HeatRecoveryBoiler

The heat recovery system associated with combustion turbines in order to produce steam for combined cycle plants.

Type

Class

URI

cim:HeatRecoveryBoiler

CIM standard (perspective)

IEC61970 (Grid)

Slots

Associated classes
Figure 1. Associated classes
Name Cardinality Type Description

InstanceSet

1

InstanceSet

Dataset containing the data objects.

steamSupplyRating2

0..1

float

The steam supply rating in kilopounds per hour, if dual pressure boiler.

CombustionTurbines

0..*

CombustionTurbine

A combustion turbine may have a heat recovery boiler for making steam.

AssetDatasheet

0..1

AssetInfo

Datasheet information for this power system resource.

Location

0..1

Location

Location of this power system resource.

PSRType

0..1

PSRType

Custom classification for this power system resource.

PropertiesCIMDataObject

0..1

ChangeSetMember

The single CIM data object in the appropriate dataset context.

aliasName

0..1

string

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

auxPowerVersusFrequency

0..1

PU

Off nominal frequency effect on auxiliary real power. Per unit active power variation versus per unit frequency variation.

auxPowerVersusVoltage

0..1

PU

Off nominal voltage effect on auxiliary real power. Per unit active power variation versus per unit voltage variation.

boilerControlMode

0..1

BoilerControlMode

The control mode of the boiler.

controlErrorBiasP

0..1

float

Active power error bias ratio.

controlIC

0..1

float

Integral constant.

controlPC

0..1

float

Proportional constant.

controlPEB

0..1

float

Pressure error bias ratio.

controlPED

0..1

PU

Pressure error deadband.

controlTC

0..1

float

Time constant.

description

0..1

string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

feedWaterIG

0..1

float

Feedwater integral gain ratio.

feedWaterPG

0..1

float

Feedwater proportional gain ratio.

feedWaterTC

0..1

Seconds

Feedwater time constant ratio.

fuelDemandLimit

0..1

PU

Fuel demand limit.

fuelSupplyDelay

0..1

Seconds

Fuel delay.

fuelSupplyTC

0..1

Seconds

Fuel supply time constant.

mRID

0..1

string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

maxErrorRateP

0..1

float

Active power maximum error rate limit.

mechPowerSensorLag

0..1

Seconds

Mechanical power sensor lag.

minErrorRateP

0..1

float

Active power minimum error rate limit.

name

0..1

string

The name is any free human readable and possibly non unique text naming the object.

pressureCtrlDG

0..1

float

Pressure control derivative gain ratio.

pressureCtrlIG

0..1

float

Pressure control integral gain ratio.

pressureCtrlPG

0..1

float

Pressure control proportional gain ratio.

pressureFeedback

0..1

integer

Pressure feedback indicator.

steamSupplyRating

0..1

float

Rating of steam supply.

superHeater1Capacity

0..1

float

Drum/primary superheater capacity.

superHeater2Capacity

0..1

float

Secondary superheater capacity.

superHeaterPipePD

0..1

float

Superheater pipe pressure drop constant.

throttlePressureSP

0..1

PU

Throttle pressure setpoint.

Assets

0..*

Asset

All assets represented by this power system resource. For example, multiple conductor assets are electrically modelled as a single AC line segment.

Clearances

0..*

ClearanceDocument

All clearances applicable to this power system resource.

ConfigurationEvent

0..*

ConfigurationEvent

All configuration events created for this Power System resource.

Controls

0..*

Control

The controller outputs used to actually govern a regulating device, e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator.

DiagramObjects

0..*

DiagramObject

The diagram objects that are associated with the domain object.

GenericAction

0..*

GenericAction

The generic action that is performed on the power system resource

Measurements

0..*

Measurement

The measurements associated with this power system resource.

Names

0..*

Name

All names of this identified object.

OperatingShare

0..*

OperatingShare

The operating shares of this power system resource.

OperationalTags

0..*

OperationalTag

All operational tags placed on this power system resource.

PSREvents

0..*

PSREvent

All events associated with this power system resource.

ReportingGroup

0..*

ReportingGroup

Reporting groups to which this power system resource belongs.

SteamTurbines

0..*

SteamTurbine

Steam turbines may have steam supplied by a steam supply.

TargetingCIMDataObject

0..*

ChangeSetMember

Data objects registered.

VerificationAction

0..*

VerificationAction

The verification action that is performed on the power system resource


aliasName

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

URI

cim:IdentifiedObject.aliasName

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

AssetDatasheet

Datasheet information for this power system resource.

URI

cim:PowerSystemResource.AssetDatasheet

Cardinality

0..1

Type

AssetInfo

Inherited from

PowerSystemResource

Assets

All assets represented by this power system resource. For example, multiple conductor assets are electrically modelled as a single AC line segment.

URI

cim:PowerSystemResource.Assets

Cardinality

0..*

Type

Asset

Inherited from

PowerSystemResource

auxPowerVersusFrequency

Off nominal frequency effect on auxiliary real power. Per unit active power variation versus per unit frequency variation.

URI

cim:FossilSteamSupply.auxPowerVersusFrequency

Cardinality

0..1

Type

PU

Inherited from

FossilSteamSupply

auxPowerVersusVoltage

Off nominal voltage effect on auxiliary real power. Per unit active power variation versus per unit voltage variation.

URI

cim:FossilSteamSupply.auxPowerVersusVoltage

Cardinality

0..1

Type

PU

Inherited from

FossilSteamSupply

boilerControlMode

The control mode of the boiler.

URI

cim:FossilSteamSupply.boilerControlMode

Cardinality

0..1

Type

BoilerControlMode

Inherited from

FossilSteamSupply

Clearances

All clearances applicable to this power system resource.

URI

cim:PowerSystemResource.Clearances

Cardinality

0..*

Type

ClearanceDocument

Inherited from

PowerSystemResource

CombustionTurbines

A combustion turbine may have a heat recovery boiler for making steam.

URI

cim:HeatRecoveryBoiler.CombustionTurbines

Cardinality

0..*

Type

CombustionTurbine

ConfigurationEvent

All configuration events created for this Power System resource.

URI

cim:PowerSystemResource.ConfigurationEvent

Cardinality

0..*

Type

ConfigurationEvent

Inherited from

PowerSystemResource

controlErrorBiasP

Active power error bias ratio.

URI

cim:FossilSteamSupply.controlErrorBiasP

Cardinality

0..1

Type

float

Inherited from

FossilSteamSupply

controlIC

Integral constant.

URI

cim:FossilSteamSupply.controlIC

Cardinality

0..1

Type

float

Inherited from

FossilSteamSupply

controlPC

Proportional constant.

URI

cim:FossilSteamSupply.controlPC

Cardinality

0..1

Type

float

Inherited from

FossilSteamSupply

controlPEB

Pressure error bias ratio.

URI

cim:FossilSteamSupply.controlPEB

Cardinality

0..1

Type

float

Inherited from

FossilSteamSupply

controlPED

Pressure error deadband.

URI

cim:FossilSteamSupply.controlPED

Cardinality

0..1

Type

PU

Inherited from

FossilSteamSupply

Controls

The controller outputs used to actually govern a regulating device, e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator.

URI

cim:PowerSystemResource.Controls

Cardinality

0..*

Type

Control

Inherited from

PowerSystemResource

controlTC

Time constant.

URI

cim:FossilSteamSupply.controlTC

Cardinality

0..1

Type

float

Inherited from

FossilSteamSupply

description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

URI

cim:IdentifiedObject.description

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

DiagramObjects

The diagram objects that are associated with the domain object.

URI

cim:IdentifiedObject.DiagramObjects

Cardinality

0..*

Type

DiagramObject

Inherited from

IdentifiedObject

feedWaterIG

Feedwater integral gain ratio.

URI

cim:FossilSteamSupply.feedWaterIG

Cardinality

0..1

Type

float

Inherited from

FossilSteamSupply

feedWaterPG

Feedwater proportional gain ratio.

URI

cim:FossilSteamSupply.feedWaterPG

Cardinality

0..1

Type

float

Inherited from

FossilSteamSupply

feedWaterTC

Feedwater time constant ratio.

URI

cim:FossilSteamSupply.feedWaterTC

Cardinality

0..1

Type

Seconds

Inherited from

FossilSteamSupply

fuelDemandLimit

Fuel demand limit.

URI

cim:FossilSteamSupply.fuelDemandLimit

Cardinality

0..1

Type

PU

Inherited from

FossilSteamSupply

fuelSupplyDelay

Fuel delay.

URI

cim:FossilSteamSupply.fuelSupplyDelay

Cardinality

0..1

Type

Seconds

Inherited from

FossilSteamSupply

fuelSupplyTC

Fuel supply time constant.

URI

cim:FossilSteamSupply.fuelSupplyTC

Cardinality

0..1

Type

Seconds

Inherited from

FossilSteamSupply

GenericAction

The generic action that is performed on the power system resource

URI

cim:PowerSystemResource.GenericAction

Cardinality

0..*

Type

GenericAction

Inherited from

PowerSystemResource

InstanceSet

Dataset containing the data objects.

URI

cim:IdentifiedObject.InstanceSet

Cardinality

1

Type

InstanceSet

Inherited from

IdentifiedObject

Location

Location of this power system resource.

URI

cim:PowerSystemResource.Location

Cardinality

0..1

Type

Location

Inherited from

PowerSystemResource

maxErrorRateP

Active power maximum error rate limit.

URI

cim:FossilSteamSupply.maxErrorRateP

Cardinality

0..1

Type

float

Inherited from

FossilSteamSupply

Measurements

The measurements associated with this power system resource.

URI

cim:PowerSystemResource.Measurements

Cardinality

0..*

Type

Measurement

Inherited from

PowerSystemResource

mechPowerSensorLag

Mechanical power sensor lag.

URI

cim:FossilSteamSupply.mechPowerSensorLag

Cardinality

0..1

Type

Seconds

Inherited from

FossilSteamSupply

minErrorRateP

Active power minimum error rate limit.

URI

cim:FossilSteamSupply.minErrorRateP

Cardinality

0..1

Type

float

Inherited from

FossilSteamSupply

mRID

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

URI

cim:IdentifiedObject.mRID

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

name

The name is any free human readable and possibly non unique text naming the object.

URI

cim:IdentifiedObject.name

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

Names

All names of this identified object.

URI

cim:IdentifiedObject.Names

Cardinality

0..*

Type

Name

Inherited from

IdentifiedObject

OperatingShare

The operating shares of this power system resource.

URI

cim:PowerSystemResource.OperatingShare

Cardinality

0..*

Type

OperatingShare

Inherited from

PowerSystemResource

OperationalTags

All operational tags placed on this power system resource.

URI

cim:PowerSystemResource.OperationalTags

Cardinality

0..*

Type

OperationalTag

Inherited from

PowerSystemResource

pressureCtrlDG

Pressure control derivative gain ratio.

URI

cim:FossilSteamSupply.pressureCtrlDG

Cardinality

0..1

Type

float

Inherited from

FossilSteamSupply

pressureCtrlIG

Pressure control integral gain ratio.

URI

cim:FossilSteamSupply.pressureCtrlIG

Cardinality

0..1

Type

float

Inherited from

FossilSteamSupply

pressureCtrlPG

Pressure control proportional gain ratio.

URI

cim:FossilSteamSupply.pressureCtrlPG

Cardinality

0..1

Type

float

Inherited from

FossilSteamSupply

pressureFeedback

Pressure feedback indicator.

URI

cim:FossilSteamSupply.pressureFeedback

Cardinality

0..1

Type

integer

Inherited from

FossilSteamSupply

PropertiesCIMDataObject

The single CIM data object in the appropriate dataset context.

URI

cim:IdentifiedObject.PropertiesCIMDataObject

Cardinality

0..1

Type

ChangeSetMember

Inherited from

IdentifiedObject

PSREvents

All events associated with this power system resource.

URI

cim:PowerSystemResource.PSREvents

Cardinality

0..*

Type

PSREvent

Inherited from

PowerSystemResource

PSRType

Custom classification for this power system resource.

URI

cim:PowerSystemResource.PSRType

Cardinality

0..1

Type

PSRType

Inherited from

PowerSystemResource

ReportingGroup

Reporting groups to which this power system resource belongs.

URI

cim:PowerSystemResource.ReportingGroup

Cardinality

0..*

Type

ReportingGroup

Inherited from

PowerSystemResource

steamSupplyRating

Rating of steam supply.

URI

cim:SteamSupply.steamSupplyRating

Cardinality

0..1

Type

float

Inherited from

SteamSupply

steamSupplyRating2

The steam supply rating in kilopounds per hour, if dual pressure boiler.

URI

cim:HeatRecoveryBoiler.steamSupplyRating2

Cardinality

0..1

Type

float

SteamTurbines

Steam turbines may have steam supplied by a steam supply.

URI

cim:SteamSupply.SteamTurbines

Cardinality

0..*

Type

SteamTurbine

Inherited from

SteamSupply

superHeater1Capacity

Drum/primary superheater capacity.

URI

cim:FossilSteamSupply.superHeater1Capacity

Cardinality

0..1

Type

float

Inherited from

FossilSteamSupply

superHeater2Capacity

Secondary superheater capacity.

URI

cim:FossilSteamSupply.superHeater2Capacity

Cardinality

0..1

Type

float

Inherited from

FossilSteamSupply

superHeaterPipePD

Superheater pipe pressure drop constant.

URI

cim:FossilSteamSupply.superHeaterPipePD

Cardinality

0..1

Type

float

Inherited from

FossilSteamSupply

TargetingCIMDataObject

Data objects registered.

URI

cim:IdentifiedObject.TargetingCIMDataObject

Cardinality

0..*

Type

ChangeSetMember

Inherited from

IdentifiedObject

throttlePressureSP

Throttle pressure setpoint.

URI

cim:FossilSteamSupply.throttlePressureSP

Cardinality

0..1

Type

PU

Inherited from

FossilSteamSupply

VerificationAction

The verification action that is performed on the power system resource

URI

cim:PowerSystemResource.VerificationAction

Cardinality

0..*

Type

VerificationAction

Inherited from

PowerSystemResource