EnvironmentalDiscrete
Discrete (integer) measurement of relevance in the environmental domain.
Type |
Class |
---|---|
URI |
|
CIM standard (perspective) |
IEC62325 (Market) |
Slots
Name | Cardinality | Type | Description |
---|---|---|---|
1 |
Kind of environmental discrete (integer). |
||
1 |
Dataset containing the data objects. |
||
0..1 |
Observation or forecast with which this environmental discrete (integer) is associated. |
||
0..1 |
Asset that has a measurement |
||
0..1 |
Calculation method hierarchy which applies to this analog. |
||
0..1 |
The measurement action that is performed on the measurement |
||
0..1 |
The power system resource that contains the measurement. |
||
0..1 |
The single CIM data object in the appropriate dataset context. |
||
0..1 |
One or more measurements may be associated with a terminal in the network. |
||
0..1 |
The ValueAliasSet used for translation of a MeasurementValue.value to a name. |
||
0..1 |
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time. |
||
0..1 |
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. |
||
0..1 |
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. |
||
0..1 |
Normal value range maximum for any of the MeasurementValue.values. Used for scaling, e.g. in bar graphs or of telemetered raw values. |
||
0..1 |
Specifies the type of measurement. For example, this specifies if the measurement represents an indoor temperature, outdoor temperature, bus voltage, line flow, etc. When the measurementType is set to "Specialization", the type of Measurement is defined in more detail by the specialized class which inherits from Measurement. |
||
0..1 |
Normal value range minimum for any of the MeasurementValue.values. Used for scaling, e.g. in bar graphs or of telemetered raw values. |
||
0..1 |
The name is any free human readable and possibly non unique text naming the object. |
||
0..1 |
Normal measurement value, e.g., used for percentage calculations. |
||
0..1 |
Indicates to which phases the measurement applies and avoids the need to use 'measurementType' to also encode phase information (which would explode the types). The phase information in Measurement, along with 'measurementType' and 'phases' uniquely defines a Measurement for a device, based on normal network phase. Their meaning will not change when the computed energizing phasing is changed due to jumpers or other reasons. If the attribute is missing three phases (ABC) shall be assumed. |
||
0..1 |
The unit multiplier of the measured quantity. |
||
0..1 |
The unit of measure of the measured quantity. |
||
0..* |
The diagram objects that are associated with the domain object. |
||
0..* |
The values connected to this measurement. |
||
0..* |
Location of this measurement. |
||
0..* |
n/a |
||
0..* |
All names of this identified object. |
||
0..* |
n/a |
||
0..* |
Measurements are specified in types of documents, such as procedures. |
||
0..* |
n/a |
||
0..* |
Data objects registered. |
aliasName
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
CalculationMethodHierarchy
Calculation method hierarchy which applies to this analog.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
DiagramObjects
The diagram objects that are associated with the domain object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
DiscreteValues
The values connected to this measurement.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
EnvironmentalInformation
Observation or forecast with which this environmental discrete (integer) is associated.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
InstanceSet
Dataset containing the data objects.
URI |
|
---|---|
Cardinality |
1 |
Type |
|
Inherited from |
kind
Kind of environmental discrete (integer).
URI |
|
---|---|
Cardinality |
1 |
Type |
Locations
Location of this measurement.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
maxValue
Normal value range maximum for any of the MeasurementValue.values. Used for scaling, e.g. in bar graphs or of telemetered raw values.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
MeasurementAction
The measurement action that is performed on the measurement
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
MeasurementCalculatorInput
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
measurementType
Specifies the type of measurement. For example, this specifies if the measurement represents an indoor temperature, outdoor temperature, bus voltage, line flow, etc. When the measurementType is set to "Specialization", the type of Measurement is defined in more detail by the specialized class which inherits from Measurement.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
minValue
Normal value range minimum for any of the MeasurementValue.values. Used for scaling, e.g. in bar graphs or of telemetered raw values.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
mRID
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
name
The name is any free human readable and possibly non unique text naming the object.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Names
All names of this identified object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
normalValue
Normal measurement value, e.g., used for percentage calculations.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
phases
Indicates to which phases the measurement applies and avoids the need to use 'measurementType' to also encode phase information (which would explode the types). The phase information in Measurement, along with 'measurementType' and 'phases' uniquely defines a Measurement for a device, based on normal network phase. Their meaning will not change when the computed energizing phasing is changed due to jumpers or other reasons. If the attribute is missing three phases (ABC) shall be assumed.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
PowerSystemResource
The power system resource that contains the measurement.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Procedures
Measurements are specified in types of documents, such as procedures.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
PropertiesCIMDataObject
The single CIM data object in the appropriate dataset context.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
ProtectiveActionAdjustment
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
TargetingCIMDataObject
Data objects registered.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
Terminal
One or more measurements may be associated with a terminal in the network.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
unitMultiplier
The unit multiplier of the measured quantity.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
unitSymbol
The unit of measure of the measured quantity.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |