phase connection, such as wye or delta.

EnergyConsumer

q

0..1
ReactivePower

Reactive power of the load. Load sign convention is used, i.e. positive sign means flow out from a node. For voltage...

EnergyConsumer

qfixed

0..1
ReactivePower

Reactive power of the load that is a fixed quantity and does not vary as load group value varies. Load sign convention is...

EnergyConsumer

qfixedPct

0..1
PerCent

Fixed reactive power as a percentage of load group fixed reactive power. Used to represent the time-varying components. ...

EnergyConsumer

EnergyComponent

0..*
EnergyComponent

n/a

EnergyConnection

BaseVoltage

0..1
BaseVoltage

Base voltage of this conducting equipment. Use only when there is no voltage level container used and only one base voltage...

ConductingEquipment

GroundingAction

0..1
GroundAction

Action involving grounding operation on this conducting equipment.

ConductingEquipment

JumpingAction

0..1
JumperAction

Jumper action involving jumping operation on this conducting equipment.

ConductingEquipment

Outage

0..1
Outage

The outage that is isolated by the outage isolation equipment.

ConductingEquipment

ProtectionEquipments

0..*
ProtectionEquipment

Protection equipment used to protect specific conducting equipment.

ConductingEquipment

ProtectiveActionAdjustment

0..*
ProtectiveActionAdjustment

The operating condition to the Conducting Equipment is changed when protective action adjustment is activated. For...

ConductingEquipment

SvStatus

0..*
SvStatus

The status state variable associated with this conducting equipment.

ConductingEquipment

Terminals

0..*
Terminal

Conducting equipment have terminals that may be connected to other conducting equipment terminals via connectivity nodes or...

ConductingEquipment

AdditionalEquipmentContainer

0..*
EquipmentContainer

Additional equipment container beyond the primary equipment container. The equipment is contained in another equipment...

Equipment

ContingencyEquipment

0..*
ContingencyEquipment

The contingency equipments in which this equipment participates.

Equipment

EqiupmentLimitSeriesComponent

0..*
EquipmentLimitSeriesComponent

Equipment limit series calculation component to which this equipment contributes.

Equipment

EquipmentContainer

0..1
EquipmentContainer

Container of this equipment.

Equipment

EquipmentUnavailabilitySchedule

0..*
EquipmentUnavailabilitySchedule

n/a

Equipment

Faults

0..*
Fault

All faults on this equipment.

Equipment

LimitDependencyModel

0..*
LimitDependency

Limit dependencymodels organized under this equipment as a means for organizing the model in a tree view.

Equipment

OperationalLimitSet

0..*
OperationalLimitSet

The operational limit sets associated with this equipment.

Equipment

OperationalRestrictions

0..*
OperationalRestriction

All operational restrictions for this equipment.

Equipment

Outages

0..*
Outage

All outages in which this equipment is involved.

Equipment

PinEquipment

0..*
PinEquipment

n/a

Equipment

ProtectiveActionEquipment

0..*
ProtectiveActionEquipment

Protective action is controlling equipment. This can be direct signals from the control center, or emulation of action done...

Equipment

UsagePoints

0..*
UsagePoint

All usage points connected to the electrical grid through this equipment.

Equipment

WeatherStation

0..*
WeatherStation

n/a

Equipment

aggregate

0..1
boolean

The aggregate flag provides an alternative way of representing an aggregated (equivalent) element. It is applicable in cases...

Equipment

inService

0..1
boolean

Specifies the availability of the equipment. True means the equipment is available for topology processing, which determines...

Equipment

networkAnalysisEnabled

0..1
boolean

The equipment is enabled to participate in network analysis. If unspecified, the value is assumed to be true.

Equipment

normallyInService

0..1
boolean

Specifies the availability of the equipment under normal operating conditions. True means the equipment is available for...

Equipment

AssetDatasheet

0..1
AssetInfo

Datasheet information for this power system resource.

PowerSystemResource

Assets

0..*
Asset

All assets represented by this power system resource. For example, multiple conductor assets are electrically modelled as a...

PowerSystemResource

Clearances

0..*
ClearanceDocument

All clearances applicable to this power system resource.

PowerSystemResource

ConfigurationEvent

0..*
ConfigurationEvent

All configuration events created for this Power System resource.

PowerSystemResource

Controls

0..*
Control

The controller outputs used to actually govern a regulating device, e.g. the magnetization of a synchronous machine or...

PowerSystemResource

GenericAction

0..*
GenericAction

The generic action that is performed on the power system resource

PowerSystemResource

Location

0..1
Location

Location of this power system resource.

PowerSystemResource

Measurements

0..*
Measurement

The measurements associated with this power system resource.

PowerSystemResource

OperatingShare

0..*
OperatingShare

The operating shares of this power system resource.

PowerSystemResource

OperationalTags

0..*
OperationalTag

All operational tags placed on this power system resource.

PowerSystemResource

PSREvents

0..*
PSREvent

All events associated with this power system resource.

PowerSystemResource

PSRType

0..1
PSRType

Custom classification for this power system resource.

PowerSystemResource

ReportingGroup

0..*
ReportingGroup

Reporting groups to which this power system resource belongs.

PowerSystemResource

VerificationAction

0..*
VerificationAction

The verification action that is performed on the power system resource

PowerSystemResource

DiagramObjects

0..*
DiagramObject

The diagram objects that are associated with the domain object.

IdentifiedObject

InstanceSet

1
InstanceSet

Dataset containing the data objects.

IdentifiedObject

Names

0..*
Name

All names of this identified object.

IdentifiedObject

PropertiesCIMDataObject

0..1
ChangeSetMember

The single CIM data object in the appropriate dataset context.

IdentifiedObject

TargetingCIMDataObject

0..*
ChangeSetMember

Data objects registered.

IdentifiedObject

aliasName

0..1
string

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and...

IdentifiedObject

description

0..1
string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to...

IdentifiedObject

mRID

0..1
string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is...

IdentifiedObject

name

0..1
string

The name is any free human readable and possibly non unique text naming the object.

IdentifiedObject


AdditionalEquipmentContainer

Additional equipment container beyond the primary equipment container. The equipment is contained in another equipment container, but also grouped with this equipment container.

URI

cim:Equipment.AdditionalEquipmentContainer

Cardinality

0..*

Type

EquipmentContainer

Inherited from

Equipment

aggregate

The aggregate flag provides an alternative way of representing an aggregated (equivalent) element. It is applicable in cases when the dedicated classes for equivalent equipment do not have all of the attributes necessary to represent the required level of detail. In case the flag is set to “true” the single instance of equipment represents multiple pieces of equipment that have been modelled together as an aggregate equivalent obtained by a network reduction procedure. Examples would be power transformers or synchronous machines operating in parallel modelled as a single aggregate power transformer or aggregate synchronous machine. The attribute is not used for EquivalentBranch, EquivalentShunt and EquivalentInjection.

URI

cim:Equipment.aggregate

Cardinality

0..1

Type

boolean

Inherited from

Equipment

aliasName

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

URI

cim:IdentifiedObject.aliasName

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

AssetDatasheet

Datasheet information for this power system resource.

URI

cim:PowerSystemResource.AssetDatasheet

Cardinality

0..1

Type

AssetInfo

Inherited from

PowerSystemResource

Assets

All assets represented by this power system resource. For example, multiple conductor assets are electrically modelled as a single AC line segment.

URI

cim:PowerSystemResource.Assets

Cardinality

0..*

Type

Asset

Inherited from

PowerSystemResource

BaseVoltage

Base voltage of this conducting equipment. Use only when there is no voltage level container used and only one base voltage applies. For example, not used for transformers.

URI

cim:ConductingEquipment.BaseVoltage

Cardinality

0..1

Type

BaseVoltage

Inherited from

ConductingEquipment

Clearances

All clearances applicable to this power system resource.

URI

cim:PowerSystemResource.Clearances

Cardinality

0..*

Type

ClearanceDocument

Inherited from

PowerSystemResource

ConfigurationEvent

All configuration events created for this Power System resource.

URI

cim:PowerSystemResource.ConfigurationEvent

Cardinality

0..*

Type

ConfigurationEvent

Inherited from

PowerSystemResource

ContingencyEquipment

The contingency equipments in which this equipment participates.

URI

cim:Equipment.ContingencyEquipment

Cardinality

0..*

Type

ContingencyEquipment

Inherited from

Equipment

Controls

The controller outputs used to actually govern a regulating device, e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator.

URI

cim:PowerSystemResource.Controls

Cardinality

0..*

Type

Control

Inherited from

PowerSystemResource

customerCount

Number of individual customers represented by this demand.

URI

cim:EnergyConsumer.customerCount

Cardinality

0..1

Type

integer

Inherited from

EnergyConsumer

description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

URI

cim:IdentifiedObject.description

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

DiagramObjects

The diagram objects that are associated with the domain object.

URI

cim:IdentifiedObject.DiagramObjects

Cardinality

0..*

Type

DiagramObject

Inherited from

IdentifiedObject

EnergyComponent

URI

cim:EnergyConnection.EnergyComponent

Cardinality

0..*

Type

EnergyComponent

Inherited from

EnergyConnection

EnergyConsumerAction

The energy consumer action that is performed on the energy consumer

URI

cim:EnergyConsumer.EnergyConsumerAction

Cardinality

0..1

Type

EnergyConsumerAction

Inherited from

EnergyConsumer

EnergyConsumerPhase

The individual phase models for this energy consumer.

URI

cim:EnergyConsumer.EnergyConsumerPhase

Cardinality

0..*

Type

EnergyConsumerPhase

Inherited from

EnergyConsumer

EqiupmentLimitSeriesComponent

Equipment limit series calculation component to which this equipment contributes.

URI

cim:Equipment.EqiupmentLimitSeriesComponent

Cardinality

0..*

Type

EquipmentLimitSeriesComponent

Inherited from

Equipment

EquipmentContainer

Container of this equipment.

URI

cim:Equipment.EquipmentContainer

Cardinality

0..1

Type

EquipmentContainer

Inherited from

Equipment

EquipmentUnavailabilitySchedule

URI

cim:Equipment.EquipmentUnavailabilitySchedule

Cardinality

0..*

Type

EquipmentUnavailabilitySchedule

Inherited from

Equipment

Faults

All faults on this equipment.

URI

cim:Equipment.Faults

Cardinality

0..*

Type

Fault

Inherited from

Equipment

GenericAction

The generic action that is performed on the power system resource

URI

cim:PowerSystemResource.GenericAction

Cardinality

0..*

Type

GenericAction

Inherited from

PowerSystemResource

grounded

Used for Yn and Zn connections. True if the neutral is solidly grounded.

URI

cim:EnergyConsumer.grounded

Cardinality

0..1

Type

boolean

Inherited from

EnergyConsumer

GroundingAction

Action involving grounding operation on this conducting equipment.

URI

cim:ConductingEquipment.GroundingAction

Cardinality

0..1

Type

GroundAction

Inherited from

ConductingEquipment

inService

Specifies the availability of the equipment. True means the equipment is available for topology processing, which determines if the equipment is energized or not. False means that the equipment is treated by network applications as if it is not in the model.

URI

cim:Equipment.inService

Cardinality

0..1

Type

boolean

Inherited from

Equipment

InstanceSet

Dataset containing the data objects.

URI

cim:IdentifiedObject.InstanceSet

Cardinality

1

Type

InstanceSet

Inherited from

IdentifiedObject

JumpingAction

Jumper action involving jumping operation on this conducting equipment.

URI

cim:ConductingEquipment.JumpingAction

Cardinality

0..1

Type

JumperAction

Inherited from

ConductingEquipment

LimitDependencyModel

Limit dependencymodels organized under this equipment as a means for organizing the model in a tree view.

URI

cim:Equipment.LimitDependencyModel

Cardinality

0..*

Type

LimitDependency

Inherited from

Equipment

LoadDynamics

Load dynamics model used to describe dynamic behaviour of this energy consumer.

URI

cim:EnergyConsumer.LoadDynamics

Cardinality

0..1

Type

LoadDynamics

Inherited from

EnergyConsumer

LoadGroup

Group of this ConformLoad.

URI

cim:NonConformLoad.LoadGroup

Cardinality

0..1

Type

NonConformLoadGroup

LoadResponse

The load response characteristic of this load. If missing, this load is assumed to be constant power.

URI

cim:EnergyConsumer.LoadResponse

Cardinality

0..1

Type

LoadResponseCharacteristic

Inherited from

EnergyConsumer

Location

Location of this power system resource.

URI

cim:PowerSystemResource.Location

Cardinality

0..1

Type

Location

Inherited from

PowerSystemResource

Measurements

The measurements associated with this power system resource.

URI

cim:PowerSystemResource.Measurements

Cardinality

0..*

Type

Measurement

Inherited from

PowerSystemResource

mRID

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

URI

cim:IdentifiedObject.mRID

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

name

The name is any free human readable and possibly non unique text naming the object.

URI

cim:IdentifiedObject.name

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

Names

All names of this identified object.

URI

cim:IdentifiedObject.Names

Cardinality

0..*

Type

Name

Inherited from

IdentifiedObject

networkAnalysisEnabled

The equipment is enabled to participate in network analysis. If unspecified, the value is assumed to be true.

URI

cim:Equipment.networkAnalysisEnabled

Cardinality

0..1

Type

boolean

Inherited from

Equipment

normallyInService

Specifies the availability of the equipment under normal operating conditions. True means the equipment is available for topology processing, which determines if the equipment is energized or not. False means that the equipment is treated by network applications as if it is not in the model.

URI

cim:Equipment.normallyInService

Cardinality

0..1

Type

boolean

Inherited from

Equipment

OperatingShare

The operating shares of this power system resource.

URI

cim:PowerSystemResource.OperatingShare

Cardinality

0..*

Type

OperatingShare

Inherited from

PowerSystemResource

OperationalLimitSet

The operational limit sets associated with this equipment.

URI

cim:Equipment.OperationalLimitSet

Cardinality

0..*

Type

OperationalLimitSet

Inherited from

Equipment

OperationalRestrictions

All operational restrictions for this equipment.

URI

cim:Equipment.OperationalRestrictions

Cardinality

0..*

Type

OperationalRestriction

Inherited from

Equipment

OperationalTags

All operational tags placed on this power system resource.

URI

cim:PowerSystemResource.OperationalTags

Cardinality

0..*

Type

OperationalTag

Inherited from

PowerSystemResource

Outage

The outage that is isolated by the outage isolation equipment.

URI

cim:ConductingEquipment.Outage

Cardinality

0..1

Type

Outage

Inherited from

ConductingEquipment

Outages

All outages in which this equipment is involved.

URI

cim:Equipment.Outages

Cardinality

0..*

Type

Outage

Inherited from

Equipment

p

Active power of the load. Load sign convention is used, i.e. positive sign means flow out from a node. For voltage dependent loads the value is at rated voltage. Starting value for a steady state solution.

URI

cim:EnergyConsumer.p

Cardinality

0..1

Type

ActivePower

Inherited from

EnergyConsumer

pfixed

Active power of the load that is a fixed quantity and does not vary as load group value varies. Load sign convention is used, i.e. positive sign means flow out from a node.

URI

cim:EnergyConsumer.pfixed

Cardinality

0..1

Type

ActivePower

Inherited from

EnergyConsumer

pfixedPct

Fixed active power as a percentage of load group fixed active power. Used to represent the time-varying components. Load sign convention is used, i.e. positive sign means flow out from a node.

URI

cim:EnergyConsumer.pfixedPct

Cardinality

0..1

Type

PerCent

Inherited from

EnergyConsumer

phaseConnection

The type of phase connection, such as wye or delta.

URI

cim:EnergyConsumer.phaseConnection

Cardinality

0..1

Type

PhaseShuntConnectionKind

Inherited from

EnergyConsumer

PinEquipment

URI

cim:Equipment.PinEquipment

Cardinality

0..*

Type

PinEquipment

Inherited from

Equipment

PowerCutZone

The energy consumer is assigned to this power cut zone.

URI

cim:EnergyConsumer.PowerCutZone

Cardinality

0..1

Type

PowerCutZone

Inherited from

EnergyConsumer

PropertiesCIMDataObject

The single CIM data object in the appropriate dataset context.

URI

cim:IdentifiedObject.PropertiesCIMDataObject

Cardinality

0..1

Type

ChangeSetMember

Inherited from

IdentifiedObject

ProtectionEquipments

Protection equipment used to protect specific conducting equipment.

URI

cim:ConductingEquipment.ProtectionEquipments

Cardinality

0..*

Type

ProtectionEquipment

Inherited from

ConductingEquipment

ProtectiveActionAdjustment

The operating condition to the Conducting Equipment is changed when protective action adjustment is activated. For ShuntCompensator or other conducting equipment that operates on discrete values (integer), the values given in float will be rounded.

URI

cim:ConductingEquipment.ProtectiveActionAdjustment

Cardinality

0..*

Type

ProtectiveActionAdjustment

Inherited from

ConductingEquipment

ProtectiveActionEquipment

Protective action is controlling equipment. This can be direct signals from the control center, or emulation of action done by protection equipment.

URI

cim:Equipment.ProtectiveActionEquipment

Cardinality

0..*

Type

ProtectiveActionEquipment

Inherited from

Equipment

PSREvents

All events associated with this power system resource.

URI

cim:PowerSystemResource.PSREvents

Cardinality

0..*

Type

PSREvent

Inherited from

PowerSystemResource

PSRType

Custom classification for this power system resource.

URI

cim:PowerSystemResource.PSRType

Cardinality

0..1

Type

PSRType

Inherited from

PowerSystemResource

q

Reactive power of the load. Load sign convention is used, i.e. positive sign means flow out from a node. For voltage dependent loads the value is at rated voltage. Starting value for a steady state solution.

URI

cim:EnergyConsumer.q

Cardinality

0..1

Type

ReactivePower

Inherited from

EnergyConsumer

qfixed

Reactive power of the load that is a fixed quantity and does not vary as load group value varies. Load sign convention is used, i.e. positive sign means flow out from a node.

URI

cim:EnergyConsumer.qfixed

Cardinality

0..1

Type

ReactivePower

Inherited from

EnergyConsumer

qfixedPct

Fixed reactive power as a percentage of load group fixed reactive power. Used to represent the time-varying components. Load sign convention is used, i.e. positive sign means flow out from a node.

URI

cim:EnergyConsumer.qfixedPct

Cardinality

0..1

Type

PerCent

Inherited from

EnergyConsumer

ReportingGroup

Reporting groups to which this power system resource belongs.

URI

cim:PowerSystemResource.ReportingGroup

Cardinality

0..*

Type

ReportingGroup

Inherited from

PowerSystemResource

SvStatus

The status state variable associated with this conducting equipment.

URI

cim:ConductingEquipment.SvStatus

Cardinality

0..*

Type

SvStatus

Inherited from

ConductingEquipment

TargetingCIMDataObject

Data objects registered.

URI

cim:IdentifiedObject.TargetingCIMDataObject

Cardinality

0..*

Type

ChangeSetMember

Inherited from

IdentifiedObject

Terminals

Conducting equipment have terminals that may be connected to other conducting equipment terminals via connectivity nodes or topological nodes.

URI

cim:ConductingEquipment.Terminals

Cardinality

0..*

Type

Terminal

Inherited from

ConductingEquipment

UsagePoints

All usage points connected to the electrical grid through this equipment.

URI

cim:Equipment.UsagePoints

Cardinality

0..*

Type

UsagePoint

Inherited from

Equipment

VerificationAction

The verification action that is performed on the power system resource

URI

cim:PowerSystemResource.VerificationAction

Cardinality

0..*

Type

VerificationAction

Inherited from

PowerSystemResource

WeatherStation

URI

cim:Equipment.WeatherStation

Cardinality

0..*

Type

WeatherStation

Inherited from

Equipment

Used by

Source class Slot name

NonConformLoadGroup

EnergyConsumers