DesignLocationCU

Compatible unit at a given design location.

Type

Class

URI

cim:DesignLocationCU

CIM standard (perspective)

IEC61968 (Enterprise)

Class hierarchy

Slots

Associated classes
Figure 1. Associated classes
Name Cardinality Type Description

InstanceSet

1

InstanceSet

Dataset containing the data objects.

DesignLocation

0..1

DesignLocation

n/a

cuAccount

0..1

string

A code that helps direct accounting (capital, expense, or accounting treatment).

cuAction

0..1

WorkActionKind

A code that instructs the crew what action to perform.

cuQuantity

0..1

IntegerQuantity

The quantity of the CU being assigned to this location.

cuUsage

0..1

string

As the same CU can be used for different purposes and accounting purposes, usage must be specified. Examples include: distribution, transmission, substation.

removalDate

0..1

date

Year when a CU that represents an asset is removed.

status

0..1

Status

n/a

toBeEnergised

0..1

boolean

True if associated electrical equipment is intended to be energized while work is being performed.

CUGroups

0..*

CUGroup

n/a

CompatibleUnits

0..*

CompatibleUnit

n/a

ConditionFactors

0..*

ConditionFactor

n/a

Designs

0..*

Design

n/a

WorkTasks

0..*

OldWorkTask

n/a

PropertiesCIMDataObject

0..1

ChangeSetMember

The single CIM data object in the appropriate dataset context.

aliasName

0..1

string

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

description

0..1

string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

mRID

0..1

string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

name

0..1

string

The name is any free human readable and possibly non unique text naming the object.

DiagramObjects

0..*

DiagramObject

The diagram objects that are associated with the domain object.

Names

0..*

Name

All names of this identified object.

TargetingCIMDataObject

0..*

ChangeSetMember

Data objects registered.


aliasName

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy. The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

URI

cim:IdentifiedObject.aliasName

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

CompatibleUnits

URI

cim:DesignLocationCU.CompatibleUnits

Cardinality

0..*

Type

CompatibleUnit

ConditionFactors

URI

cim:DesignLocationCU.ConditionFactors

Cardinality

0..*

Type

ConditionFactor

cuAccount

A code that helps direct accounting (capital, expense, or accounting treatment).

URI

cim:DesignLocationCU.cuAccount

Cardinality

0..1

Type

string

cuAction

A code that instructs the crew what action to perform.

URI

cim:DesignLocationCU.cuAction

Cardinality

0..1

Type

WorkActionKind

CUGroups

URI

cim:DesignLocationCU.CUGroups

Cardinality

0..*

Type

CUGroup

cuQuantity

The quantity of the CU being assigned to this location.

URI

cim:DesignLocationCU.cuQuantity

Cardinality

0..1

Type

IntegerQuantity

cuUsage

As the same CU can be used for different purposes and accounting purposes, usage must be specified. Examples include: distribution, transmission, substation.

URI

cim:DesignLocationCU.cuUsage

Cardinality

0..1

Type

string

description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

URI

cim:IdentifiedObject.description

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

DesignLocation

URI

cim:DesignLocationCU.DesignLocation

Cardinality

0..1

Type

DesignLocation

Designs

URI

cim:DesignLocationCU.Designs

Cardinality

0..*

Type

Design

DiagramObjects

The diagram objects that are associated with the domain object.

URI

cim:IdentifiedObject.DiagramObjects

Cardinality

0..*

Type

DiagramObject

Inherited from

IdentifiedObject

InstanceSet

Dataset containing the data objects.

URI

cim:IdentifiedObject.InstanceSet

Cardinality

1

Type

InstanceSet

Inherited from

IdentifiedObject

mRID

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

URI

cim:IdentifiedObject.mRID

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

name

The name is any free human readable and possibly non unique text naming the object.

URI

cim:IdentifiedObject.name

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

Names

All names of this identified object.

URI

cim:IdentifiedObject.Names

Cardinality

0..*

Type

Name

Inherited from

IdentifiedObject

PropertiesCIMDataObject

The single CIM data object in the appropriate dataset context.

URI

cim:IdentifiedObject.PropertiesCIMDataObject

Cardinality

0..1

Type

ChangeSetMember

Inherited from

IdentifiedObject

removalDate

Year when a CU that represents an asset is removed.

URI

cim:DesignLocationCU.removalDate

Cardinality

0..1

Type

date

status

URI

cim:DesignLocationCU.status

Cardinality

0..1

Type

Status

TargetingCIMDataObject

Data objects registered.

URI

cim:IdentifiedObject.TargetingCIMDataObject

Cardinality

0..*

Type

ChangeSetMember

Inherited from

IdentifiedObject

toBeEnergised

True if associated electrical equipment is intended to be energized while work is being performed.

URI

cim:DesignLocationCU.toBeEnergised

Cardinality

0..1

Type

boolean

WorkTasks

URI

cim:DesignLocationCU.WorkTasks

Cardinality

0..*

Type

OldWorkTask