Reading

Specific value measured by a meter or other asset, or calculated by a system. Each Reading is associated with a specific ReadingType.

Type

Class

URI

cim:Reading

CIM standard (perspective)

IEC61968 (Enterprise)

Slots

Name Type Description Inherited from

MeterReadings

0..*
MeterReading

All meter readings (sets of values) containing this reading value.

n/a

ReadingType

1
ReadingType

Type information for this reading value.

n/a

position

0..1
integer

A sequential value representing the relative position within a given time interval.

n/a

reason

0..1
ReadingReasonKind

Reason for this reading being taken.

n/a

valueMissing

0..1
boolean

The indication of whether or not the quantity of this reading is missing.

n/a

ReadingQualities

0..*
ReadingQuality

All qualities of this reading.

BaseReading

reportedDateTime

0..1
date

(used only when there are detailed auditing requirements) Date and time at which the reading was first delivered to the...

BaseReading

source

0..1
string

System that originally supplied the reading (e.g., customer, AMI system, handheld reading system, another enterprise system, etc.).

BaseReading

timePeriod

0..1
DateTimeInterval

Start and end of the period for those readings whose type has a time attribute such as 'billing', seasonal' or...

BaseReading

value

0..1
string

Value of this reading.

BaseReading

CalculationMethodHierarchy

0..1
CalculationMethodHierarchy

n/a

MeasurementValue

ErpPerson

0..1
OldPerson

n/a

MeasurementValue

MeasurementValueQuality

0..1
MeasurementValueQuality

A MeasurementValue has a MeasurementValueQuality associated with it.

MeasurementValue

MeasurementValueSource

1
MeasurementValueSource

A reference to the type of source that updates the MeasurementValue, e.g. SCADA, CCLink, manual, etc. User conventions for...

MeasurementValue

ProcedureDataSet

0..*
ProcedureDataSet

Procedure data set that applies to this mesurement value.

MeasurementValue

RemoteSource

0..1
RemoteSource

Link to the physical telemetered point associated with this measurement.

MeasurementValue

sensorAccuracy

0..1
PerCent

The limit, expressed as a percentage of the sensor maximum, that errors will not exceed when the sensor is used under ...

MeasurementValue

timeStamp

0..1
date

The time when the value was last updated.

MeasurementValue

BilateralToIOPoint

0..*
ProvidedBilateralPoint

Bilateral ICCP point for the measurement or control.

IOPoint

IOPointSource

0..1
IOPointSource

Local merasurement value source for an ICCP point.

IOPoint

DiagramObjects

0..*
DiagramObject

The diagram objects that are associated with the domain object.

IdentifiedObject

InstanceSet

1
InstanceSet

Dataset containing the data objects.

IdentifiedObject

Names

0..*
Name

All names of this identified object.

IdentifiedObject

PropertiesCIMDataObject

0..1
ChangeSetMember

The single CIM data object in the appropriate dataset context.

IdentifiedObject

TargetingCIMDataObject

0..*
ChangeSetMember

Data objects registered.

IdentifiedObject

aliasName

0..1
string

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and...

IdentifiedObject

description

0..1
string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to...

IdentifiedObject

mRID

0..1
string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is...

IdentifiedObject

name

0..1
string

The name is any free human readable and possibly non unique text naming the object.

IdentifiedObject


aliasName

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

URI

cim:IdentifiedObject.aliasName

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

BilateralToIOPoint

Bilateral ICCP point for the measurement or control.

URI

cim:IOPoint.BilateralToIOPoint

Cardinality

0..*

Type

ProvidedBilateralPoint

Inherited from

IOPoint

CalculationMethodHierarchy

URI

cim:MeasurementValue.CalculationMethodHierarchy

Cardinality

0..1

Type

CalculationMethodHierarchy

Inherited from

MeasurementValue

description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

URI

cim:IdentifiedObject.description

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

DiagramObjects

The diagram objects that are associated with the domain object.

URI

cim:IdentifiedObject.DiagramObjects

Cardinality

0..*

Type

DiagramObject

Inherited from

IdentifiedObject

ErpPerson

URI

cim:MeasurementValue.ErpPerson

Cardinality

0..1

Type

OldPerson

Inherited from

MeasurementValue

InstanceSet

Dataset containing the data objects.

URI

cim:IdentifiedObject.InstanceSet

Cardinality

1

Type

InstanceSet

Inherited from

IdentifiedObject

IOPointSource

Local merasurement value source for an ICCP point.

URI

cim:IOPoint.IOPointSource

Cardinality

0..1

Type

IOPointSource

Inherited from

IOPoint

MeasurementValueQuality

A MeasurementValue has a MeasurementValueQuality associated with it.

URI

cim:MeasurementValue.MeasurementValueQuality

Cardinality

0..1

Type

MeasurementValueQuality

Inherited from

MeasurementValue

MeasurementValueSource

A reference to the type of source that updates the MeasurementValue, e.g. SCADA, CCLink, manual, etc. User conventions for the names of sources are contained in the introduction to IEC 61970-301.

URI

cim:MeasurementValue.MeasurementValueSource

Cardinality

1

Type

MeasurementValueSource

Inherited from

MeasurementValue

MeterReadings

All meter readings (sets of values) containing this reading value.

URI

cim:Reading.MeterReadings

Cardinality

0..*

Type

MeterReading

mRID

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

URI

cim:IdentifiedObject.mRID

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

name

The name is any free human readable and possibly non unique text naming the object.

URI

cim:IdentifiedObject.name

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

Names

All names of this identified object.

URI

cim:IdentifiedObject.Names

Cardinality

0..*

Type

Name

Inherited from

IdentifiedObject

position

A sequential value representing the relative position within a given time interval.

URI

cim:Reading.position

Cardinality

0..1

Type

integer

ProcedureDataSet

Procedure data set that applies to this mesurement value.

URI

cim:MeasurementValue.ProcedureDataSet

Cardinality

0..*

Type

ProcedureDataSet

Inherited from

MeasurementValue

PropertiesCIMDataObject

The single CIM data object in the appropriate dataset context.

URI

cim:IdentifiedObject.PropertiesCIMDataObject

Cardinality

0..1

Type

ChangeSetMember

Inherited from

IdentifiedObject

ReadingQualities

All qualities of this reading.

URI

cim:BaseReading.ReadingQualities

Cardinality

0..*

Type

ReadingQuality

Inherited from

BaseReading

ReadingType

Type information for this reading value.

URI

cim:Reading.ReadingType

Cardinality

1

Type

ReadingType

reason

Reason for this reading being taken.

URI

cim:Reading.reason

Cardinality

0..1

Type

ReadingReasonKind

RemoteSource

Link to the physical telemetered point associated with this measurement.

URI

cim:MeasurementValue.RemoteSource

Cardinality

0..1

Type

RemoteSource

Inherited from

MeasurementValue

reportedDateTime

(used only when there are detailed auditing requirements) Date and time at which the reading was first delivered to the metering system.

URI

cim:BaseReading.reportedDateTime

Cardinality

0..1

Type

date

Inherited from

BaseReading

sensorAccuracy

The limit, expressed as a percentage of the sensor maximum, that errors will not exceed when the sensor is used under reference conditions.

URI

cim:MeasurementValue.sensorAccuracy

Cardinality

0..1

Type

PerCent

Inherited from

MeasurementValue

source

System that originally supplied the reading (e.g., customer, AMI system, handheld reading system, another enterprise system, etc.).

URI

cim:BaseReading.source

Cardinality

0..1

Type

string

Inherited from

BaseReading

TargetingCIMDataObject

Data objects registered.

URI

cim:IdentifiedObject.TargetingCIMDataObject

Cardinality

0..*

Type

ChangeSetMember

Inherited from

IdentifiedObject

timePeriod

Start and end of the period for those readings whose type has a time attribute such as 'billing', seasonal' or 'forTheSpecifiedPeriod'.

URI

cim:BaseReading.timePeriod

Cardinality

0..1

Type

DateTimeInterval

Inherited from

BaseReading

timeStamp

The time when the value was last updated.

URI

cim:MeasurementValue.timeStamp

Cardinality

0..1

Type

date

Inherited from

MeasurementValue

value

Value of this reading.

URI

cim:BaseReading.value

Cardinality

0..1

Type

string

Inherited from

BaseReading

valueMissing

The indication of whether or not the quantity of this reading is missing.

URI

cim:Reading.valueMissing

Cardinality

0..1

Type

boolean

Used by

Source class Slot name

MeterReading

Readings

ReadingType

Readings