OldSwitchInfo
Properties of switch assets.
Type |
Class |
---|---|
URI |
|
CIM standard (perspective) |
IEC61968 (Enterprise) |
Slots
Name | Cardinality | Type | Description |
---|---|---|---|
1 |
Dataset containing the data objects. |
||
0..1 |
The maximum rms voltage that may be applied across an open contact without breaking down the dielectric properties of the switch in the open position. |
||
0..1 |
True if switch has load breaking capabiity. Unless specified false, this is always assumed to be true for breakers and reclosers. |
||
0..1 |
The highest value of current the switch can make at the rated voltage under specified operating conditions without suffering significant deterioration of its performance. |
||
0..1 |
The lowest value of current that the switch can make, carry and break in uninterrupted duty at the rated voltage under specified operating conditions without suffering significant deterioration of its performance. |
||
0..1 |
Number of poles (i.e. of current carrying conductors that are switched). |
||
0..1 |
True if device is capable of being operated by remote control. |
||
0..1 |
The highest value of current the switch can carry in the closed position at the rated voltage under specified operating conditions without suffering significant deterioration of its performance. |
||
0..1 |
Asset information (nameplate) for this catalog asset type. |
||
0..1 |
Product asset model which conforms to this catalog asset type. |
||
0..1 |
The single CIM data object in the appropriate dataset context. |
||
0..1 |
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time. |
||
0..1 |
The maximum fault current a breaking device can break safely under prescribed conditions of use. |
||
0..1 |
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. |
||
0..1 |
Weight of gas in each tank of SF6 dead tank breaker. |
||
0..1 |
If true, it is a single phase switch. |
||
0..1 |
If true, the switch is not ganged (i.e., a switch phase may be operated separately from other phases). |
||
0..1 |
Gas or air pressure at or below which a low pressure alarm is generated. |
||
0..1 |
Gas or air pressure below which the breaker will not open. |
||
0..1 |
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. |
||
0..1 |
The name is any free human readable and possibly non unique text naming the object. |
||
0..1 |
Volume of oil in each tank of bulk oil breaker. |
||
0..1 |
Rated current. |
||
0..1 |
Frequency for which switch is rated. |
||
0..1 |
Rated impulse withstand voltage, also known as BIL (Basic Impulse Level). |
||
0..1 |
Switch rated interrupting time in seconds. |
||
0..1 |
Rated voltage. |
||
0..* |
All assets described by this data. |
||
0..* |
The diagram objects that are associated with the domain object. |
||
0..* |
All names of this identified object. |
||
0..* |
All power system resources with this datasheet information. |
||
0..* |
Data objects registered. |
aliasName
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Assets
All assets described by this data.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
breakingCapacity
The maximum fault current a breaking device can break safely under prescribed conditions of use.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
CatalogAssetType
Asset information (nameplate) for this catalog asset type.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
DiagramObjects
The diagram objects that are associated with the domain object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
dielectricStrength
The maximum rms voltage that may be applied across an open contact without breaking down the dielectric properties of the switch in the open position.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
gasWeightPerTank
Weight of gas in each tank of SF6 dead tank breaker.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
InstanceSet
Dataset containing the data objects.
URI |
|
---|---|
Cardinality |
1 |
Type |
|
Inherited from |
isSinglePhase
If true, it is a single phase switch.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
isUnganged
If true, the switch is not ganged (i.e., a switch phase may be operated separately from other phases).
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
loadBreak
True if switch has load breaking capabiity. Unless specified false, this is always assumed to be true for breakers and reclosers.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
lowPressureAlarm
Gas or air pressure at or below which a low pressure alarm is generated.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
lowPressureLockOut
Gas or air pressure below which the breaker will not open.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
makingCapacity
The highest value of current the switch can make at the rated voltage under specified operating conditions without suffering significant deterioration of its performance.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
minimumCurrent
The lowest value of current that the switch can make, carry and break in uninterrupted duty at the rated voltage under specified operating conditions without suffering significant deterioration of its performance.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
mRID
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
name
The name is any free human readable and possibly non unique text naming the object.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Names
All names of this identified object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
oilVolumePerTank
Volume of oil in each tank of bulk oil breaker.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
poleCount
Number of poles (i.e. of current carrying conductors that are switched).
URI |
|
---|---|
Cardinality |
0..1 |
Type |
PowerSystemResources
All power system resources with this datasheet information.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
ProductAssetModel
Product asset model which conforms to this catalog asset type.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
PropertiesCIMDataObject
The single CIM data object in the appropriate dataset context.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
ratedFrequency
Frequency for which switch is rated.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
ratedImpulseWithstandVoltage
Rated impulse withstand voltage, also known as BIL (Basic Impulse Level).
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
ratedInterruptingTime
Switch rated interrupting time in seconds.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
remote
True if device is capable of being operated by remote control.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
TargetingCIMDataObject
Data objects registered.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |