TapChangerInfo

Tap changer data.

Type

Class

URI

cim:TapChangerInfo

CIM standard (perspective)

IEC61968 (Enterprise)

Class hierarchy

Slots

Associated classes
Figure 1. Associated classes
Name Cardinality Type Description

InstanceSet

1

InstanceSet

Dataset containing the data objects.

bil

0..1

Voltage

Basic Insulation Level (BIL) expressed as the impulse crest voltage of a nominal wave, typically 1.2 X 50 microsecond. This is a measure of the ability of the insulation to withstand very high voltage surges.

ctRating

0..1

CurrentFlow

Built-in current transformer primary rating.

ctRatio

0..1

float

Built-in current transducer ratio.

frequency

0..1

Frequency

Frequency at which the ratings apply.

highStep

0..1

integer

Highest possible tap step position, advance from neutral.

isTcul

0..1

boolean

Whether this tap changer has under load tap changing capabilities.

lowStep

0..1

integer

Lowest possible tap step position, retard from neutral.

neutralStep

0..1

integer

The neutral tap step position for the winding.

neutralU

0..1

Voltage

Voltage at which the winding operates at the neutral tap setting.

ptRatio

0..1

float

Built-in voltage transducer ratio.

ratedApparentPower

0..1

ApparentPower

Rated apparent power.

ratedCurrent

0..1

CurrentFlow

Rated current.

ratedVoltage

0..1

Voltage

Rated voltage.

stepPhaseIncrement

0..1

AngleDegrees

Phase shift per step position.

stepVoltageIncrement

0..1

PerCent

Tap step increment, in per cent of rated voltage, per step position.

CatalogAssetType

0..1

CatalogAssetType

Asset information (nameplate) for this catalog asset type.

ProductAssetModel

0..1

ProductAssetModel

Product asset model which conforms to this catalog asset type.

PropertiesCIMDataObject

0..1

ChangeSetMember

The single CIM data object in the appropriate dataset context.

aliasName

0..1

string

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

description

0..1

string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

mRID

0..1

string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

name

0..1

string

The name is any free human readable and possibly non unique text naming the object.

Assets

0..*

Asset

All assets described by this data.

DiagramObjects

0..*

DiagramObject

The diagram objects that are associated with the domain object.

Names

0..*

Name

All names of this identified object.

PowerSystemResources

0..*

PowerSystemResource

All power system resources with this datasheet information.

TargetingCIMDataObject

0..*

ChangeSetMember

Data objects registered.


aliasName

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

URI

cim:IdentifiedObject.aliasName

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

Assets

All assets described by this data.

URI

cim:AssetInfo.Assets

Cardinality

0..*

Type

Asset

Inherited from

AssetInfo

bil

Basic Insulation Level (BIL) expressed as the impulse crest voltage of a nominal wave, typically 1.2 X 50 microsecond. This is a measure of the ability of the insulation to withstand very high voltage surges.

URI

cim:TapChangerInfo.bil

Cardinality

0..1

Type

Voltage

CatalogAssetType

Asset information (nameplate) for this catalog asset type.

URI

cim:AssetInfo.CatalogAssetType

Cardinality

0..1

Type

CatalogAssetType

Inherited from

AssetInfo

ctRating

Built-in current transformer primary rating.

URI

cim:TapChangerInfo.ctRating

Cardinality

0..1

Type

CurrentFlow

ctRatio

Built-in current transducer ratio.

URI

cim:TapChangerInfo.ctRatio

Cardinality

0..1

Type

float

description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

URI

cim:IdentifiedObject.description

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

DiagramObjects

The diagram objects that are associated with the domain object.

URI

cim:IdentifiedObject.DiagramObjects

Cardinality

0..*

Type

DiagramObject

Inherited from

IdentifiedObject

frequency

Frequency at which the ratings apply.

URI

cim:TapChangerInfo.frequency

Cardinality

0..1

Type

Frequency

highStep

Highest possible tap step position, advance from neutral.

URI

cim:TapChangerInfo.highStep

Cardinality

0..1

Type

integer

InstanceSet

Dataset containing the data objects.

URI

cim:IdentifiedObject.InstanceSet

Cardinality

1

Type

InstanceSet

Inherited from

IdentifiedObject

isTcul

Whether this tap changer has under load tap changing capabilities.

URI

cim:TapChangerInfo.isTcul

Cardinality

0..1

Type

boolean

lowStep

Lowest possible tap step position, retard from neutral.

URI

cim:TapChangerInfo.lowStep

Cardinality

0..1

Type

integer

mRID

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

URI

cim:IdentifiedObject.mRID

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

name

The name is any free human readable and possibly non unique text naming the object.

URI

cim:IdentifiedObject.name

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

Names

All names of this identified object.

URI

cim:IdentifiedObject.Names

Cardinality

0..*

Type

Name

Inherited from

IdentifiedObject

neutralStep

The neutral tap step position for the winding.

URI

cim:TapChangerInfo.neutralStep

Cardinality

0..1

Type

integer

neutralU

Voltage at which the winding operates at the neutral tap setting.

URI

cim:TapChangerInfo.neutralU

Cardinality

0..1

Type

Voltage

PowerSystemResources

All power system resources with this datasheet information.

URI

cim:AssetInfo.PowerSystemResources

Cardinality

0..*

Type

PowerSystemResource

Inherited from

AssetInfo

ProductAssetModel

Product asset model which conforms to this catalog asset type.

URI

cim:AssetInfo.ProductAssetModel

Cardinality

0..1

Type

ProductAssetModel

Inherited from

AssetInfo

PropertiesCIMDataObject

The single CIM data object in the appropriate dataset context.

URI

cim:IdentifiedObject.PropertiesCIMDataObject

Cardinality

0..1

Type

ChangeSetMember

Inherited from

IdentifiedObject

ptRatio

Built-in voltage transducer ratio.

URI

cim:TapChangerInfo.ptRatio

Cardinality

0..1

Type

float

ratedApparentPower

Rated apparent power.

URI

cim:TapChangerInfo.ratedApparentPower

Cardinality

0..1

Type

ApparentPower

ratedCurrent

Rated current.

URI

cim:TapChangerInfo.ratedCurrent

Cardinality

0..1

Type

CurrentFlow

ratedVoltage

Rated voltage.

URI

cim:TapChangerInfo.ratedVoltage

Cardinality

0..1

Type

Voltage

stepPhaseIncrement

Phase shift per step position.

URI

cim:TapChangerInfo.stepPhaseIncrement

Cardinality

0..1

Type

AngleDegrees

stepVoltageIncrement

Tap step increment, in per cent of rated voltage, per step position.

URI

cim:TapChangerInfo.stepVoltageIncrement

Cardinality

0..1

Type

PerCent

TargetingCIMDataObject

Data objects registered.

URI

cim:IdentifiedObject.TargetingCIMDataObject

Cardinality

0..*

Type

ChangeSetMember

Inherited from

IdentifiedObject