NonlinearShuntCompensatorPoint
A non linear shunt compensator bank or section admittance value. The number of NonlinearShuntCompenstorPoint instances associated with a NonlinearShuntCompensator shall be equal to ShuntCompensator.maximumSections. ShuntCompensator.sections shall only be set to one of the NonlinearShuntCompenstorPoint.sectionNumber. There is no interpolation between NonlinearShuntCompenstorPoint-s.
Type |
Class |
---|---|
URI |
|
CIM standard (perspective) |
IEC61970 (Grid) |
Slots
Name | Type | Description | Inherited from |
---|---|---|---|
Non-linear shunt compensator owning this point. |
n/a |
||
0..1 |
Positive sequence shunt (charging) susceptance per section. |
n/a |
|
0..1 |
Zero sequence shunt (charging) susceptance per section. |
n/a |
|
0..1 |
Positive sequence shunt (charging) conductance per section. |
n/a |
|
0..1 |
Zero sequence shunt (charging) conductance per section. |
n/a |
|
0..1 |
The number of the section. |
n/a |
b
Positive sequence shunt (charging) susceptance per section.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
b0
Zero sequence shunt (charging) susceptance per section.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
g
Positive sequence shunt (charging) conductance per section.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
g0
Zero sequence shunt (charging) conductance per section.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
NonlinearShuntCompensator
Non-linear shunt compensator owning this point.
URI |
|
---|---|
Cardinality |
1 |
Type |