TransformerTankEnd
Transformer tank end represents an individual winding for unbalanced models or for transformer tanks connected into a bank (and bank is modelled with the PowerTransformer).
Type |
Class |
---|---|
URI |
|
CIM standard (perspective) |
IEC61970 (Grid) |
Slots
Name | Type | Description | Inherited from |
---|---|---|---|
0..1 |
Transformer this winding belongs to. |
n/a |
|
0..1 |
Describes the phases carried by a conducting equipment. |
n/a |
|
0..1 |
Base voltage of the transformer end. This is essential for PU calculation. |
||
Core admittance of this transformer end, representing magnetising current and core losses. The full values of the... |
|||
All mesh impedances between this 'to' and other 'from' transformer ends. |
|||
0..* |
n/a |
||
0..1 |
Phase tap changer associated with this transformer end. |
||
0..1 |
Ratio tap changer associated with this transformer end. |
||
(accurate for 2- or 3-winding transformers only) Pi-model impedances of this transformer end. By convention, for a two... |
|||
0..1 |
Terminal of the power transformer to which this transformer end belongs. |
||
All mesh impedances between this 'from' and other 'to' transformer ends. |
|||
0..* |
n/a |
||
0..1 |
Core shunt magnetizing susceptance in the saturation region. |
||
0..1 |
Number for this transformer end, corresponding to the end's order in the power transformer vector group or phase angle clock... |
||
0..1 |
(for Yn and Zn connections) True if the neutral is solidly grounded. |
||
0..1 |
The reference voltage at which the magnetizing saturation measurements were made. |
||
0..1 |
Core magnetizing saturation curve knee flux level. |
||
0..1 |
(for Yn and Zn connections) Resistance part of neutral impedance where 'grounded' is true. |
||
0..1 |
(for Yn and Zn connections) Reactive part of neutral impedance where 'grounded' is true. |
||
0..* |
The diagram objects that are associated with the domain object. |
||
Dataset containing the data objects. |
|||
0..* |
All names of this identified object. |
||
0..1 |
The single CIM data object in the appropriate dataset context. |
||
0..* |
Data objects registered. |
||
0..1 |
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and... |
||
0..1 |
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to... |
||
0..1 |
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is... |
||
0..1 |
The name is any free human readable and possibly non unique text naming the object. |
aliasName
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
BaseVoltage
Base voltage of the transformer end. This is essential for PU calculation.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
bmagSat
Core shunt magnetizing susceptance in the saturation region.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
CoreAdmittance
Core admittance of this transformer end, representing magnetising current and core losses. The full values of the transformer should be supplied for one transformer end only.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
DiagramObjects
The diagram objects that are associated with the domain object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
endNumber
Number for this transformer end, corresponding to the end's order in the power transformer vector group or phase angle clock number. Highest voltage winding should be 1. Each end within a power transformer should have a unique subsequent end number. Note the transformer end number need not match the terminal sequence number.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
FromMeshImpedance
All mesh impedances between this 'to' and other 'from' transformer ends.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
FromWindingInsulations
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
grounded
(for Yn and Zn connections) True if the neutral is solidly grounded.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
InstanceSet
Dataset containing the data objects.
URI |
|
---|---|
Cardinality |
1 |
Type |
|
Inherited from |
magBaseU
The reference voltage at which the magnetizing saturation measurements were made.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
magSatFlux
Core magnetizing saturation curve knee flux level.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
mRID
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
name
The name is any free human readable and possibly non unique text naming the object.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Names
All names of this identified object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
phases
Describes the phases carried by a conducting equipment.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
PhaseTapChanger
Phase tap changer associated with this transformer end.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
PropertiesCIMDataObject
The single CIM data object in the appropriate dataset context.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
RatioTapChanger
Ratio tap changer associated with this transformer end.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
rground
(for Yn and Zn connections) Resistance part of neutral impedance where 'grounded' is true.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
StarImpedance
(accurate for 2- or 3-winding transformers only) Pi-model impedances of this transformer end. By convention, for a two winding transformer, the full values of the transformer should be entered on the high voltage end (endNumber=1).
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
TargetingCIMDataObject
Data objects registered.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
Terminal
Terminal of the power transformer to which this transformer end belongs.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
ToMeshImpedance
All mesh impedances between this 'from' and other 'to' transformer ends.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
ToWindingInsulations
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
TransformerTank
Transformer this winding belongs to.
URI |
|
---|---|
Cardinality |
0..1 |
Type |