Instructions
Provides the necessary information (on a resource basis) to capture the Startup/Shutdown instruction results. This information is relevant to the DA Market (RUC only) as well as the RT Market (HASP, Pre-dispatch, and Interval).
Type |
Class |
---|---|
URI |
|
CIM standard (perspective) |
IEC62325 (Market) |
Slots
Name | Cardinality | Type | Description |
---|---|---|---|
1 |
n/a |
||
1..* |
n/a |
||
0..1 |
n/a |
||
0..1 |
Binding dispatch operating delta provides a relative delta to be applied. Typically used in demand response instructions. The bindingDOD instructions are cumulative; in other words a second DOD instruction does not replace the previous DOD, instead the second DOD adds to the previous DODs. |
||
0..1 |
n/a |
||
0..1 |
n/a |
||
0..1 |
Total cost associated with changing the status of the resource. |
||
0..1 |
instruction source for market quality results (INS, ACT) |
||
0..1 |
Time the resource should be at Pmin (for start ups). Time the resource is off line. |
||
0..1 |
Indicator of either a Start-Up or a Shut-Down. |
||
0..1 |
Manually Blocked Indicator (Yes/No). The instruction has been blocked by an Operator. |
||
0..1 |
Minimum start up time required to bring the unit online (minutes). SCUC commitment period start-up time. Calculated start up time based on the StartUpTimeCurve provided with the Bid. This is a combination of StartUp time bid and Unit down time. Units is minutes |
||
0..1 |
n/a |
||
0..1 |
n/a |
||
0..1 |
n/a |
bindingDOD
Binding dispatch operating delta provides a relative delta to be applied. Typically used in demand response instructions. The bindingDOD instructions are cumulative; in other words a second DOD instruction does not replace the previous DOD, instead the second DOD adds to the previous DODs.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
instructionCost
Total cost associated with changing the status of the resource.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
instructionSource
instruction source for market quality results (INS, ACT)
URI |
|
---|---|
Cardinality |
0..1 |
Type |
instructionStartTime
+++Time the resource should be at Pmin (for start ups).
Time the resource is off line.+
URI |
|
---|---|
Cardinality |
0..1 |
Type |
instructionType
Indicator of either a Start-Up or a Shut-Down.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
manuallyBlocked
Manually Blocked Indicator (Yes/No). The instruction has been blocked by an Operator.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
minStatusChangeTime
+++Minimum start up time required to bring the unit online (minutes).
SCUC commitment period start-up time. Calculated start up time based on the StartUpTimeCurve provided with the Bid.
This is a combination of StartUp time bid and Unit down time.
Units is minutes+++
URI |
|
---|---|
Cardinality |
0..1 |
Type |