DotInstruction

Provides the necessary information (on a resource basis) to capture the Dispatch Operating Target (DOT) results on a Dispatch interval. This information is only relevant to the RT interval market.

Type

Class

URI

cim:DotInstruction

CIM standard (perspective)

IEC62325 (Market)

Class hierarchy

  • DotInstruction

Slots

Associated classes
Figure 1. Associated classes
Name Cardinality Type Description

InstructionClearingDOT

1..*

InstructionClearingDOT

n/a

DOT

0..1

float

Dispatch operating target value.

RegisteredResource

0..1

RegisteredResource

n/a

actualRampRate

0..1

float

Actual ramp rate.

compliantIndicator

0..1

YesNo

Flag indicating whether or not the resource was in compliance with the instruction (plus/minus 10%).

Directs if a unit is allowed to set the price (ex-post pricing).

economicMaxOverride

0..1

float

Economic Max Limit override for unit, this value is null, if it is not, this value overrides the Energy column value. Allows dispatcher to override the unit's energy value.

expectedEnergy

0..1

float

Expected energy.

generatorPerformanceDegree

0..1

float

The Degree of Generator Performance (DGP) used for the unit. Measure of how a generator responds to raise /lower signals. Calculated every five minutes.

hourAheadSchedEnergy

0..1

float

HASP results.

hourlySchedule

0..1

float

Hourly Schedule (DA Energy Schedule).

instructionTime

0..1

date

The date/time for the instruction.

maximumEmergencyInd

0..1

boolean

True if maximum emergency limit activated; false otherwise. If unit is requested to move up to its max emergency limit., this flag is set to true.

meterLoadFollowing

0..1

float

Meter Sub System Load Following.

nonRampRestrictedMW

0..1

float

Desired MW that is not ramp restricted. If no ramp rate limit existed for the unit, this is the MW value tha t the unit was requested to move to.

nonSpinReserve

0..1

float

Non Spin Reserve used to procure energy.

previousDOTTimeStamp

0..1

date

Timestamp when the previous DOT value was issued.

rampRateLimit

0..1

float

The ramp rate limit for the unit in MWs per minute. Participant bidding data.

regulationStatus

0..1

YesNo

Regulation Status (Yes/No).

spinReserve

0..1

float

Spin Reserve used to procure energy.

standardRampEnergy

0..1

float

Standard ramping energy (MWH).

supplementalEnergy

0..1

float

Supplemental Energy procure by Real Time Dispatch.

unitStatus

0..1

integer

Output results from the case identifying the reason the unit was committed by the software.


actualRampRate

Actual ramp rate.

URI

cim:DotInstruction.actualRampRate

Cardinality

0..1

Type

float

compliantIndicator

+++Flag indicating whether or not the resource was in compliance with the instruction (plus/minus 10%).

Directs if a unit is allowed to set the price (ex-post pricing).+

URI

cim:DotInstruction.compliantIndicator

Cardinality

0..1

Type

YesNo

DOT

Dispatch operating target value.

URI

cim:DotInstruction.DOT

Cardinality

0..1

Type

float

economicMaxOverride

Economic Max Limit override for unit, this value is null, if it is not, this value overrides the Energy column value. Allows dispatcher to override the unit's energy value.

URI

cim:DotInstruction.economicMaxOverride

Cardinality

0..1

Type

float

expectedEnergy

Expected energy.

URI

cim:DotInstruction.expectedEnergy

Cardinality

0..1

Type

float

generatorPerformanceDegree

The Degree of Generator Performance (DGP) used for the unit. Measure of how a generator responds to raise /lower signals. Calculated every five minutes.

URI

cim:DotInstruction.generatorPerformanceDegree

Cardinality

0..1

Type

float

hourAheadSchedEnergy

HASP results.

URI

cim:DotInstruction.hourAheadSchedEnergy

Cardinality

0..1

Type

float

hourlySchedule

Hourly Schedule (DA Energy Schedule).

URI

cim:DotInstruction.hourlySchedule

Cardinality

0..1

Type

float

InstructionClearingDOT

URI

cim:DotInstruction.InstructionClearingDOT

Cardinality

1..*

Type

InstructionClearingDOT

instructionTime

The date/time for the instruction.

URI

cim:DotInstruction.instructionTime

Cardinality

0..1

Type

date

maximumEmergencyInd

True if maximum emergency limit activated; false otherwise. If unit is requested to move up to its max emergency limit., this flag is set to true.

URI

cim:DotInstruction.maximumEmergencyInd

Cardinality

0..1

Type

boolean

meterLoadFollowing

Meter Sub System Load Following.

URI

cim:DotInstruction.meterLoadFollowing

Cardinality

0..1

Type

float

nonRampRestrictedMW

Desired MW that is not ramp restricted. If no ramp rate limit existed for the unit, this is the MW value tha t the unit was requested to move to.

URI

cim:DotInstruction.nonRampRestrictedMW

Cardinality

0..1

Type

float

nonSpinReserve

Non Spin Reserve used to procure energy.

URI

cim:DotInstruction.nonSpinReserve

Cardinality

0..1

Type

float

previousDOTTimeStamp

Timestamp when the previous DOT value was issued.

URI

cim:DotInstruction.previousDOTTimeStamp

Cardinality

0..1

Type

date

rampRateLimit

The ramp rate limit for the unit in MWs per minute. Participant bidding data.

URI

cim:DotInstruction.rampRateLimit

Cardinality

0..1

Type

float

RegisteredResource

URI

cim:DotInstruction.RegisteredResource

Cardinality

0..1

Type

RegisteredResource

regulationStatus

Regulation Status (Yes/No).

URI

cim:DotInstruction.regulationStatus

Cardinality

0..1

Type

YesNo

spinReserve

Spin Reserve used to procure energy.

URI

cim:DotInstruction.spinReserve

Cardinality

0..1

Type

float

standardRampEnergy

Standard ramping energy (MWH).

URI

cim:DotInstruction.standardRampEnergy

Cardinality

0..1

Type

float

supplementalEnergy

Supplemental Energy procure by Real Time Dispatch.

URI

cim:DotInstruction.supplementalEnergy

Cardinality

0..1

Type

float

unitStatus

Output results from the case identifying the reason the unit was committed by the software.

URI

cim:DotInstruction.unitStatus

Cardinality

0..1

Type