TieLine
Type |
Class |
---|---|
URI |
|
CIM standard (perspective) |
IEC62325 (Market) |
Slots
Name | Cardinality | Type | Description |
---|---|---|---|
1 |
The SubControlArea is on the A side of a collection of metered points which define the SubControlArea's boundary for a ControlAreaOperator or CustomerConsumer. |
||
1 |
The SubControlArea is on the B side of a collection of metered points which define the SubControlArea's boundary for a ControlAreaOperator or CustomerConsumer. |
||
1 |
Dataset containing the data objects. |
||
0..1 |
A dynamic energy transaction can act as a pseudo tie line. |
||
0..1 |
A CustomerConsumer may ring its perimeter with metering, which can create a unique SubControlArea at the collection of metering points, called a TieLine. |
||
0..* |
A ControlAreaOperator has a collection of tie points that ring the ControlArea, called a TieLine. |
||
0..1 |
The single CIM data object in the appropriate dataset context. |
||
0..1 |
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time. |
||
0..1 |
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. |
||
0..1 |
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. |
||
0..1 |
The name is any free human readable and possibly non unique text naming the object. |
||
0..* |
The diagram objects that are associated with the domain object. |
||
0..* |
All names of this identified object. |
||
0..* |
Data objects registered. |
aliasName
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
DiagramObjects
The diagram objects that are associated with the domain object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
EnergyTransaction
A dynamic energy transaction can act as a pseudo tie line.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
InstanceSet
Dataset containing the data objects.
URI |
|
---|---|
Cardinality |
1 |
Type |
|
Inherited from |
mRID
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
name
The name is any free human readable and possibly non unique text naming the object.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Names
All names of this identified object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
ParentOfA
A ControlAreaOperator has a collection of tie points that ring the ControlArea, called a TieLine.
URI |
|
---|---|
Cardinality |
0..* |
Type |
ParentOfB
A CustomerConsumer may ring its perimeter with metering, which can create a unique SubControlArea at the collection of metering points, called a TieLine.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
PropertiesCIMDataObject
The single CIM data object in the appropriate dataset context.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
SideA_SubControlArea
The SubControlArea is on the A side of a collection of metered points which define the SubControlArea's boundary for a ControlAreaOperator or CustomerConsumer.
URI |
|
---|---|
Cardinality |
1 |
Type |
SideB_SubControlArea
The SubControlArea is on the B side of a collection of metered points which define the SubControlArea's boundary for a ControlAreaOperator or CustomerConsumer.
URI |
|
---|---|
Cardinality |
1 |
Type |