RemoteConnectDisconnectInfo
Details of remote connect and disconnect function.
Type |
Class |
---|---|
URI |
|
CIM standard (perspective) |
IEC61968 (Enterprise) |
Slots
Name | Cardinality | Type | Description |
---|---|---|---|
0..1 |
Setting of the timeout elapsed time. |
||
0..1 |
Voltage limit on customer side of RCD switch above which the connect should not be made. |
||
0..1 |
Limit of energy before disconnect. |
||
0..1 |
Start date and time to accumulate energy for energy usage limiting. |
||
0..1 |
Warning energy limit, used to trigger event code that energy usage is nearing limit. |
||
0..1 |
True if the RCD switch has to be armed before a connect action can be initiated. |
||
0..1 |
True if the RCD switch has to be armed before a disconnect action can be initiated. |
||
0..1 |
True if the energy usage is limited and the customer will be disconnected if they go over the limit. |
||
0..1 |
True if load limit has to be checked to issue an immediate disconnect (after a connect) if load is over the limit. |
||
0..1 |
True if voltage limit has to be checked to prevent connect if voltage is over the limit. |
||
0..1 |
Load limit above which the connect should either not take place or should cause an immediate disconnect. |
||
0..1 |
True if pushbutton has to be used for connect. |
armedTimeout
Setting of the timeout elapsed time.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
customerVoltageLimit
Voltage limit on customer side of RCD switch above which the connect should not be made.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
energyLimit
Limit of energy before disconnect.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
energyUsageStartDateTime
Start date and time to accumulate energy for energy usage limiting.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
energyUsageWarning
Warning energy limit, used to trigger event code that energy usage is nearing limit.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
isArmConnect
True if the RCD switch has to be armed before a connect action can be initiated.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
isArmDisconnect
True if the RCD switch has to be armed before a disconnect action can be initiated.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
isEnergyLimiting
True if the energy usage is limited and the customer will be disconnected if they go over the limit.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
needsPowerLimitCheck
True if load limit has to be checked to issue an immediate disconnect (after a connect) if load is over the limit.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
needsVoltageLimitCheck
True if voltage limit has to be checked to prevent connect if voltage is over the limit.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
powerLimit
Load limit above which the connect should either not take place or should cause an immediate disconnect.
URI |
|
---|---|
Cardinality |
0..1 |
Type |