PinEquipment

Value associated with Equipment is used as compare.

Type

Class

URI

cim:PinEquipment

CIM standard (perspective)

IEC61970 (Grid)

Class hierarchy

Slots

Associated classes
Figure 1. Associated classes
Name Cardinality Type Description

Equipment

1

Equipment

The Equipment that should be used in compare.

Gate

1

Gate

n/a

InstanceSet

1

InstanceSet

Dataset containing the data objects.

kind

0..1

PinEquipmentKind

The compare operation done on the equipment.

PropertiesCIMDataObject

0..1

ChangeSetMember

The single CIM data object in the appropriate dataset context.

aDLogicKind

0..1

AnalogToDigitalLogicKind

The compare operation.

absoluteValue

0..1

boolean

If true, use the absolute value for compare..

aliasName

0..1

string

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

description

0..1

string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

duration

0..1

Seconds

The duration the compare condition need to be present before given a true. Default is 0 seconds.

mRID

0..1

string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

name

0..1

string

The name is any free human readable and possibly non unique text naming the object.

negate

0..1

boolean

Invert/negate the result of the compare.

thresholdPercentage

0..1

PerCent

The threshold percentage that should be used for compare with the percentage change between input value and threshold value.

thresholdValue

0..1

float

The threshold value that should be used for compare with the input value.

DiagramObjects

0..*

DiagramObject

The diagram objects that are associated with the domain object.

Names

0..*

Name

All names of this identified object.

TargetingCIMDataObject

0..*

ChangeSetMember

Data objects registered.


absoluteValue

If true, use the absolute value for compare..

URI

cim:GateInputPin.absoluteValue

Cardinality

0..1

Type

boolean

Inherited from

GateInputPin

aDLogicKind

The compare operation.

URI

cim:GateInputPin.aDLogicKind

Cardinality

0..1

Type

AnalogToDigitalLogicKind

Inherited from

GateInputPin

aliasName

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

URI

cim:IdentifiedObject.aliasName

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

URI

cim:IdentifiedObject.description

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

DiagramObjects

The diagram objects that are associated with the domain object.

URI

cim:IdentifiedObject.DiagramObjects

Cardinality

0..*

Type

DiagramObject

Inherited from

IdentifiedObject

duration

The duration the compare condition need to be present before given a true. Default is 0 seconds.

URI

cim:GateInputPin.duration

Cardinality

0..1

Type

Seconds

Inherited from

GateInputPin

Equipment

The Equipment that should be used in compare.

URI

cim:PinEquipment.Equipment

Cardinality

1

Type

Equipment

Gate

URI

cim:GateInputPin.Gate

Cardinality

1

Type

Gate

Inherited from

GateInputPin

InstanceSet

Dataset containing the data objects.

URI

cim:IdentifiedObject.InstanceSet

Cardinality

1

Type

InstanceSet

Inherited from

IdentifiedObject

kind

The compare operation done on the equipment.

URI

cim:PinEquipment.kind

Cardinality

0..1

Type

PinEquipmentKind

mRID

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

URI

cim:IdentifiedObject.mRID

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

name

The name is any free human readable and possibly non unique text naming the object.

URI

cim:IdentifiedObject.name

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

Names

All names of this identified object.

URI

cim:IdentifiedObject.Names

Cardinality

0..*

Type

Name

Inherited from

IdentifiedObject

negate

Invert/negate the result of the compare.

URI

cim:GateInputPin.negate

Cardinality

0..1

Type

boolean

Inherited from

GateInputPin

PropertiesCIMDataObject

The single CIM data object in the appropriate dataset context.

URI

cim:IdentifiedObject.PropertiesCIMDataObject

Cardinality

0..1

Type

ChangeSetMember

Inherited from

IdentifiedObject

TargetingCIMDataObject

Data objects registered.

URI

cim:IdentifiedObject.TargetingCIMDataObject

Cardinality

0..*

Type

ChangeSetMember

Inherited from

IdentifiedObject

thresholdPercentage

The threshold percentage that should be used for compare with the percentage change between input value and threshold value.

URI

cim:GateInputPin.thresholdPercentage

Cardinality

0..1

Type

PerCent

Inherited from

GateInputPin

thresholdValue

The threshold value that should be used for compare with the input value.

URI

cim:GateInputPin.thresholdValue

Cardinality

0..1

Type

float

Inherited from

GateInputPin