TapChanger
Mechanism for changing transformer winding tap positions.
Type |
Class |
---|---|
URI |
|
CIM standard (perspective) |
IEC61970 (Grid) |
Slots
Name | Type | Description | Inherited from |
---|---|---|---|
0..1 |
The tap step state associated with the tap changer. |
n/a |
|
0..1 |
The regulating control scheme in which this tap changer participates. |
n/a |
|
0..* |
A TapChanger can have TapSchedules. |
n/a |
|
0..1 |
Specifies the regulation status of the equipment. True is regulating, false is not regulating. |
n/a |
|
0..1 |
Highest possible tap step position, advance from neutral. The attribute shall be greater than lowStep. |
n/a |
|
0..1 |
For an LTC, the delay for initial tap changer operation (first step change). |
n/a |
|
0..1 |
Lowest possible tap step position, retard from neutral. |
n/a |
|
0..1 |
Specifies whether or not a TapChanger has load tap changing capabilities. |
n/a |
|
0..1 |
The neutral tap step position for this winding. The attribute shall be equal to or greater than lowStep and equal or less... |
n/a |
|
0..1 |
Voltage at which the winding operates at the neutral tap setting. It is the voltage at the terminal of the... |
n/a |
|
0..1 |
The tap step position used in "normal" network operation for this winding. For a "Fixed" tap changer indicates the current... |
n/a |
|
0..1 |
Tap changer position. Starting step for a steady state solution. Non integer values are allowed to support continuous tap... |
n/a |
|
0..1 |
For an LTC, the delay for subsequent tap changer operation (second and later step changes). |
n/a |
|
0..1 |
Datasheet information for this power system resource. |
||
0..* |
All assets represented by this power system resource. For example, multiple conductor assets are electrically modelled as a... |
||
0..* |
All clearances applicable to this power system resource. |
||
0..* |
All configuration events created for this Power System resource. |
||
0..* |
The controller outputs used to actually govern a regulating device, e.g. the magnetization of a synchronous machine or... |
||
0..* |
The generic action that is performed on the power system resource |
||
0..1 |
Location of this power system resource. |
||
0..* |
The measurements associated with this power system resource. |
||
0..* |
The operating shares of this power system resource. |
||
0..* |
All operational tags placed on this power system resource. |
||
0..* |
All events associated with this power system resource. |
||
0..1 |
Custom classification for this power system resource. |
||
0..* |
Reporting groups to which this power system resource belongs. |
||
0..* |
The verification action that is performed on the power system resource |
||
0..* |
The diagram objects that are associated with the domain object. |
||
Dataset containing the data objects. |
|||
0..* |
All names of this identified object. |
||
0..1 |
The single CIM data object in the appropriate dataset context. |
||
0..* |
Data objects registered. |
||
0..1 |
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and... |
||
0..1 |
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to... |
||
0..1 |
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is... |
||
0..1 |
The name is any free human readable and possibly non unique text naming the object. |
aliasName
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
AssetDatasheet
Datasheet information for this power system resource.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Assets
All assets represented by this power system resource. For example, multiple conductor assets are electrically modelled as a single AC line segment.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
Clearances
All clearances applicable to this power system resource.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
ConfigurationEvent
All configuration events created for this Power System resource.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
controlEnabled
Specifies the regulation status of the equipment. True is regulating, false is not regulating.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
Controls
The controller outputs used to actually govern a regulating device, e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
DiagramObjects
The diagram objects that are associated with the domain object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
GenericAction
The generic action that is performed on the power system resource
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
highStep
Highest possible tap step position, advance from neutral. The attribute shall be greater than lowStep.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
initialDelay
For an LTC, the delay for initial tap changer operation (first step change).
URI |
|
---|---|
Cardinality |
0..1 |
Type |
InstanceSet
Dataset containing the data objects.
URI |
|
---|---|
Cardinality |
1 |
Type |
|
Inherited from |
Location
Location of this power system resource.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
lowStep
Lowest possible tap step position, retard from neutral.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
ltcFlag
Specifies whether or not a TapChanger has load tap changing capabilities.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
Measurements
The measurements associated with this power system resource.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
mRID
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
name
The name is any free human readable and possibly non unique text naming the object.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
Names
All names of this identified object.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
neutralStep
The neutral tap step position for this winding. The attribute shall be equal to or greater than lowStep and equal or less than highStep. It is the step position where the voltage is neutralU when the other terminals of the transformer are at the ratedU. If there are other tap changers on the transformer those taps are kept constant at their neutralStep.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
neutralU
Voltage at which the winding operates at the neutral tap setting. It is the voltage at the terminal of the PowerTransformerEnd associated with the tap changer when all tap changers on the transformer are at their neutralStep position. Normally neutralU of the tap changer is the same as ratedU of the PowerTransformerEnd, but it can differ in special cases such as when the tapping mechanism is separate from the winding more common on lower voltage transformers. This attribute is not relevant for PhaseTapChangerAsymmetrical, PhaseTapChangerSymmetrical and PhaseTapChangerLinear.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
normalStep
The tap step position used in "normal" network operation for this winding. For a "Fixed" tap changer indicates the current physical tap setting. The attribute shall be equal to or greater than lowStep and equal to or less than highStep.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
OperatingShare
The operating shares of this power system resource.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
OperationalTags
All operational tags placed on this power system resource.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
PropertiesCIMDataObject
The single CIM data object in the appropriate dataset context.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
PSREvents
All events associated with this power system resource.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
PSRType
Custom classification for this power system resource.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
ReportingGroup
Reporting groups to which this power system resource belongs.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |
step
Tap changer position. Starting step for a steady state solution. Non integer values are allowed to support continuous tap variables. The reasons for continuous value are to support study cases where no discrete tap changer has yet been designed, a solution where a narrow voltage band forces the tap step to oscillate or to accommodate for a continuous solution as input. The attribute shall be equal to or greater than lowStep and equal to or less than highStep.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
subsequentDelay
For an LTC, the delay for subsequent tap changer operation (second and later step changes).
URI |
|
---|---|
Cardinality |
0..1 |
Type |
SvTapStep
The tap step state associated with the tap changer.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
TapChangerControl
The regulating control scheme in which this tap changer participates.
URI |
|
---|---|
Cardinality |
0..1 |
Type |
TapSchedules
A TapChanger can have TapSchedules.
URI |
|
---|---|
Cardinality |
0..* |
Type |
TargetingCIMDataObject
Data objects registered.
URI |
|
---|---|
Cardinality |
0..* |
Type |
|
Inherited from |